background image

ENTERO

 

ESC

 ‐ 

INSTALLATION

 

MENU

 

GUIDE

 

 

22

 

To

 

SILENCE

 

an

 

emergency:

 

When

 

a

 

pre

recorded

 

message

 

is

 

active,

 

press

 

the

 

‘Pause

 

Alarm’

 

button

 

to

 

silence

 

(=mute)

 

the

 

currently

 

played

 

message(s);

 

the

 

‘Alarm’

 

status

 

stays

 

activated!

 

Press

 

the

 

‘Pause

 

Alarm’

 

button

 

again

 

to

 

re

activate

 

(=unmute)

 

the

 

emergency

 

message(s).

 

 

Additional

 

messages:

 

If

 

pre

configured

 

this

 

way;

 

the

 

A,

 

B,

 

C

 

and

 

D

 

buttons

 

allow

 

the

 

selection

 

of

 

different

 

messages,

 

instead

 

of

 

Alarm

 

zone

 

selection.

 

To

 

select

 

and

 

activate

 

one

 

of

 

these

 

messages,

 

perform

 

the

 

following

 

steps:

 

1.

 

Enable

 

panel

 

2.

 

Select

 

Alarm

 

zones

 

3.

 

Select

 

the

 

required

 

A,

 

B,

 

C,

 

or

 

D

 

(message)

 

button

 

4.

 

Press

 

the

 

‘Start/reset

 

Alarm’

 

button

 

 

Press

 

the

 

‘Start/reset

 

Alarm’

 

button

 

again

 

to

 

stop

 

the

 

message.

 

 

To

 

take

 

over

 

with

 

the

 

default

 

‘Emergency

 

message(s)’,

 

one

 

can

 

press

 

the

 

A,

 

B,

 

C

 

or

 

D

 

button

 

again

 

(without

 

pressing

 

the

 

‘Start/reset

 

Alarm’

 

button)

 

to

 

start

 

the

 

main

 

emergency

 

message(s),

 

played

 

in

 

the

 

same

 

zones.

 

 

Emergency

 

takeover

 

using

 

a

 

microphone

 

from

 

another

 

Emergency

 

panel:

 

A

 

takeover

 

is

 

only

 

possible

 

with

 

an

 

emergency

 

panel

 

having

 

a

 

higher

 

priority.

 

Follow

 

the

 

next

 

steps

 

to

 

takeover

 

an

 

active

 

emergency:

 

1.

 

Enable

 

panel

 

2.

 

Press

 

the

 

‘Start/reset

 

Alarm’

 

button;

 

the

 

activated

 

message

 

from

 

the

 

other

 

emergency

 

panel

 

will

 

stop

 

(>

 

the

 

Alarm

 

Zone

 

selection

 

will

 

be

 

remembered

 

in

 

the

 

background

 

&

 

the

 

‘ALARM’

 

indicator

 

will

 

stay

 

ON),

 

3.

 

Press

 

‘Pause

 

Alarm’

 

to

 

temporary

 

silence

 

this

 

panel;

 

this

 

allows

 

the

 

user

 

to

 

select

 

new

 

Alarm

 

zones;

 

if

 

‘Pause

 

Alarm’

 

is

 

not

 

selected

 

at

 

this

 

stage

 

and

 

one

 

presses

 

an

 

alarm

 

zone

 

button

 

directly,

 

the

 

alarm

 

message

 

will

 

immediately

 

play

 

in

 

that

 

(group

 

of)

 

alarm

 

zone(s)

 

(so

 

step

 

4

 

is

 

performed

 

without

 

the

 

‘Pause

 

Alarm’

 

function),

 

4.

 

Select

 

Alarm

 

zones

 

(see

 

above),

 

5.

 

Select

 

microphone

 

or

 

pre

recorded

 

messages

 

by;

 

a.

 

press

 

and

 

hold

 

the

 

‘Microphone’

 

button

 

(see

 

above)

 

or,

 

b.

 

by

 

pressing

 

the

 

‘Pause

 

Alarm’

 

button

 

the

 

silence

 

is

 

set

 

back

 

(the

 

‘Start/reset

 

Alarm’

 

button

 

was

 

already

 

activated

 

in

 

this

 

situation)

 

and

 

pre

recorded

 

messages

 

will

 

be

 

played

 

 

To

 

stop

 

the

 

takeover

 

from

 

a:

 

 

Microphone

 

announcement;

 

1.

 

release

 

the

 

microphone

 

button,

 

2.

 

de

select

 

all

 

zone

 

buttons,

 

3.

 

press

 

the

 

‘Pause

 

Alarm’

 

button

 

(removes

 

‘silence’),

 

4.

