Operating instructions for the end customer

Gas boiler

Gaz 6000 W

8 716 473 216-00.3O

WBN 6000-30-H-E-N/L-S2400

8 716 473 217 (2014/07) en

Summary of Contents for WBN 6000-30-H-E-N/L-S2400

Page 1: ...Operating instructions for the end customer Gas boiler Gaz 6000 W 8 716 473 216 00 3O WBN 6000 30 H E N L S2400 8 716 473 217 2014 07 en ...

Page 2: ...t Do not use the telephone or ring doorbells Turn off the gas at the meter Open windows and doors Warn your neighbours and leave the building Prevent anyone from entering the building Well away from the building call the fire brigade police and gas supplier Intended use This boiler must only be used as a heat appliance in a sealed hot water heating system for domestic purposes Anyotheruseisconside...

Page 3: ...ndows and walls Combustion air room air Theairintheinstallationroommustbefreeofcombustibleorchemically aggressive substances Do not use or store combustible or explosive materials paper propellants thinners paints etc withinthevicinityoftheappliance Do not use or store corrosive substances solvents adhesives chlorinated cleaning agents etc within the vicinity of the appliance 2 Product details WBN...

Page 4: ... Close the fill valve 4 Operation 4 1 Overview of controls Fig 6 1 Standby key 2 Burner operation 3 Fault display standby mode display 4 Heating mode active 5 DHW heating active N A 6 Summer mode active 7 Service Mode 8 Temperature display in C 9 key mode 10 Back key exit service function submenu without saving 11 key 12 OK button confirm selection save value NOTICE Damage to appliance due to cold...

Page 5: ...ons are contained in the operating instructions for the heating programmer 4 6 Setting frost protection Frost protection for the heating system Frost protection for the heating system is only ensured if the heating circuit pump is operational and is pumping heating water through the entire system Leave the heating switched on Setthemaximumflowtemperaturetoatleast40 C Chapter 4 3 or If you want to ...

Page 6: ...ever leave windows slightly open for ventilation purposes Otherwise heat will be constantly discharged from the room without significantly improving the room s air It is better to fully open windows briefly Close the thermostatic radiator valves while airing rooms Circulation pump If there is a circulation pump for hot water use a timer programme to control its operation according to the specific ...

Page 7: ...protection is a fundamental corporate strategy of the Bosch Group The quality of our products their efficiency and environmental safety are all of equal importance to us and all environmental protection legislation and regulations are strictly observed We use the best possible technology and materials for protecting the environment taking into account of economic considerations Packaging Wepartici...

Page 8: ......