6
7
RISK OF FALLING
WHAT CAN HAPPEN
HOW TO PREVENT IT
• A portable compressor can fall from a
table, workbench, or roof causing damage
to the compressor and could result in
serious injury or death to the operator.
• Always operate compressor in a stable
secure position to prevent accidental
movement of the unit. Never operate
compressor on a roof or other elevated
position. Use additional air hose
to reach high locations.
RISK OF INJURY FROM LIFTING
WHAT CAN HAPPEN
HOW TO PREVENT IT
• Serious injury can result from attempting
to lift too heavy an object.
• The compressor is too heavy to be lifted
by one person. Obtain assistance from
others before lifting.
RISK FROM NOISE
WHAT CAN HAPPEN
HOW TO PREVENT IT
• Under some conditions and duration of
use, noise from this product may
contribute to hearing loss.
• Always wear proper hearing protection
during use.
SPECIFICATIONS
MODEL
CAP1645-OF
WEIGHT
83 lbs. (37.65 kg)
HEIGHT
15.5" (393.7 mm)
WIDTH
23" (584.2 mm)
Length
33" (838.2 mm)
Air Tank Capacity
4.5 Gallon (56.8 liters)
Approx. cut-in pressure
160 psi
Approx. cut-out pressure
200 psi
SCFM @ 90 PSI/ pI3
5.0 *
Noise Level
78 dBA +
Voltage
Single 120V
Minimum branch circuit requirement
15 A
Fuse Type
Time delay
Regulated Pressure Rating (Approximate)
3–150 psi
Quick Connect Type
1/4" (6.4 mm) Industrial
*Tested per ISO 1217:1996
+Tested per ISO 3744:1994