CONDENSATE CONNECTION:
Never terminate or discharge into any open
source, including; sink, bath, shower, bidet,
toilet etc
.
Note: any external condensate pipework
should be protected with weather resistant
insulation to help prevent freezing.
• Ensure that the condensate drain is 22mm
diameter plastic pipe. It must fall at least
50mm per metre towards the outlet.
• An adapter in 22mm pipe is contained in the
fitting pack (A) along with sealing washer (B).
CONDENSATE CONNECTION
A
B
CONDENSATE CONNECTION
INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER BOSCH GREENSTAR 12i System/24i System
8 716 107 375a (02/05)
26
IN
ST
AL
LA
TI
O
N
IMPORTANT: IF FITTING OPTIONAL
INTEGRAL DIVERTER VALVE
Now fit the diverter valve.
For installa-
tion refer to FITTI NG TH E DIVE RTE R
VALVE in the ADDITIONAL INFORMATION
section at the back of the book. You must
then disregard the following 3 pages con-
cerning ELECTRICAL and PRE-COMMIS-
SIONING CHECKS and refer to the cor-
rect versions that follow FITTING THE
DIVE RTE R VALVE in the ADDITIONAL
INFORMATION section at the back of this
book.