en
Faults and what to do about them
46
r
■
Flashes
(no water supply): Water tap turned on? Filter in the water supply is
blocked?
"Filter in the water supply is blocked" on page 44
Is the supply hose kinked or trapped?
■
Lights up
(low water pressure): For information only. This will not affect the
programme progress. The programme duration is extended.
E
lights up
The childproof lock is activated – deactivate it.
The symbol
Û
flashes
Run the
i
Algodón/Algodão 90°C (Cottons 90°C)
programme to clean and
care for the drum and the outer tub.
Notes
■
Run the programme without laundry.
■
Use washing powder or a detergent containing bleach. To prevent foaming,
only use half the amount of detergent recommended by the detergent manu-
facturer. Do not use detergent designed for woollens or delicates.
■
Switching the drum care information signal on/off.
E:36
alternating with
-10
■
Drain pipe or water drain hose is blocked. Clean the drain pipe and the water
outlet hose.
■
Drain pipe or water drain hose is caught or jammed. Ensure that the drain pipe
and water drain hose are not kinked or trapped.
■
The drain pump is blocked.
"Drain pump is blocked" on page 42
■
The drain hose at the siphon is blocked.
"The drain hose at the siphon is blocked" on page 44
■
The water drain hose is connected too high. Install the water outlet hose at a
maximum height of 1 meter.
E:35
alternating with
-10
(Suitable for spe-
cial models)
There is water in the base trough, the appliance is leaking. Turn off the tap. Call
customer services.
H:95
alternating with
“Ÿš
when programme is
finished
No water detected in drying phase, may get bad drying result.
"Filter in the water supply is blocked" on page 44
H:32
alternating with
“Ÿš
when programme is
finished
The unbalanced load detection system has interrupted the spin cycle because the
laundry is unevenly distributed. Distribute small and large items of laundry evenly in
the drum.
Other displays
Turn the programme selector to
Û
(Off)
, wait for five seconds and then switch it on
again. If the display appears again, call customer services.
Display
Cause/Remedy