23 June 2015
Version 1.7
Page 8-9
8.4.
Adjusting feed settings
Steps
To adust the feed settings, follow the steps in
STEP ACTION
1.
Open the
SETTINGS
tab of the
SERVICE
window.
2.
Press the
FEED
button.
The
FEED
) will be displayed.
Figure 8-5 Feed settings
3.
Select the desired milk box (1).
4.
Refer to
FEED
settings.
Scheme 8-4 Adjusting feed settings
Table 8-4 Feed settings
COMPONENT
DESCRIPTION
Eat speed (gr/s)
Specifies the default eating speed of the cow in
grams per second.
Attract feed
Drops a little feed in the trough of the milking
box if the box has not been visited for a long
time.
0 = Does
NOT
drop attract feed
1 = Drops attract feed
1