INSTALLATION MANUAL

SECURITY ALARM CONTROL UNIT

36-76-192

 English

EN

English

EN

Summary of Contents for Proxinet 36-76-192

Page 1: ...INSTALLATION MANUAL SECURITY ALARM CONTROL UNIT 36 76 192 English EN English EN...

Page 2: ...15 BATTERY 16 TAMPER 16 BUS RS 485 17 INPUTS 17 U1 PROGRAMMABLE OUTPUT positive 17 U2 U3 U4 Open Collector PROGRAMMABLE OUTPUTS 17 GENERAL ALARM RELAY OUTPUTS RELAY 1 RELAY 2 18 PSTN TELEPHONE LINE 1...

Page 3: ...PANISION MODULE IN THE CONTROL UNIT 33 ACQUIRING INPUT EXPANSION MODULES ON BUS 34 ACQUIRING OUTPUT EXPANSION MODULES ON BUS 35 ON BUS RADIO RECEIVER MODULE ACQUISITION 36 10 5 DEFINITION OF SYSTEM AR...

Page 4: ...ller and only the seller when upholding this right and clearly communicate any product flaws or shortcomings within two months of noticing The warranty loses validity is any user fails to communicate...

Page 5: ...and information in this manual may be changed at any time with no obligation on Brahms s part to notify anyone of this ENGLISH 4 System installation 4 1 System wiring Antenna GSM RS 232 PC Connection...

Page 6: ...s communication LEDs featured on each device should be flashing If some are not flashing this means installation or programming was wrong check cabling AIMING and programming in control unit TRADITION...

Page 7: ...ation Manual code 24805670 06 05 2013 319F80C ver 1 0 The data and information in this manual may be changed at any time with no obligation on Brahms s part to notify anyone of this ENGLISH DOUBLE BRA...

Page 8: ...ation Manual code 24805670 06 05 2013 319F80C ver 1 0 The data and information in this manual may be changed at any time with no obligation on Brahms s part to notify anyone of this ENGLISH BUS AMPLIF...

Page 9: ...fall below 12 V DC If less add an auxiliary power source and disconnect the positive while keeping the negative mutual In case of long stretches of bus always install 150 ohm resistors among terminal...

Page 10: ...her use a 1 5 mm2 section cable or a 0 5 mm2 cable plus an auxiliary power source at the end of the line as shown below CABLE RS 485 Screened 2x1 5mm 2x0 22mm twisted CABLE RS 485 Screened 2x0 5mm 2x0...

Page 11: ...4 7 kohm Yellow 4 Violet 7 Red x100 Gold 5 4 7 kohm 5 resistor The U1 output gives a positive when output is active ON 12 8Vdc The U1 output is factory programmed as TC active output with system shut...

Page 12: ...CI Types of inputs on BUS NC NA SB DB CI NC NA SB DB CI NC NA SB DB CI On board relay outputs 1 2 3 Total programmable outputs 20 36 128 Programmable control unit outputs 4 4 8 Programmable bus output...

Page 13: ...4 47 kohm temperature gauge optional PXSTB 5 Battery connection cables Respect the polarities red black 6 Central tamper 7 Line fuse for Proxinet 36 no fuse the transformer is fitted with a 130 rated...

Page 14: ...4 for Proxinet 36 NO fuse F4 for Proxinet 76 self restoring fuse 1 35 A F4 For Proxinet 192 self restoring fuse 1 35 A 8 Dip switch 1 serves to switch the control unit from operational to maintenance...

Page 15: ...the entire time the control unit is open Handling the 230 Vac main power supply cables is hazardous risk of electrecution Connect the ground via a Faston to the appposite connector Proxinet 36 Proxine...

Page 16: ...arge depending on the temperature itself Installation of the PXSTB probe without opening jumper JP1 lowers battery charge voltage by 1 Volt thus impeding recharge Respect battery polarities while conn...

Page 17: ...e chapter 4 2 INPUTS To cable the inputs see chapter 4 3 U1 PROGRAMMABLE OUTPUT positive A short circuit to the GND with active output for an extended time may lead to breakage of the protective resis...

Page 18: ...NGUAGE UPDATE BOARD PXLNG for control unit The PSTN telephone line needs to be connected to terminals L L and in output to terminals T T for switch boxes or telephones So called simulated phone lines...

Page 19: ...S PXKWD Power supply voltage 12 Vdc 15 Vdc Max power draw 60 mA Working temperature 0 40 C Relative humidity 25 75 senza condensa Dimensions HxLxD 180x120 x 28 a muro IP IP40 6 2 Card description PXKW...

Page 20: ...as not under management 13 14 15 16 Areas switched on 1 2 3 4 5 Areas being switched on 6 7 8 9 Areas switched off 10 11 12 U X P LIGHT WARNINGS LED STATUS LEGEND OF LIGHT SIGNALS When off it means th...

Page 21: ...y for at least 5 seconds KEYPAD LANGUAGE Changing the keypad menu language does not change the control unit language If you want to change the keypad menu 1 Press and hold down the key for at least 5...

Page 22: ...inserters The inserters must be mounted so as to be protected from any breaking in attempts or in an area guarded by the system contrarily the reference regulation becomes unappliccable GENERAL CHARAC...

Page 23: ...there is at least one area of scenario 3 which is in alarm mode during going out time it means that at least one input associated to scenario 3 is open status system When off it means that the associa...

Page 24: ...e NA NC SB DB and CI types power supply 9 0 16 inputs 49 56 Negative reference Fuse the same on used in the control unit to protect inputs 2 Connector to install card on control unit INSTALLING All in...

Page 25: ...DRESSING SW1 ON OFF ADDRESS Proxinet 36 Proxinet 76 Proxinet 192 SW1 ON OFF ADDRESS Proxinet 36 Proxinet 76 Proxinet 192 ON 1 0 not valid not valid not valid ON 1 8 Inputs 65 72 ON 1 1 Inputs 5 12 Inp...

Page 26: ...oltage 12 Vdc 15 Vdc Max power draw 100 mA Working temperature 0 40 C Relative humidity 25 75 without condensation Operating frequencies 868 MHz and 433 MHz Dimensions 110 x 80 x 30 mm IP IP20 FEATURE...

Page 27: ...S 485 bus terminals for connecting keypads remote modules and inserters power supply to bus A B data 2 BUS red LED light for bus communication signaling If flashing it means that the module is communi...

Page 28: ...aller not registered with GSM network GSM dialler is properly registered with GSM network 0 5 s ON 0 5 s OFF 0 3 s ON 2 7 s OFF INSTALLING All interface insertion and removal operations must be made w...

Page 29: ...UNIT POWER ON Power up the control unit with 230 Vac and connected the battery When first switched on the control unit follows the configuration of the POWER ON CENTRALE parameter which is normally s...

Page 30: ...CODES INSTALLER S TECHNICAL CODE access to the technical menu may be either preceeeded or not by the User code Simultaneously accessing the technical menu or user from multiple keypads is not allowed...

Page 31: ...ON OFF EXACT 2 GOING TO BED 1 3 TURN ON OFF EXACT 3 STAYING INDOORS 3 TURN ON OFF EXACT KEYPADS ASSOCIATED SCENARIOS INSERTERS ASSOCIATED SCENARIOS ALL KEYPADS A GOING OUT ALL INSERTERS L1 GOING OUT...

Page 32: ...ed example of added keypad 2 For the other keypads follow the steps in order STEP 1 Keypad addressing 1 From a properly bought keypad usually keypad 1 2 Enter user code if less than 6 characters confi...

Page 33: ...e addressed 4 Using a key even one that you have not bought approach the inserter to which you wish to assign the address which appears on the display and wait for the LED lights to flash slowly and f...

Page 34: ...sion modules on bus with same address All expansion modules are made with address 2 and the control units have no factory activated expansion To set up control unit for expansion you need to STEP 1 Ad...

Page 35: ...ess technical menu 3 With select SYSTEM and press 4 With select EDIT SYSTEM and press 5 With select OUTPUTS MODULE 6 Press the number key for the expansion address which you need to activate by adding...

Page 36: ...ess than 6 characters confirm with 2 Enter technical code to access technical menu 3 With select SYSTEM and press 4 With select MODIFY SYSTEM and press 5 With select RADIO MODULES 6 Press the number k...

Page 37: ...ich you need to activate by adding activated deactivated 7 Press to output and return to the previous menus STEP 2 Modify description of areas 1 Staying within the Technical Menu 2 With select AREAS a...