 

press

 

the

 

‘Start/reset

 

Alarm’

 

button

 

(which

 

performs

 

a

 

‘reset’)

 

and

 

the

 

initial

 

Emergency

 

panel

 

will

 

be

 

re

activated

 

automatically

 

 

Pre

recorded

 

message(s);

  

1.

 

press

 

the

 

‘Pause

 

Alarm’

 

button

 

to

 

silence

 

the

 

running

 

message(s),

 

2.

 

de

select

 

all

 

zone

 

buttons,

  

3.

 

press

 

the

 

‘Pause

 

Alarm’

 

button

 

again

 

(removes

 

‘silence’),

 

4.

 

press

 

the

 

‘Start/reset

 

Alarm’

 

button

 

(which

 

performs

 

a

 

‘reset’)

 

and

 

the

 

initial

 

Emergency

 

panel

 

will

 

be

 

re

activated

 

automatically.

 

   

Summary of Contents for Entero ESC

Page 1: ...Rev 1 0 Entero Voice Alarm system Entero ESC installation menu guide ...

Page 2: ...ENTERO ESC INSTALLATION MENU GUIDE 2 The manufacturer reserves specification privileges Information in this manual is subject to change without prior notice or obligation ...

Page 3: ...ntero Evacuation panel and Fire panel 5 1 3 Entero ESA Power Amplifier 6 1 4 Entero EPC Emergency Power Controller 6 2 Indicators and controls access level 2 7 2 1 Entero ESC Emergency System Controller 7 2 2 Main screen 8 2 3 System menu 8 3 System configuration access level 3 11 4 Entero Fire Panel and Evacuation Panel 20 Appendix Error messages 23 ...

Page 4: ...ACIE in accordance with the manufacturer s published instructions and data Access level 4 For persons who are trained and authorized by the manufacturer to either repair the VACIE or alter its firmware thereby changing its basic mode of operation Accessibility of indications and controls at Access level 1 All mandatory indications Voice Alarm condition General errors System faults and Power status...

Page 5: ...hone announcement is active in the Voice Alarm system 1 2 Entero Evacuation panel and Fire panel 1 230Vac GREEN indicates the 230 Vac power status when OFF the power source is disconnected or the unit is not yet calibrated 48 Vdc indicator also OFF 2 48Vdc GREEN indicates the 48 Vdc power status when OFF the power source is disconnected or the unit is not yet calibrated 230 Vac indicator also OFF ...

Page 6: ...ay not be operating anymore 1 4 Entero EPC Emergency Power Controller 1 230Vac INPUT GREEN YELLOW when this indicator is GREEN it shows a correct operating 230 Vac mains power input when the indicator is changed to YELLOW there is an error on the 230 Vac input 2 48Vdc INPUT GREEN YELLOW when this indicator is GREEN it shows a correct operating 48 Vdc battery power input when the indicator is chang...

Page 7: ...s and the number of outputs in test mode Different menu items are available in the System menu ENTERO M1 UNIT OK AC Power 230V OK DC Power 48V OK 48 3V Communication OK Confirmed errors 0 0 Outputs in test mode 0 12 SYSTEM MENU 2 Indicators show the status of POWER SYSTEM FAULTS GENERAL ERRORS and ALARM See also Indicators access level 1 above for more details 3 Navigation buttons use the navigati...

Page 8: ...r indicator test Reset error RETURN System overview System overview shows a list of all components like amplifiers loudspeakers lines error contacts emergency panels and other which have been found during the calibration routine of the system SYSTEM OVERVIEW Speakerline1 No Amp found Speakerline2 A 98W B 30W Speakerline3 A 250W B 125W Speakerline4 A B Opn L Speakerline5 A Opn L B 35W Speakerline6 ...

Page 9: ... and press OK to acknowledge the error To leave this window without acknowledging the error press OK to return when NO is displayed Installation menu See chapter System configuration access level 3 for more details Ext Sig Audio not installed EPC error in installed Ext error in installed Mains error in installed Power 48Vdc installed Wallcontr 1 not installed Wallcontr 2 not installed Wallcontr 3 ...

Page 10: ...ed off RESET ERROR M1 L5 A open Line error M1 Evacpanel4 MicLine2 reset M1 Slave1 com reset M1 L12 B open Line error M1 Firepanel1 MicLine1 reset RETURN Use the up down buttons to select the error and press OK the following menu will appear RESET ERROR M1 L5 Aopen Line error Reset this error NO Use to change press OK To reset the error use the up button to change from NO to YES and press OK To lea...

Page 11: ...displayed Installation menu 1 System overview 2 Test mode overview 3 Unit setup 4 Emergency panel setup M1 5 Battery 6 Rack master slave settings 7 Calibrate whole unit 8 Error log 9 Clear error log 10 Language selection 11 Factory restore 12 Change password RETURN 1 System overview System overview shows a list of all components like amplifiers loudspeakers lines error contacts emergency panels an...

