Product details
|
3
8 716 473 217 (2014/07)
Gaz 6000 W
We recommend you enter into a contract for the annual inspection and
demand-dependent servicing with an authorised contractor.
▶ Have any work carried out only by an authorised contractor.
▶ If any faults are discovered, have them remedied immediately.
Modifications and repairs
Unprofessional modifications to the boiler or other parts of the heating
system can result in injury and/or damage to property or equipment.
▶ Have any work carried out only by an authorised contractor.
▶ Do not remove the boiler case.
▶ Do not modify the boiler or other parts of the heating system in any
way.
Open flue operation
The installation room must be adequately ventilated if the appliance
draws its combustion air from the room.
▶ Consult an authorised contractor to ensure the ventilation
requirements are met:
– if structural modifications are made (e.g. replacing windows and
doors)
– if appliances are subsequently installed which route extract air to
the outside (e.g. extract air fans, kitchen fans or air conditioning
units).
▶ Never cover or reduce the size of ventilation apertures in doors,
windows and walls.
Combustion air/room air
The air in the installation room must be free of combustible or chemically
aggressive substances.
▶ Do not use or store combustible or explosive materials (paper,
propellants, thinners, paints, etc.) within the vicinity of the appliance.
▶ Do not use or store corrosive substances (solvents, adhesives,
chlorinated cleaning agents, etc.) within the vicinity of the appliance.
2
Product details
WBN 6000-30-H-E-N/L-S2400
are appliances for central heating.
2.1
Standard delivery
Fig. 1
[1]
Wall-mounted gas boiler
[2]
Fixing material
[3]
Set of printed documents for the appliance
[4]
Flue pipe
[5]
Grommet
[6]
Regulator( Only for NG appliance )
3
Preparing the appliance for use
3.1
Overview of connections
Fig. 2
[1]
Drain hose
[2]
Heating return valve (accessory)
[3]
Cold water valve (accessory)
[4]
Gas valve (closed) (accessory)
[5]
Heating flow valve (accessory)
3.2
Opening service valves
▶ Push in the handle and turn it fully anti-clockwise (the gas tap is open
when the handle is in line with the flow).
Fig. 3
3.3
Check the central heating system pressure
The standard operating pressure is 1 - 2 bar.
Should a higher operating pressure be required, refer to your heating
contractor.
Fig. 4
1
3
4
5
6
2
8 716 473 216-01.2O
2
3
4
5
1
8 716 473 217-01.1O
8 716 473 217-02.1O
ok
reset
press 5s
2.
1.
8 716 473 217-03.1O
ok
reset
press 5s
2
3
1
4
bar
0