Page 38: ...s the action you want on the areas switching on off 1 Staying within the Scenarios Menu 2 With select ACTION ON AREAS 3 With set the parameter to TURN ON OFF EXACT It is the classic scenario we will u...

Page 39: ...2 With select DESCRIPTION and press 3 Use the alphanumeric keys to edit text 4 Press to confirm and return to previous menus Press to cancel the change DESCRIPTION XX SCENARIO XX SCENARIO XX OK ESC G...

Page 40: ...associate the scenario to 7 With you can set the scenario to launch NO to deactivated the key 8 Press to output and return to the previous menus 08 23 16 05 10 ENTER CODE 123456 COMMAND WAITING USER...

Page 41: ...launch NO to disable the LED light 7 Press to output and return to the previous menus 08 23 16 05 10 ENTER CODE 123456 COMMAND WAITING USER MENU 222222 INSERTERS 06 EDIT INSERT 01 INSERITORE 01 SCENAR...

Page 42: ...XXX INPUT XXX STATUS XXX INSERTED TYPE XXX ISTANTANEOUS BALANCING XXX SINGLE BALANCE AREAS XXX DESCRIPTION XXX INPUT XXX SCENARIO XX OK ESC GOING OUT OK ESC Example Let s say we have the following sy...

Page 43: ...completely switched on U3 System ready yields a negative if all inputs are closed U2 System status yields a negative is at least one area is switched on U4 Yields a negative when something is out of...

Page 44: ...TYPE REPETITIONS ALARM SABOTAGE TECHNICAL BURGLARY SWITCHING ON SWITCHING OFF OUT OF ORDER CODE ENTERING KEY ENTERING VARIOUS COMMON MESSAGE 1 7 VOICE 2 x x x x 1 8 14 SMS 1 x x 1 15 CONTACT ID 1 x x...

Page 45: ...t the telephone calls in the following way with PSTN priority Dad 348xxxxxx1 make VOICE call due to sabotage alarm events send SMS due to malfunctions Mom 348xxxxxx2 make a VOICE call due to sabotage...

Page 46: ...Open the programming window for the control unit 3 Check the Voice messages item 4 Starting programming 5 If parameter PROGRAMMING FROM PC is WITH CONTROL UNIT OFF launch programming AFTER USER CODE b...

Page 47: ...OFF NO ACTIVATED Cleaning firm ALL SWITCHING ON ONLY NO NO Access control NO SWITCHING ON ONLY NO NO 10 12 Acquiring Keys Because the keys are univocal from the factory there are no activated keys in...

Page 48: ...ending on the User type Application example AREAS ASSOCIATED AUTHORISATION Owners employees ALL SWITCHING ON SWITCHING OFF Cleaning firm ALL SWITCHING ON ONLY Access control NO SWITCHING ON ONLY Examp...

Page 49: ...technical menu 3 With select SYSTEM and press 4 With select SYSTEM TEST and press 5 With select the parts of the system you wish check and press 6 Press to output and return to the previous menus 08 2...

Page 50: ...ng software onto your PC 2 Connect the control unit to the PC via a RS 232 standard cable direct male female or via a USB RS232 cable STEP 4 PC setting to do only once 1 Set the control unit access pa...

Page 51: ...menu 2 Place the control unit into operational mode by lowering micro switch 1 3 Shut down the control unit 4 Exit the technical menu 12 Restore system Restoring parameters is irreversible and cancels...

Page 52: ...stem status INITIALIZATION INITIALIZATION RUNNING 12 2 Factory settings the default parameters don t delete codes or keys already in memory To delete this items it s necessary to enter in the specific...

Page 53: ...Installation Manual code 24805670 06 05 2013 319F80C ver 1 0 The data and information in this manual may be changed at any time with no obligation on Brahms s part to notify anyone of this ENGLISH No...

Page 54: ...54 Installation Manual code 24805670 06 05 2013 319F80C ver 1 0 The data and information in this manual may be changed at any time with no obligation on Brahms s part to notify anyone of this ENGLISH...

Page 55: ...021 1 Terminal Equipment Te Attachment Requirements For Pan European Approval For Connection To The Analogue Public Switched Telephone Networks Pstns Of Te Excluding Te Supporting The Voice Telephony...