Page 12: ...ut 10 Input Input 11 Input Input 12 Input Return Use the up and down buttons to select an input and press OK the following will be displayed Input 1 Input Input sensitivity 0dB Input gain 0dB RETURN Input sensitivity To change the input sensitivity press OK the 0 dB value will now highlight Use the up and down buttons to change to 10 dB 0 dB or 3dB Press OK again to store the new value Input Gain ...

Page 13: ... RETURN Output Gain To adjust the output gain 80 to 6 dB use the up and down buttons to select the settings and press OK to select value use up and down to change value and press OK to store Emergency Gain To adjust the level of the emergency signal 80 to 6 dB routed to this output only use the up and down buttons to select this menu item and press OK to select value use up and down to change valu...

Page 14: ... Deviation 1k 50W Clear calibration Press OK Calibrate output Press OK RETURN Speaker line in test mode To temporary turn off speaker line monitoring press the OK button to switch from NO to YES to put the output into test mode no errors will be reported In case a short circuit occurs on the line the line will still be disconnected If the amplifier fails which powers this line it will switch to a ...

Page 15: ...wn button to go to the next menu line Clear calibration Press OK to clear a calibrated speaker line Use the up and down button to change NO to YES and press OK to clear and return to the previous menu position Clear this speaker line NO Use up down to change press OK Use the down button to go to the next menu line Calibrate output Press OK to calibrate speaker lines connected to this output Use th...

Page 16: ... line connected 100V or low impedance In case an output needs to be cleared at the same time select CLR For all other items select YES or NO 3 3 Calibrate Unit Select all NO Output 1 100V Output 2 CLR Output 3 L Imp Output 4 YES Output 5 NO Output 6 NO Output 7 NO Output 8 NO Output 9 NO Output 10 NO Output 11 NO Output 12 NO Emergency panels NO ExtContacts 48Volt DC NO Slaves NO Calibrate selecte...

Page 17: ...gency panel bus 2 4dB Ext signal input 3dB RETURN Use the up and down buttons to select Alarm message 1 or 2 or one of the emergency inputs and press OK to select the current gain value use the up and down buttons to change this value and press OK to store 5 Battery The battery menu displays the actual voltage of the secondary power source connected to the Entero ESC 5 Battery Battery voltage 48 5...

Page 18: ...el4 MicLine2 reset M1 Slave1 com reset M1 L12 B open Line error M1 Firepanel1 MicLine1 reset RETURN Use the up and down buttons to select an active error and press OK 8 Error log M1 L5 A open Line error Reset this error NO Use up down to change press OK To reset the error use the up and down button to switch between NO and YES if YES is selected press OK to reset 9 Clear error log Enter this menu ...

Page 19: ... restore the unit to factory default settings 11 Factory restore Factory restore this unit NO Use up down to change press OK Use the up and down button to switch between NO and YES if YES is selected press OK to perform a factory restore 12 Change password Enter this menu to change the password to enter the installation menu Installation menu Enter new password 0000 Use up down to change press OK ...

Page 20: ...iority 1 Fire Panel microphone 2 Evacuation Panel microphone 3 Fire Detection System interface mic line input 4 Fire Panel alarm message s 5 Evacuation Panel alarm message s 6 Fire Detection System interface 7 External Audio input NOTE the Fire Detection System interface and the External Audio input have no manual controls and are therefore not covered in this manual Fire Evacuation Panel main con...

Page 21: ...and D buttons when the code is right the Panel Disabled indicator will turn OFF 2 Alarm zone selection alarm zones can be selected in different ways a Press the ALL ZONES button to select all alarm zones or b Press the A B C or D button if these are pre configured with a group of alarm zones or c Press 1 or more zones on the 12 button expansion card NOTE the corresponding indicator will illuminate...

Page 22: ...vated message from the other emergency panel will stop the Alarm Zone selection will be remembered in the background the ALARM indicator will stay ON 3 Press Pause Alarm to temporary silence this panel this allows the user to select new Alarm zones if Pause Alarm is not selected at this stage and one presses an alarm zone button directly the alarm message will immediately play in that group of ala...

Page 23: ... B Short Circuit error a short circuit is found on the line the line will be disconnected automatically Lxx A Open Line error the loudspeaker line is disconnected Lxx B Open Line error the loudspeaker line is disconnected Lxx Short to Earth Line A B a short circuit to Earth is found the line will be disconnected automatically Lxx A 1 KHz Impedance error an impedance deviation is found on the line ...

Page 24: ...above error contacts is also monitored the following error messages indicate a failure of this connection not the status of the error input itself Connection failures to Possible error description Mains error input Mains Con short error line to error contact is shorted Mains Con open error line to contact is open External error input Ext Con short error line to ext error contact is shorted Ext Con...

Reviews: