background image

BOXLIGHT PRO80S3 Projector Preliminary User’s Manual 

Page 25 of 33 

 

3.3

 

Enhanced Color Correction (P7) Commands 

 

 

 
ECC 

    Select 

P7 

TARGET 

DATA 

    ECC 

 

Select the Target Color Data. This command takes a parameter – the target index – between 0 and 13. The following table 
lists the GRBW CIE color coordinates for the selected ECC index. Note that indicates 1 through 9 do not specify the 
Magenta, Cyan or Yellow CIE values. Indices 10 through 13 specify user-definable tables which may include the CMY 

coordinates as well as GAIN values for each of the colors and WHITE. See TI document – 

Product Specification for 

DDP1000, DDP1010, DDP1011 Based Modular Formatter Component Set [Dwg #2503986, Rev. J or later] for details. 

 

Target Color Gamut Data 

GREEN RED  BLUE WHITE 

Index Description 

X Y X Y X Y X Y 

0 OFF 

ECC OFF 

ANSI - 3200°K 

.423 .399 

ANSI - 5400°K 

.335 .349 

ANSI - 6500°K 

.313 .329 

ANSI - 9300°K 

.210 .710 .670 .330 .140 .080 

.283 .297 

EE-REC709 

EE-XYZ 

User 2 

User 3 

N/A 
N/A 

User Selectable GREEN, RED, BLUE, MAGENTA, CYAN, 

YELLOW and WHITE CIE Indices stored in EEPROM 

(See TDNLD) 

Native 

.316 .651 .655 .341 .147 .044 .296 .337 

 
Syntax: ecc {target index} 

 
> ecc2 
EC Set Index 2 

ECC Enable 
Freeze Frame On 
Freeze Frame Off 

 

 

 

MDNLD 

    Download 

Measured 

Color 

Gamut 

Data 

    MDNLD 

 
Download Measured Color data for storage on the BLUE Formatter’s EEPROM. When the command is entered, the 

operator is prompted to send 16 bytes of data: the X and Y CIE coordinates of the un-enhanced GREEN, RED, BLUE and 
WHITE colors. Each coordinate is 16 bits - 2 bytes - sent least significant byte first in hexadecimal. For each coordinate, 

first multiply by 65536 and convert to hexadecimal. Output two hexadecimal bytes, LS byte first, for each of the 8 
coordinates in order: Gx, Gy, Rx, Ry, Bx, By, Wx, Wy , Bx By ,WY and BY. The values can be manually typed from the 
terminal or stored in a file and sent to the controller board using the terminal’s “Send Text File” utility. Characters typed of 

sent will NOT be echoed. The 16 bytes sent may be <SPACE>, <TAB>, <CR> or <LF> separated. 
 
After the data is downloaded, the coordinates will be displayed in decimal format for confirmation. 

Summary of Contents for PRO80S3

Page 1: ...l BOXLIGHT PRO80S3 Projector User s Manual For Controller Firmware Revision 0 73 and Motor Control Firmware Revision 2 0 7 July 2008 BOXLIGHT Inc NE 151 Highway 300 Suite A PO Box 2609 Belfair WA 9852...

Page 2: ...in C 9600 8 N 1 Film Projector Lockout Connector RJ 45 NIC Switch 2 position Rocker Switch Located just about the power connector System Power ON OFF 3 position Rocker Switch Soft Power ON OFF and Shu...

Page 3: ...the left side of the rocker switch will cause the SHUTTER to close and the formatters to go to CURTAIN MODE and also initiates a 5 MINUTE POWER DOWN cycle During this time the lamp fans and formatter...

Page 4: ...he NIC interface The NIC card controls a multiplexed that switches the UART between these two sources The controller firmware services three different command sets one from the NIC card which is not s...

Page 5: ...tails 1 8 Lamp Module Replacement High pressure lamp may explode if improperly handled Refer servicing to qualified service personnel The customer should never attempt to disassemble the lamp or to di...

Page 6: ...BOXLIGHT PRO80S3 Projector Preliminary User s Manual Page 6 of 33...

Page 7: ...BOXLIGHT PRO80S3 Projector Preliminary User s Manual Page 7 of 33...

Page 8: ...cause the projector to overheat cause component failure or even catch on fire The filter should be replaced when clogged or when 10 000 hours of use has occurred Contact the dealer to order a new filt...

Page 9: ...BOXLIGHT PRO80S3 Projector Preliminary User s Manual Page 9 of 33 STEP 2 Lower the cover...

Page 10: ...BOXLIGHT PRO80S3 Projector Preliminary User s Manual Page 10 of 33 STEP 3 Remove the filter STEP 4 Install the new filter replace the filter cover and insert the 2 screws...

Page 11: ...BOXLIGHT PRO80S3 Projector Preliminary User s Manual Page 11 of 33 1 10 Remote Control Key...

Page 12: ...at the last command the exclamation point is not echoed If ANY characters are sent between the prompt and the even a CR the previous command will be lost and cannot be repeated using the option just r...

Page 13: ...image to the LEFT FFn Move FOCUS away from Projector FOCUS FAR FNn Move FOCUS toward Projector FOCUS NEAR Rn Move image to the RIGHT Un Move image UP ZIn ZOOM IN Projected Image Smaller ZOn ZOOM OUT P...

Page 14: ...receded by OFF Main Power Shutdown ON Main Power ON ONS Main Power ON and Start Signal Lamp mode OND Main Power ON and Start Dual Lamp mode OPEN Open Shutter and put Formatters in Normal Projection Mo...

Page 15: ...y the FORMATTER Register Help Table FR Read Register from ALL Formatters FRB Read BLUE Formatter Register FRG Read GREEN Formatter Register FRR Read RED Formatter Register FW Write Register to ALL For...

Page 16: ...nges in image position focus or size The last numeric character of the command determines period the motor is energized with 0 being the shortest and 3 the longest Due to backlash in the motor drive a...

Page 17: ...ntrast Increment Upper Level R G B Contrast 02 02 02 CTRL N Cycles through the Projection modes CURTAIN CTRL O Cycles through the Projection orientations FRONT REAR CEILING etc REAR CEILING CTRL P Cyc...

Page 18: ...er one or no parameters In lockout mode the film projector interlock circuitry senses current in the External Interlock connector that is attached to the Feature Film Projector The lockout when active...

Page 19: ...during setup or testing a terminal must be connected to the serial interface and serial commands fpol ir etc must be issued The projector can be returned to power control mode with fpol 2 Syntax fpol...

Page 20: ...OWER MODE SETP GETP GETP OSRAM Lamp support change lamp Output power The output wattage of the lampdriver can be adjusted by command SETP is used to setup the lamp output wattage For now user can adju...

Page 21: ...F lampon1 LAMP1 ON lampon2 LAMP2 ON M M Informational Message Reporting Control M M Syntax m m m Monitor Info On m Monitor Info Off ON OFF ONS OND POWER Control ON OFF ONS OND Power sequencing command...

Page 22: ...Main Power On and Turn On Single lamp mode which lifetime is small then the other one OND Main Power On and Turn On Dual lamp on Power On Dual_Lamp Lamp1 S N feng1 Lamp1 Time 9 21 Lamp1 Strikes 45 Lam...

Page 23: ...face When VERBOSE is enabled all messages informational error and status etc are sent as human readable text When disabled those messages are sent as a 6 character ASCII group There are two types of m...

Page 24: ...e 89 Ballast OVERTEMP Shutdown 8A Lamp Extinguished After Power up try Restrike 8B Resetting Formatters usually non critical 8C LAMP SYNC Signal Inactive usually non critical 8D LAMP SYNC Detected usu...

Page 25: ...N A N A User Selectable GREEN RED BLUE MAGENTA CYAN YELLOW and WHITE CIE Indices stored in EEPROM See TDNLD 9 Native 316 651 655 341 147 044 296 337 Syntax ecc target index ecc2 EC Set Index 2 ECC En...

Page 26: ...0 350 BLUE 140 033 WHITE 290 330 RDTCGD Display Target Color Gamut Data RDTCGD Display the Target Color Gamut Data for the specified index This command takes a parameter the target index between 1 and...

Page 27: ...te is the first value sent The command description only defines bytes 2 through 140 a total of 139 Add an extra 0 byte to the end so that full 140 bytes are sent Unspecified parameters such as GAIN va...

Page 28: ...rate on the terminal programmed will have to be changed to continue This command also sets the BAUD clock that will be set at start up Syntax baud 9600 19200 FH FORMATTER Register Help FH This comman...

Page 29: ...a 63 RW Enhanced Color Corr Disable FR FRR FORMATTER Register Read FR FRR FRG FRB FRG FRB Read formatter registers FR Read all formatters FRR Read RED formatter FRG Read GREEN formatter FRB Read BLUE...

Page 30: ...en lsb 3 Green msb 4 Red lsb 5 Red msb 6 Blue lsb 7 Blue msb 8 Protocol Pad Thus three words are required To write the following data to the BLUE formatter BRIGHTNESS register Green 148416 Red 18E016...

Page 31: ...uires data to sent those bytes are appended to the command hexadecimal and space delimited If the command causes the ballast to return data no just echo the command the response will be output in hexa...

Page 32: ...as OPEN FREEZE 8C73718E16 Close Shutter same as CLOSE Control buttons other than those listed in BOLD above generate no activity 4 1 Pan Zoom and Focus Speed and Nudge Functions The Pan Zoom and Focu...

Page 33: ...ck presses followed by a hold Motor speeds are determined by the number of quick button presses up to three before holding the button down H very slow PH slow PPH medium PPPH fast PP PH fast Release t...

Reviews: