Air Filter

Cleaning the air Filter

The air filter should be cleaned as described below at intervals of approximately 100 hours.

1. Switch the projector power supply OFF, and remove the power cord from the power outlet.
2. Clean the air filter with a vacuum cleaner.

Other Maintenance

Maintenance Inside the Equipment

For safety reasons, ensure that the equipment is cleaned and checked by BOXLIGHT once every
two years. Maintaining the equipment by yourself is dangerous.

Cleaning the Lens

Gently wipe the lens with lens cleaning paper. Do not touch the lens with your hands.

Cleaning the Cabinet and Remote control transmitter

Gently wipe with a soft cloth. If dirt and stains etc. are not easily removed, use a soft cloth
dampened with water, or water and a neutral detergent, and wipe dry with a soft, dry cloth.

CAUTION • Switch power OFF and remove the power cord from the power
outlet before beginning maintenance work. Please read the separate “SAFETY

INSTRUCTIONS” thoroughly to ensure that maintenance is performed correctly.
• Do not use detergents or chemicals other than those noted above (e.g. benzene
or thinners).
• Do not use cleaning sprays.
• Do not rub with hard materials, or tap the equipment.

CAUTION • Switch power OFF and remove the power cord from the power
outlet before beginning maintenance work. Please read the separate “SAFETY

INSTRUCTIONS” thoroughly to ensure that maintenance is performed correctly.
• Replace the air filter if contamination cannot be removed, or if it is damaged.
Contact BOXLIGHT for service. For the optional air filter, see the item “Optional
Parts” of the Table 12. 
• Do not use the equipment with the air filter removed.
• When the air filter is clogged with dust etc. the power supply is switched OFF
automatically to prevent the temperature rising inside the projector.

Replacing the Air Filter

Replace the air filter if contamination cannot be removed, or if it is damaged.

1. Remove the filter cover.
2. Remove the old filter.
3. Set the new filter and the filter cover.

Summary of Contents for CP-635i

Page 1: ...entamente il manuale d sitruzioni in modo tale da poter comprendere quanto riportato ai fini di un corretto utilizzo del proiettore MANUAL DE USUARIO Lea cuidadosamente este manual del usuario para po...

Page 2: ...le 9 OSD Message 20 Table 10 Indicators Message 21 Table 11 Symptom 22 Table 12 Specifications 23 For TECHNICAL and REGULATORY NOTICE see the end of this manual The information in this manual is subje...

Page 3: ...nderstanding BEDIENUNGSANLEITUNG Bitte lessen Sie diese Bedienungsanleitung zugunsten der korrekten Bedienung aufmerksam MANUEL D UTILISATION Nous vous recommandons de lire attentivement ce manuel pou...

Page 4: ...Air Filter and Intake for the Cooling Fan Rear Foot Adjuster INPUT Button LAMP Indicator TEMP Indicator POWER Indicator RESET Button MENU Button Ventilation Openings exhaust REAR RIGHT VIEW OF THE PRO...

Page 5: ...disassemble the remote controller NOTE These functions work when the mouse control function is activated Remember the POSITION VOLUME KEYSTONE BLANK ON and MENU ON functions disable the mouse control...

Page 6: ...ttery holder of the remote controller with protection film the transparent film some of which is inside the battery holder Pull out the protection film to load the battery Replacing 1 See the reverse...

Page 7: ...to the screen 10 Table 1 Installation Reference a CAUTION Install the projector in a suitable environment according to instructions of the accompanying manual SAFETY INSTRUCTIONS and this manual When...

Page 8: ...ay have to be used with the core set to the projector side Use the cables which are included with the projector or specified Cabling Refer to the table below for connecting each terminal of the projec...

Page 9: ...al equipment including a computer display and an operating system This projector is recognized as a plug play monitor Use the standard display drivers Plug play may not operate by the computer to conn...

Page 10: ...ndby mode when cooling is complete and the POWER indicator ceases blinking and changes to orange Check that the indicator is orange and set the power switch to O 3 The POWER indicator is extinguished...

Page 11: ...e with a video signal is input After approximately 10 seconds of inactivity the icon is extinguished and the POSITION mode is cleared automatically and buttons may operate as the mouse control button...

Page 12: ...ly 10 seconds of inactivity MENU SELECT Select Menu Type Press the MENU SELECT button Allows the user to select the normal menu or the single menu Only the selected item is displayed on the single men...

Page 13: ...E COLOR BAL R COLOR BAL B ASPECT 0 1 1 0 0 0 SETUP INPUT OPT IMAGE Table 4 Setup Menu Item Description RGB VIDEO S VIDEO COMPONENT 480i 575i 480P 720P 1080i BRIGHT Dark Light CONTRAST Weak Strong V PO...

Page 14: ...ly with some input signals Pressing the AUTO button in this case may correct this problem This function is the same as for the AUTO function in Basic operation RGB Displays RGB Input Frequency Display...

Page 15: ...en Color Select color with the button The image is cleared and the entire screen is displayed in the selected color when BLANK mode is set with BLANK ON or when there is no signal for 5 minutes MIRROR...

Page 16: ...OFF Set AUTO OFF Set 1 99 minutes with the button The system automatically enters the standby mode when a signal is not received for the set time Clear AUTO OFF Select STOP 0 min with the button When...

Page 17: ...ed color MIRROR Select Mirror Status Select the mirror status with the button START UP Setup Initial Screen Display Select the TURN ON with the button Clear Initial Screen Display Select the TURN OFF...

Page 18: ...e the lamp can leak out of the projector s air vent Handle the lamp with utmost care as it can burst during use if subjected to a shock or impact or if scratched or cracked Probability for the burst w...

Page 19: ...he Lamp Timer Reset the lamp timer after replacing the lamp When the lamp has been replaced after the LAMP indicator is red or the CHANGE THE LAMP message is displayed complete the following operation...

Page 20: ...h CAUTION Switch power OFF and remove the power cord from the power outlet before beginning maintenance work Please read the separate SAFETY INSTRUCTIONS thoroughly to ensure that maintenance is perfo...

Page 21: ...r The usage time of lamp is about to reach Power will be switched OFF in a few minutes 2 Switch power OFF immediately and replace the lamp as shown in P 17 18 Lamp Always reset the lamp timer after re...

Page 22: ...ks Lights red Blinks red Turns off Lamp or lamp cover is not found or hasn t been fitted in correctly Switch power OFF and wait for 45 minutes until the equipment cools Check fitting of the lamp and l...

Page 23: ...orrectly set Use the projector or remote control transmitter to set 10 No signal input Connect correctly 7 8 Video is present but no audio The projector is not correctly connected Connect correctly 7...

Page 24: ...c TTL level D sub 15 pin shrink jack 2 AUDIO IN 1 200mVrms 50 k max 3 0Vp p Stereo mini jack 2 Video signal input VIDEO IN 1 0Vp p 75 terminator RCA jack S VIDEO IN Brightness signal 1 0Vp p 75 termin...

Page 25: ...Product WARRANTY LIMITATION AND EXCLUSION BOXLIGHT CORPORATION shall have no further obligation under the foregoing limited warranty if the Product has been damaged due to abuse misuse neglect acciden...

Page 26: ...Printed in Japan QR53221...

Reviews: