Operation

 | 

5

8 716 473 217 (2014/07)

Gaz 6000 W

4.2

Switching the appliance on/off

Switching on

▶ Start the appliance at the standby key.

The display shows the heating water flow temperature.

Switching off/standby mode

▶ Shut down the appliance at the standby key.

Only the warning symbol continues to be displayed. 

Fig. 7  

▶ If the appliance is to be switched off for a longer period of time: 

observe correct frost protection procedures (

 chapter 4.6).

Power interruption

▶ Press and hold on OK button to reset the appliance when a fault code 

(eg.EA) flashes because of power interruption.   

4.3

Setting the maximum flow temperature

The maximum flow temperature can be set between 40 °C and 
approx. 82 °C. The current flow temperature is shown on the display. 

▶ Keep pressing   –  until the 

 symbol appears on the display.

▶ Press OK.

The set maximum flow temperature is displayed. 

▶ Press + and   –  to set the required maximum flow temperature.
▶ Press OK to save the setting.

The display shows the current flow temperature.

You can find typical maximum flow temperatures in tab. 2.

When the burner is active in heating mode, the 

 symbol and the 

 burner symbol appear on the display.

4.4

Setting the heating control unit

4.5

Setting summer mode

The heating circuit pump and consequently central heating are switched 
off. Power supply for the heating control unit and timer are retained.

To set summer mode:
▶ Keep pressing   –  until the 

 symbol appears on the display.

▶ Press OK.

The set maximum flow temperature is displayed. 

▶ Keep pressing   –  until

 .  .

 appears on the display. 

▶ Press OK to save the setting.

 is permanently displayed.

Additional instructions are contained in the operating instructions for 
the heating programmer.

4.6

Setting frost protection

Frost protection for the heating system:

Frost protection for the heating system is only ensured if the heating 
circuit pump is operational and is pumping heating water through the 
entire system.

▶ Leave the heating switched on.
▶ Set the maximum flow temperature to at least 40 °C (

 Chapter 4.3).

-or-

 If you want to leave the appliance switched off:

▶ Ask your heating contractor to mix anti-freeze (see installation 

instructions) into the heating water.

Appliance frost protection:

The appliance frost protection function switches the burner and heating 
circuit pump on when the temperature falls below 5 °C. This prevents the 
boiler freezing up.

▶ Activate summer mode (

 Chapter 4.5) or put the appliance in 

standby mode (

 Chapter 4.2).

The appliance has an anti-seizing function which 
prevents the heating circuit pump and the 3-way valve 
seizing up following long periods of inactivity.
The anti-seizing function remains active during standby 
mode.

When 

 is set, heating mode is disabled 

(summer mode).

Flow temperature

Sample application

 symbol appears

Summer mode 

Approx. 75 °C

Radiator heating system

approx. 82 °C

Convector heating system

Table 2  Maximum flow temperature

ok

6

 

720

 

806

 

464-06.1O

 

Observe the operating instructions of the heating 
controller. This shows you:
▶ how to adjust the room temperature,
▶ how to heat economically and save energy. 

NOTICE: 

Heating system at risk through frost. In summer 

mode, only the appliance is protected against frost.
▶ Observe frost protection measures where there is a 

risk of frost (

 Chapter 4.6).

For further information, see the heating controller 
operating instructions.

NOTICE: 

Heating system at risk through frost. In 

summer/standby mode, only the appliance is protected 
against frost.

Summary of Contents for WBN 6000-30-H-E-N/L-S2400

Page 1: ...Operating instructions for the end customer Gas boiler Gaz 6000 W 8 716 473 216 00 3O WBN 6000 30 H E N L S2400 8 716 473 217 2014 07 en ...

Page 2: ...t Do not use the telephone or ring doorbells Turn off the gas at the meter Open windows and doors Warn your neighbours and leave the building Prevent anyone from entering the building Well away from the building call the fire brigade police and gas supplier Intended use This boiler must only be used as a heat appliance in a sealed hot water heating system for domestic purposes Anyotheruseisconside...

Page 3: ...ndows and walls Combustion air room air Theairintheinstallationroommustbefreeofcombustibleorchemically aggressive substances Do not use or store combustible or explosive materials paper propellants thinners paints etc withinthevicinityoftheappliance Do not use or store corrosive substances solvents adhesives chlorinated cleaning agents etc within the vicinity of the appliance 2 Product details WBN...

Page 4: ... Close the fill valve 4 Operation 4 1 Overview of controls Fig 6 1 Standby key 2 Burner operation 3 Fault display standby mode display 4 Heating mode active 5 DHW heating active N A 6 Summer mode active 7 Service Mode 8 Temperature display in C 9 key mode 10 Back key exit service function submenu without saving 11 key 12 OK button confirm selection save value NOTICE Damage to appliance due to cold...

Page 5: ...ons are contained in the operating instructions for the heating programmer 4 6 Setting frost protection Frost protection for the heating system Frost protection for the heating system is only ensured if the heating circuit pump is operational and is pumping heating water through the entire system Leave the heating switched on Setthemaximumflowtemperaturetoatleast40 C Chapter 4 3 or If you want to ...

Page 6: ...ever leave windows slightly open for ventilation purposes Otherwise heat will be constantly discharged from the room without significantly improving the room s air It is better to fully open windows briefly Close the thermostatic radiator valves while airing rooms Circulation pump If there is a circulation pump for hot water use a timer programme to control its operation according to the specific ...

Page 7: ...protection is a fundamental corporate strategy of the Bosch Group The quality of our products their efficiency and environmental safety are all of equal importance to us and all environmental protection legislation and regulations are strictly observed We use the best possible technology and materials for protecting the environment taking into account of economic considerations Packaging Wepartici...

Page 8: ......

Reviews: