background image

Product details

 | 

3

8 716 473 217 (2014/07)

Gaz 6000 W

We recommend you enter into a contract for the annual inspection and 
demand-dependent servicing with an authorised contractor.

▶ Have any work carried out only by an authorised contractor.
▶ If any faults are discovered, have them remedied immediately.

Modifications and repairs

Unprofessional modifications to the boiler or other parts of the heating 
system can result in injury and/or damage to property or equipment. 

▶ Have any work carried out only by an authorised contractor.
▶ Do not remove the boiler case.
▶ Do not modify the boiler or other parts of the heating system in any 

way.

Open flue operation

The installation room must be adequately ventilated if the appliance 
draws its combustion air from the room.

▶ Consult an authorised contractor to ensure the ventilation 

requirements are met:
– if structural modifications are made (e.g. replacing windows and 

doors)

– if appliances are subsequently installed which route extract air to 

the outside (e.g. extract air fans, kitchen fans or air conditioning 
units).

▶ Never cover or reduce the size of ventilation apertures in doors, 

windows and walls.

Combustion air/room air

The air in the installation room must be free of combustible or chemically 
aggressive substances.

▶ Do not use or store combustible or explosive materials (paper, 

propellants, thinners, paints, etc.) within the vicinity of the appliance.

▶ Do not use or store corrosive substances (solvents, adhesives, 

chlorinated cleaning agents, etc.) within the vicinity of the appliance.

2

Product details

WBN 6000-30-H-E-N/L-S2400 

are appliances for central heating.

2.1

Standard delivery

Fig. 1  

[1]

Wall-mounted gas boiler

[2]

Fixing material

[3]

Set of printed documents for the appliance

[4]

Flue pipe

[5]

Grommet

[6]

Regulator( Only for NG appliance ) 

3

Preparing the appliance for use

3.1

Overview of connections

Fig. 2  

[1]

Drain hose

[2]

Heating return valve (accessory)

[3]

Cold water valve (accessory)

[4]

Gas valve (closed) (accessory)

[5]

Heating flow valve (accessory)

3.2

Opening service valves

▶ Push in the handle and turn it fully anti-clockwise (the gas tap is open 

when the handle is in line with the flow).

Fig. 3  

3.3

Check the central heating system pressure

The standard operating pressure is 1 - 2 bar.

Should a higher operating pressure be required, refer to your heating 
contractor.

Fig. 4  

1

3

4

5

6

2

8 716 473 216-01.2O

2

3

4

5

1

8 716 473 217-01.1O

8 716 473 217-02.1O

ok

reset

press 5s

2.

1.

8 716 473 217-03.1O

ok

reset

press 5s

2

3

1

4

bar

0

Summary of Contents for WBN 6000-30-H-E-N/L-S2400

Page 1: ...Operating instructions for the end customer Gas boiler Gaz 6000 W 8 716 473 216 00 3O WBN 6000 30 H E N L S2400 8 716 473 217 2014 07 en ...

Page 2: ...t Do not use the telephone or ring doorbells Turn off the gas at the meter Open windows and doors Warn your neighbours and leave the building Prevent anyone from entering the building Well away from the building call the fire brigade police and gas supplier Intended use This boiler must only be used as a heat appliance in a sealed hot water heating system for domestic purposes Anyotheruseisconside...

Page 3: ...ndows and walls Combustion air room air Theairintheinstallationroommustbefreeofcombustibleorchemically aggressive substances Do not use or store combustible or explosive materials paper propellants thinners paints etc withinthevicinityoftheappliance Do not use or store corrosive substances solvents adhesives chlorinated cleaning agents etc within the vicinity of the appliance 2 Product details WBN...

Page 4: ... Close the fill valve 4 Operation 4 1 Overview of controls Fig 6 1 Standby key 2 Burner operation 3 Fault display standby mode display 4 Heating mode active 5 DHW heating active N A 6 Summer mode active 7 Service Mode 8 Temperature display in C 9 key mode 10 Back key exit service function submenu without saving 11 key 12 OK button confirm selection save value NOTICE Damage to appliance due to cold...

Page 5: ...ons are contained in the operating instructions for the heating programmer 4 6 Setting frost protection Frost protection for the heating system Frost protection for the heating system is only ensured if the heating circuit pump is operational and is pumping heating water through the entire system Leave the heating switched on Setthemaximumflowtemperaturetoatleast40 C Chapter 4 3 or If you want to ...

Page 6: ...ever leave windows slightly open for ventilation purposes Otherwise heat will be constantly discharged from the room without significantly improving the room s air It is better to fully open windows briefly Close the thermostatic radiator valves while airing rooms Circulation pump If there is a circulation pump for hot water use a timer programme to control its operation according to the specific ...

Page 7: ...protection is a fundamental corporate strategy of the Bosch Group The quality of our products their efficiency and environmental safety are all of equal importance to us and all environmental protection legislation and regulations are strictly observed We use the best possible technology and materials for protecting the environment taking into account of economic considerations Packaging Wepartici...

Page 8: ......

Reviews: