en
Positioning and connecting
16
Connection on right side
Note:
If the supply hose is too short for
your connection, you can order an
extension from the after-sales service.
Water inlet
:
Warning
Risk of death!
There is a risk of electric shock if you
touch live components.
Do not immerse the Aqua-Stop safety
valve* in water (it contains an electric
valve).
* Depending on the model
Observe the following when connecting
the appliance:
Notes
■
Only operate the appliance using
cold mains water.
■
Do not connect the appliance to the
mixer tap of an unpressurised hot-
water boiler.
■
Do not use a used supply hose. Only
use the supply hose supplied or one
that was purchased from an
authorised specialist retailer.
■
Do not bend, squash, modify or cut
through the water supply hose
(otherwise its strength is no longer
guaranteed).
■
Only tighten the screw connections
by hand. If the screw connections
are tightened too much with a tool
(pliers), the thread may be
damaged.
Optimum water pressure in the supply
network
At least
100 kPa (1 bar)
Maximum
1000 kPa (10 bar)
When the tap is open, the water flow is
at least 8 l/min.
If the water pressure is higher than this,
a pressure-reducing valve must be
installed.
Connection
1.
Connect the water supply hose to
the water tap (¾" = 26.4 mm) and to
the appliance:
– Model:
Standard
– Model:
Aqua
Secure
(
~ 95 cm
0
~ 140 cm
8
~ 145 cm
@
0 cm ~ 100 cm
#
Summary of Contents for WGA244U0AU