Manual Current relay print JGA2011 

 

Boutronic B.V. 

Boutronic B.V. 

Page - 9 - 

 

s-Gravenzande The Netherlands 

Measurements

 

38,0 mm

25,0 mm

7,5 mm

Top hat rail IEC/EN 60715

90,0 mm

62,0 mm

44,0 mm

2

6

,0

 m

m

4

7

,0

 m

m

5

7

,0

 m

m

9

0

,0

 m

m

36,0 mm

7

8

9

10

11

12

1

2

3

4

5

6

C

O

N

T

R

O

L

Powersupply

www.boutronic.nl

GND

+24VDC IN

Type nummer JGA2011

+24VDC OUT

4-20mA in 2

GND

Inputs 4-20mA

RoHS compliant

TA : 0 ... 70  C

Relay 1

Relay 2

4-20mA in 1

Relay contacts

: 24VAC/DC max 1000mA

: 24VDC 50mA

: R-load = 500 Ohm

7

8

9

10

11

12

1

2

3

4

5

6

RoHS compliant

Type JGA2011

G

N

D

4

-2

0

m

A

 I

N

2

Relay 2

G

N

D

4

-2

0

m

A

 I

N

1

Relay 1

+

2

4

VD

C

 I

N

+

2

4

VD

C

 O

U

T

www.boutronic.nl

Made in the Netherlands

Lift front here for access control

 

Summary of Contents for JGA2011

Page 1: ...y JGA2011 is checked before sending for correct operation Therefore Boutronic has a warranty period of 1 year The warranty expires if The defect is caused by gross negligence or by improper installati...

Page 2: ...ns 3 Connection example 4 Operation 4 Current inputs 4 Potentiometer 5 Relay 5 Switching delay Relay 5 Change settings 6 Potentiometer 6 DIP switches 6 Setting with the serial menu 6 Relay 1 7 Relay 2...

Page 3: ...Relay1 24VD C IN 24VD C OU T www boutronic nl Made in the Netherlands Li ft front here for ac ces s control P2 Nr Unit Description 1 Connection 7 12 Connection 7 12 see front for type of connections 3...

Page 4: ...GND Level 0 100 4mA 0 20mA 100 DIP 3 OFF DIP 3 ON Software level 0 100 Delay on 1 sec Delay off 1 sec Hystereis 1 Delay on 1 600 sec Delay off 1 600 sec Hystersis 1 10 Relais 2 4 20 mA Current in 2 4...

Page 5: ...d is maximum Relay The relay switches when the corresponding input exceeds the switching threshold Input 1 switches relay 1 and input 2 switches relay 2 Switching delay Relay The switching delay with...

Page 6: ...Use software settings for threshold level Delay and hysteresis 4 Reserved Reserved Setting with the serial menu You can change the settings with the USB port and the Boutronic Studio The Boutronic St...

Page 7: ...1 sec Relay 2 Menu for changing setting relay 2 Value Description range Factory settings Level x Switching level when the relay is switching 0 100 50 Hysteresis x Hysteresis in 1 10 1 Delay on x sec...

Page 8: ...otecting range IP20 Power Description Min Typ Max Unit Remarks Power in 20 24 30 VDC 20 24 24 VAC 1 35 mA Power out 20 30 VDC 2 150 mA 3 1 Note one of the phases is directly connected to the GND 2 Thi...

Page 9: ...1 12 1 2 3 4 5 6 CONTROL Powersupply www boutronic nl GND 24VDC IN Type nummer JGA2011 24VDC OUT 4 20mA in 2 GND Inputs 4 20mA RoHS compliant TA 0 70 C Relay 1 Relay 2 4 20mA in 1 Relay contacts 24VAC...