TroubleshooTing flowcharTs

Dumbbell Knob will Not Lock when out of Base

12/1/2003

ND-552

SelectTech Dumbbell

Trouble Shooting

Dumbbell Knob Will Not

Lock When Out Of Base

Nautilus Health & Fitness Group

Explanation: 

The SelectTech Dumbbell features a locking mechanism that will automatically lock the

adjustment knob and keep it from rotating when the dumbbell is removed from the base.  This will ensure

that the weight plates will not be “de-selected” causing a plate to drop out.  It is very important this

mechanism function correctly.

Problem:

 User is able to rotate the handle when dumbbell is removed from the base.

The following information will help you determine what may be causing the problem, how to resolve it

and to return the unit to proper functioning condition.

With the dumbbell handle sitting in the base, select 5 lbs on

each adjustment knob.  Remove the dumbbell handle from

the base.  No plates should be attached at this time.  With

the dumbbell out of the base attempt to rotate one of the

adjustment knobs, repeat step for the other side

Knob will rotate

Replace Handle

Return handle to Nautilus for inspection

Knobs will not rotate

With thumb or forefinger manually

depress the plungers on the bottom of

the dumbbell.  Do not rotate the

adjustment knobs while depressing the

plunger.  Depress and release the

plungers several time each.  Confirm that

the plunger will depress and

automatically return with a smooth

operation

Plunger will not operate smoothly or is sticking

Plunger seems to operate correctly

With the handle returned to the base, turn the adjustment knobs to the 7.5 lbs

setting.  Carefully pick up the dumbbell no more than two inches.  Attempt to turn

both of the knobs while the dumbbell is elevated from the base.  The knobs should

not turn on either side.  Carefully repeat this step for each weight setting  on each

side.  Do not attempt this test with the dumbbell elevated above the base more

than two inches when it is set to 7.5 lbs or more.

Knob rotated during test

Handle operating correctly

Knobs did not rotate at any setting

Summary of Contents for 1090 DUMBBELLS

Page 1: ...220 552 1090 DUMBBELLS and BDS1642 BDS552 STAND Service Manual Patent 6 422 979 other USA and Foreign Patents Pending PN 001 6872 Rev B 03 2007...

Page 2: ...el will result in voiding of the warranty If you are a consumer and require technical support to resolve a problem with your Bowflex SelectTech Dumbbell Set please call Nautilus Customer Service at 80...

Page 3: ...ooting BD220 552 AND1090 Dumbbell Troubleshooting Guide BD220 520 and 1090 Dumbbell 4 Troubleshooting Guide BDS552 and BDS1642 2 1 stand 5 Troubleshooting Flowcharts 7 Reference Images Damage 13 Refer...

Page 4: ......

Page 5: ...gers under the age of 18 must always have parental supervision and instruction on the use of this product 4 Inspect the dumbbells prior to each use Do not use a dumbbell with worn or damaged parts 5 P...

Page 6: ...ifications BD552 Dumbbell Assembly Footprint WEIGHT 58 LBS 26 4 KG 153 4 9 8 BD1090 Dumbbell Assembly Footprint WEIGHT 98 lbs 44 5 kg 17 5 10 9 5 BD220 Dumbbell Assembly Footprint WEIGHT 55 12 LBS 25...

Page 7: ...Product specifications 7EIGHT 0LATE 3ELECTION 4ONGUE...

Page 8: ...ted those plates remaining in the dumbbell base are in their correct spots and have not been moved to a different support slot This may be blocking the dumbbell from fitting back into the base 3 See s...

Page 9: ...or Adjustable Wrench Steps 1 1 Unscrew the Towel Bar 9 from the Dumbbell Platform 7 8 Set the hardware safely aside 1 2 Unscrew the Dumbbell Platforms 7 and 8 from the stand Legs 1 Set the hardware f...

Page 10: ...be on the left hand side and the R sticker should be on the right hand side However the platforms may be mislabeled or the stickers may be missing 1 4 Attach the Towel Bar 9 to the Dumbbell Platforms...

Page 11: ...on a NDCS 552 Stand YES Rotate dumbbell 180 degrees on stand Confirm that rubbing still occurs Sometime base orientation will resolve rubbing and may be acceptable solution for customer NO YES Check t...

Page 12: ...he following steps will help determine if the test is being performed correctly to identify if the dumbbell is performing to specifications and if there is a problem what might be causing it TEST PROC...

Page 13: ...andle YES Carefully pull on the weight plate s that were lifted with the handle they should not be attached to the handle you should be able to pull them free Reinstall the removed plates back into th...

Page 14: ...mething out of position in the assembly that is causing the interference Problem User cannot rotate the adjustment knob when the handle is in the base with weight plates The following information will...

Page 15: ...t this time With the dumbbell out of the base attempt to rotate one of the adjustment knobs repeat step for the other side Knob will rotate Replace Handle Return handle to Nautilus for inspection Knob...

Page 16: ...nstall the handle so that the adjustment knobs are now on the other side of the dumbbell Repeat first test to see if smallest plate is still incorrectly selected on the same side of the dumbbell as be...

Page 17: ...ly apply some pressure to all the selection collars while looking for any damage as illustrated in the images above It is important to apply some pressure to each selection collar parallel to the dumb...

Page 18: ...ecome loose or is not fully tightened at the factory the customer can tighten this themselves It is critical that the customer not remove BOTH screws from the covers on the handle assembly There is a...

Page 19: ...event be liable for incidental or consequential losses damages or expenses in connection with its exercise products Nautilus Inc s liability hereunder is expressly limited to the replacement of goods...

Page 20: ...ax 800 898 9410 CORPORATE HEADQUARTERS Nautilus Inc World Headquarters 16400 S E Nautilus Drive Vancouver Washington USA 98683 Phone 800 NAUTILUS INTERNATIONAL CUSTOMER SERVICE SWITZERLAND OFFICE Naut...

Page 21: ...e visit www Nautilus com 2005 Nautilus Inc All Rights Reserved Nautilus Bowflex the Bowflex lgog and SelectTech are either registered trademarks or trademarks of Nautilus Inc Nautilus Inc World Headqu...

Reviews: