BOVIAR T-TEST K12 User Manual Download Page 9

 

 

User manual 

 T-TEST K12 

   

Vers. 

EN-02_18  AVC

            

Date: 

 (IT 27_07_13 ver. 2 AM)

 

 

- 9 - 

Connecting sensors   

  

 
 

1.

 

Displacement Sensors 

(Potentiometer type min. 1K)

 

 

Front panel sockets - Channels 

1 to 12

 

Extension cable requested Cod. CPR4005/mt 

 
 

 

2.

 

Load cell / Pressure transducer  

                 Supply  

 

 12 .. 24 Vdc 

                 Output     

           4 .. 20 mA 2-wire 

 

 

Front panel socket - Channel 

Load

 

Extension cable requested Cod. CPR4018/mt 

 
 

3.

 

Temperature Sensor / Aux 4-20 mA 

 

Front panel socket - Channel 

Temp

 

For temperature sensor Type NTC 10K 
Extension cable requested Cod. CPR4005/mt 
 

The adapter included in the supply allows to use this channel as an additional input for 
a further 4..20mA sensor.  

Extension cable requested Cod. CPR4018/mt 
 

 
 
 
 
 
 
 

 
 

 

Summary of Contents for T-TEST K12

Page 1: ...I IE E EL L LD D D D D DA A AT T TA A A A A AC C CQ Q QU U UI I IS S SI I IT T TI I IO O ON N N S S SY Y YS S ST T TE E EM M M f f fo o or r r l l lo o oa a ad d d t t te e es s st t ti i in n ng g g...

Page 2: ...sale Should you need any clarification or assistance please contact our Technical Service at Boviar 00 39 081 7583566 info boviar com We thank you for your choice and wish you a nice work with the eq...

Page 3: ...tallation 12 Control Panel 13 Function 13 Buttons description 13 Connection 16 Scanning 17 Configuration Panel 18 Function 18 Buttons Description 18 Accessing Configuration Panel Pannello Configurazio...

Page 4: ...cal system is being used to apply the load to the structure under test Yet it is also possible to manually enter applied load data which will be graphically displayed as well A rechargeable in built 6...

Page 5: ...Connector socket Displacement sensors sockets 12 nos Additional sockets for Temperature sensor NTC AUX 4 20 mA sensor Load Pressure sensor 4 20mA Status LEDs Battery charge status Socket for optional...

Page 6: ...Interface Half Duplex RS485 serial 9600 to 115200 bps 16 bit Converter Resolution 16 bit 1LSB with operating range 10mV to 2 5V Sensors supply 2 5V for displacement transducers 12 15V for load cell p...

Page 7: ...ert for battery about to exhaust o Red battery exhausted recharge or connect external power For longer exercise time or any special needs you can use the charger adapter supplied as standard and conne...

Page 8: ...es in fire or place them near heat sources Pay attention not to let positive and negative poles to come in contact with metal objects Never shortcircuit them Never try to recharge batteries that are N...

Page 9: ...Pressure transducer Supply 12 24 Vdc Output 4 20 mA 2 wire Front panel socket Channel Load Extension cable requested Cod CPR4018 mt 3 Temperature Sensor Aux 4 20 mA Front panel socket Channel Temp For...

Page 10: ...s 6V Battery and relevant charger 485 USB cable for connection to PC USB 6015 2 485 USB extension cable Length 10 m Cod 485 6012 10 Cable with alligator clips Cod PWR 001 2 for connection to an extern...

Page 11: ...el This panel is used to display the system parameters these ones cannot be modified by the users such as firmware version ID and serial number of the unit and also to set the sensors parameters as Na...

Page 12: ...S perform this procedure as Administrator Follow the prompts suggested during installation operations A message will finally confirm that the operation has been successfully accomplished Insert the U...

Page 13: ...he T TEST K12 unit Once connected it will be possible to access all other commands and panels Figure 2 Control Panel First launch Buttons description The Fig 2 above shows two groups of buttons on the...

Page 14: ...Controllo Control Panel Sistema System Hardware Gestione Periferiche Device Manager Porte Com and LPT Profilic to USB Com Connection Status LEDs Red Disconnected from T TEST Flashing Yellow Green Con...

Page 15: ...rresponding button the SCAN function will be activated and the unit configuration will be displayed as below Figure 5 Map Area If you explode the single knot channel by clicking the relevant box of th...

Page 16: ...ng please check that The unit is powered Switch to ON PC and T TEST K12 are connected The correct COM port number is selected Press the Connessione control and in a few seconds you will be connected t...

Page 17: ...nd you can easily access the different functions available Scanning Use this function by clicking the corresponding button see Linea group controls in order to read the configuration data of the T TES...

Page 18: ...t parameters Versione Identifies the firmware on board Seriale Serial number of the unit Identificativo Brand name of the unit T TEST K12 No user s modification accepted Sensori Sensors Parameters Con...

Page 19: ...the unit is delivered with a configuration according to the type of sensors as specified in the client s order It is strongly recommended that such a configuration is saved before any modification is...

Page 20: ...sensor being used e g mm C KN mA Proceed as above for the remaining sensors channels Note Channels 1 to 12 i e Canale 0 to Canale 11 being part of the same type of measurement will all have the same I...

Page 21: ...discuss such details For manual calibration procedure the calibration certificates normally supplied with the measuring sensors are used The calibration table of the T TEST K12 accepts up to ten calib...

Page 22: ...measurement 50 mm and confirm by pressing Invio Enter Do the same to enter any further calibration point A calibration is effective only when at least two points are entered in the table Repeat the o...

Page 23: ...uration Double click OK to confirm you wish to the upload the selected configuration file which will be displayed soon after as per Fig 10 Note It is necessary to send the new data as displayed to the...

Page 24: ...EN 02_18 AVC Date IT 27_07_13 ver 2 AM 24 Acquisition Panel Function This panel is meant to set the preliminary details for the new test being started as well as running and monitoring the test itsel...

Page 25: ...omatica in case a load or pressure sensor is available and connected to the TTEST K12 LOAD socket Misura Measurement from the drop down list choose the preferred mode for each of the following 1 Senso...

Page 26: ...provided that at least one displacement sensor and the load sensor have been set as active regardless if manual or auto their respective buttons are now enabled for a new test Note Before selecting th...

Page 27: ...Displacement Load diagrams Tests can be started by using either options of the start buttons in Fig 15 Immediato Prompt Start in such a case the saving data procedure will begin immediately and the p...

Page 28: ...ad axis Y2 100 4 Additional sensor axis Y3 100 Note The setting parameter of Y2 and Y3 scales is no absolute value but a multiplier of Y1 displacement axis Fig 17 Prompt Start Differito User controlle...

Page 29: ...lied to the structure under testing and press INVIO This value will be displayed at LOAD axis and stored in the PC memory Annotazione Notes Here you can write down any significant note you may wish as...

Page 30: ...lled and correctly working before a test is started Figure 19 Measurement Panel Select the sensor to be checked by pointing it with your mouse and then clicking left The chosen sensor s line will turn...

Page 31: ...irectional aerial with connector Installation Connect the first Radio Module to the PC via the USB cable supplied The system will start searching the driver of the device just connected Direct the sea...