24
Commissioning
Sense II – 6 720 818 367 (2015/10)
5.4
Commissioning other settings
If some functions are not activated, and modules, units or
components are not installed, the irrelevant items are hidden,
while other settings are selected.
5.4.1 Checklist: Adjusting settings to customer
requirements
When commissioning the device, ensure the satisfaction of the
customer is met, making sure that the heating system meets
the customer's needs and will not give cause for complaints. In
our experience, the following settings are very important for
the satisfaction of the system user:
▶ Adjust settings to customer requirements in the main menu
(
operating instructions).
5.4.2 Important settings for the heating system
In any case, the settings in the heating menu must be checked
and, if necessary, adjusted during commissioning. This is
important to ensure the optimum functioning of the heating
system. It is useful to check all displayed settings.
▶ Check settings in the system data menu (
▶ Check settings in the boiler data menu (
▶ Check settings in the heating circuit 1 – 4
(
5.4.3 Important settings for the DHW system
The settings in the DHW menu must be checked and, if
necessary, adjusted during commissioning. This is important to
ensure the proper functioning of the DHW heating.
▶ Check the settings in the DHW system I, II menu
(
5.4.4 Important settings for the solar system
These settings are only available if the solar system is designed
and configured accordingly. For further details see technical
documentation for MS 100/MS 200 modules.
▶ Check the settings in the Solar menu (
page 44 and installation instructions MS 100 or MS 200)
5.4.5 Important settings for the hybrid system
Observe technical documentation of the hybrid system and
Chapter 7.4, page 45 to ensure proper functioning.
5.4.6 Important settings for cascades
Observe technical documentation (e.g. MC 400) and
Chapter 7.5, page 45 to ensure proper functioning.
5.5
Perform function tests
The function tests can be accessed via the diagnosis menu. The
available menu items are strongly dependant on the installed
system. Under this menu the system components can be
tested, for example:
Burner
:
On
/
Off
(
5.6
Check monitored values
Monitored values are shown in the
Diagnosis
menu
(
5.7
System handover
▶ Ensure that no temperature limits for heating and DHW
have been set at the heat source and that DHW preheat is
enabled on the boiler. Only under this condition can the
Sense II controller control the DHW and flow temperatures.
▶ Enter the contact details of the responsible contractor in
the
Diagnosis
>
Maintenance
>
Contact address
menu,
e.g. company name, phone number and address or e-mail
address (
▶ Explain to the customer how the controller and the
accessories work and how to operate them.
▶ Inform customer about the selected settings.
Menu item
Customer requirement/setting
Fast heat-up
Setting value in percentage or
switch off (
Start frequency DHW
circ. (DHW circulation
pump)
Permanently, 1 x 3 ..., 6 x
3 minutes/h (
DHW priority
Yes | No (
Time program
Adjust default settings/own time
program according to customer
requirements (
operating
instructions of the controller).
Table 15 Checklist: Important settings, clarifying customer
requirements
We recommend to hand over these installation
instructions to the customer after
commissioning the heating system.