Bowflex
®
TreadClimber
®
Service Manual
1.0 - REPLACEMENT oF AC INLET
Tools Needed:
• Phillips Screwdriver
NOTE: If using a powered driver, it must be on the
“LOW TORQUE” setting, otherwise it will
strip screws.
1-1 Unplug machine from wall outlet and remove AC
plug from front of machine.
1-2 Wait 5-minutes after unplugging machine
to ensure there is no residual power before
performing replacement.
1-3 Remove front base plastic cover (4 screws). Make
sure locking mechanism latch is unlatched from
the front faceplate (see Figure 1 and 2).
1-4 Unscrew front faceplate (3 screws).
1-5 Carefully, pull faceplate towards you so that you
can see all three wires (see Figure 3).
1-6 Remove AC inlet from wires and remove old inlet
from faceplate and replace with new one.
1-7 Insert wires into new inlet making sure
connections are correct (from front of plate: white
- top left, black - top right, green - bottom).
1-8 Replace faceplate and front plastic.
1-9 Recalibrate machine according to Appendix 3.
AS LoNG AS THE TREADCLIMBER® FITNESS
MACHINE IS PLuGGED INTo A PoWERED ouTLET
AND THE PoWER SWITCH IS oN, THE uNIT IS
RECEIvING PoWER, EvEN IF THE DISPLAY IS
TuRNED oFF. ALWAYS uNPLuG THE PoWER CoRD
FRoM THE ouTLET AND WAIT 5-MINuTES BEFoRE
PERFoRMING REPAIRS oR MAINTENANCE.
7! 2 . ) . '
! 4 4 % . 4 ) / .
$ ! . ' % 2
)--%$)!4%!#4)/.2%15)2%$
# ! 5 4 ) / .
mechanical service guide
Figure 1:
Figure 2:
Figure 3:
Front Faceplate
Front Base Plastic Cover