www.bosspac.com
7
Appendix A
Troubleshooting LED Flash Codes
The following table contains a brief description of all flash codes reported by the device:
FLASH CODE
DESCRIPTION
ACTION
1 Flash:
Accelerometer Failure
Device cannot communicate with the
accelerometer
Not user serviceable.
Replace sensor.
2 Flashes:
Battery Failure
Device battery is either too low or too
high.
Replace Battery as per the
Battery Installation section
of this manual.
3 Flashes:
Temperature Sensor Failure
Temperature Sensor readings are
outside of the start-up temperature
window, from -40°C to 100°C
Ensure that the mounting
point temperature is within
the allowable temperature
range and replace the
battery as per the Battery
Installation section of this
manual. If error persists
the sensor may need to be
replaced.
4 Flashes:
Radio Failure
Device could not initialize the radio.
Not user serviceably.
Replace sensor.
5 Flashes:
Regulator Failure
The onboard regulator is not able to
maintain the required voltage for
correct operation.
Replace Battery as per the
Battery Installation section
of this manual, if error
persists the sensor may be
faulty and need
replacement.
Support
For support contact BossPac Engineering & Technology toll free at
866-616-1226
.
Summary of Contents for WASP
Page 5: ...www bosspac com 5 ...