28
INITIAL OPERATION AND TESTING (INSTALLER ONLY)
1. Open the gas and water supply valves to the water heater.
2. Check for water and gas leaks. Use soap solution to check for gas leaks.
3. To check inlet supply pressure, remove the 1/8” NPT plug on the gas inlet supply fitting just below
the bottom casing and install a barb fitting for attaching a hose to a manometer. For checking the
gas manifold pressure, the plug is located just below the gas manifold connection inside the
control panel.
4. Turn power on (after completing electrical connections – refer to Section VI, “Electrical
Connections”) and fully open a hot water tap.
5. Measure the gas pressures to see that these are within the specified limits below:
Supply Pressure:
Nat. Gas: Min.: 5 in. w.c., Max.: 10.5 in. w.c.
L.P. Gas: Min.: 8 in. w.c., Max: 13.5 in. w.c.
Manifold Pressure:
Nat. Gas: 2.0-3.3 in. w.c. High Fire, 0.5 in. w.c. Low Fire
L.P. Gas: 3.2-5.0 in. w.c. High Fire, 0.9 in. w.c. Low Fire
(High fire manifold pressures vary depending on the water
heater’s model)
6. Turn off the hot water faucets. Disconnect the electrical power to the water heater. Remove the
pressure gauges and replace the plugs. Check for gas leaks around the plugs.
7. Replace the front control panel. Restore electrical power to the water heater
NOTICE
If the gas supply pressure is below the specified value, check the gas piping to ensure that it is the
correct size for all the gas appliances on line. Check the supply pressure with all the gas appliances
in operation. The manifold pressure will vary with the water flow rate. Several hot water faucets
may need to be opened with the temperature control set on the highest setting in order to get
maximum high fire manifold pressure. If the manifold pressure is below the specified value and
there is sufficient water pressure and flow, be sure the inlet gas pressure is within the specified limits
before attempting to adjust the manifold pressure.
Summary of Contents for EverHot TG-150E-N
Page 20: ...20 Figure 6 Recommended Piping for a Basic Installation...
Page 21: ...21 Figure 7 Recommended Piping for a Circulation Systems...
Page 25: ...25 Figure 9 Recommended Piping for Combination Water and Space Heating Applications...
Page 31: ...31 Figure 11 Wiring Diagram for TG 150E N X TG 180E N X and TG 199E N X Models...
Page 32: ...32 Figure 12 Wiring Diagram for TG 237E N X and TG 237E N X A Models...
Page 51: ...51 SECTION IX PARTS LIST TG 150E TG 180E and TG 199E Models...
Page 53: ...53...
Page 55: ...55...
Page 57: ...57...
Page 59: ...59 TG 237E Models...
Page 61: ...61...
Page 63: ...63...
Page 65: ...65...
Page 70: ...70 NOTES...
Page 71: ...71 NOTES...