4.3 Requirements for the in-
stallation location
WARNING
Risk of electric shock!
The appliance contains live parts.
Touching live parts is dangerous.
▶
Do not operate the appliance
without a cover cap.
WARNING
Risk of injury!
When using the appliance on a base,
the appliance may tip over.
▶
Always secure the feet of the appli-
ance to a base using the manufac-
turer's fixing brackets →
before using the appliance for the
first time.
ATTENTION!
If residual water in the appliance
freezes, this may cause damage to
the appliance.
▶
Do not install or operate this appli-
ance anywhere that is liable to ex-
perience frost or outdoors.
If the appliance is tilted at an angle
greater than 40°, residual water may
leak out of the appliance and cause
material damage.
▶
Tilt the appliance carefully.
▶
Transport the appliance in an up-
right position.
Installation loca-
tion
Requirements
Base
Secure the appli-
ance with fixing
brackets
→
Installation loca-
tion
Requirements
Wooden joist
floor
Place the appli-
ance on a water-
resistant wooden
board (minimum
thickness of
30 mm) which is
screwed tightly to
the floor.
Kitchen unit
Only install the
appliance under-
neath a continu-
ous worktop that
is securely con-
nected to adja-
cent cabinets.
Required niche
width: 60 cm.
Against a wall
Do not trap the
hoses between
the wall and the
appliance.
4.4 Removing the transit
bolts
The appliance is secured for trans-
portation using transit bolts on the
rear of the appliance.
Note:
Keep the transit bolt screws
and the sleeves in a safe place for fu-
ture transport →