Control Status Indication:

Heating indicator  

  is displayed when the heat channel is switched ON.

Low Battery

•  When battery voltage below 2.4V, the low battery indicator 

 will be displayed 

on LCD. 

• When low battery occurs, the backlight will not illuminate.

Battery Cut-off Handling

• When the batteries reach cut-off voltage 2.1V, the LCD will turn off. 
•  After battery cut-off occurs, the thermostat will enter a cut-off state until new batteries have 

been fitted.

BOSS™ is a registered trademark of the Travis Perkins Group
Registered Office: Travis Perkins plc, Lodge Way House, Lodge Way, Harlestone Road, 
Northampton. NN5 7UG

Summary of Contents for TPST501

Page 1: ...ion where it may be subjected to direct sunlight The electrical connections to the TPST501 are made to the standard backplate supplied This simplifies installation as no connections are made to the controller itself Connection details are shown below no Earth connection is required for the correct and safe operation of the TPST501 but a parking terminal is provided to connect an Earth wire if one ...

Page 2: ...ST501 onto the backplate without the mains supply to the system being isolated Jumper Settings Changes to the jumper settings should only be made by the Engineer carrying out the installation or other qualified person Jumpers Description Span 3x1 pins jumper for 0 5 C or 1 0 C factory default setting selection It is used to define the system to run at 0 5 C or 1 0 C difference to the set temperatu...

Page 3: ...nnel is turned on for heating 6 Low batt indicator Indicates battery replacement is required 7 Auto Comf Econ Off mode indicator Indicates current mode Auto Comfort Economy Off 8 Set icon Indicates unit in setting mode 9 Program icon Indicates unit in programming mode Both SET and PROG are sown at the same time as SET PROG 10 Snowflake icon Indicates when unit is in OFF mode Initial Power Up After...

Page 4: ...C 2 Time 08 00 Time 10 00 Temp 18 C Temp 21 C 3 Time 12 00 Time 12 00 Temp 21 C Temp 21 C 4 Time 14 00 Time 14 00 Temp 18 C Temp 21 C 5 Time 18 00 Time 18 00 Temp 21 C Temp 21 C 6 Time 22 30 Time 23 00 Temp 16 C Temp 16 C Day Time Setting To set the day press D repeatedly to step through Press and hold the key 2 seconds the Day of the Week will change continuously To set the hour press H repeatedl...

Page 5: ...OMF Mode this setting will be remembered Anytime during the COMF mode press it will go back to the AUTO automatic mode Symbol on the LCD will be off icon will be displayed 2 ECON mode Press anytime to change into ECON mode will be displayed on the LCD Change the setting default 16 C the same as in COMF mode Anytime during the ECON mode press to return to AUTO automatic mode 3 AUTO mode Automatic m...

Page 6: ...am 2 and the Hour will flash for 10 seconds to allow you to set repeat steps 3 to 5 above 7 After Program 6 is set the next Day will flash as in step 1 8 Repeat step 1 to 6 to set the rest days Note During steps 1 8 above only or Select and Set have functionality During steps 1 8 above if there is no key press within 10 seconds the unit will store the current setting and return to AUTO mode Chrono...

Page 7: ...ample New Program 1 Time 06 30am Setpoint Temp 21 C 2 Time 7 00am Setpoint Temp 18 C 3 Time 7 00am Setpoint Temp 23 C 4 Time 7 00am Setpoint Temp 21 C 5 Time 7 00am Setpoint Temp 19 C 6 Time 10 30pm Setpoint Temp 16 C Installer Setting Mode There is one setting for installer Offset from 3 0 C to 3 0 C 1 Press and hold ON OFF over 2 seconds the unit is in Offset selection LCD will display OFS and s...

Page 8: ...tery occurs the backlight will not illuminate Battery Cut off Handling When the batteries reach cut off voltage 2 1V the LCD will turn off After battery cut off occurs the thermostat will enter a cut off state until new batteries have been fitted BOSS is a registered trademark of the Travis Perkins Group Registered Office Travis Perkins plc Lodge Way House Lodge Way Harlestone Road Northampton NN5...

Reviews: