Operation and maintenance

Sealed parts must not be interfered with.

3.1

Function

This water heater is fitted with piezo ignition that provides
for easy commissioning.
In first place it must dislocate the output control of the off
position to the ignition position (see fig. 5).
Press in the slide control knob and subsequently press the
piezo button. Release the slide control after about 15
seconds, if the pilot flame does not stay alight, repeat the
operation.
Ignition may not be successful due to the presence of air
inside the gas supply pipe, especially if first connected or
after long inactive periods. In this case, keep the output
control knob fully depressed until the gas pipe has been
totally purged.
Slide the gas control slide fully to the right to obtain maximum
output. Sliding the gas control slide to the left reduces the
output.
In order to optimise energy consumption, adjust the output
control to supply the minimum output required.
After following these procedures, ignition of the main burner
will automatically take place whenever you turn on a hot
water tap, since the pilot burner is permanently alight.
When you want to switch off the heater, move the  slide
control to the far left. After a few seconds the pilot flame
will go out.
If there is a risk of freezing, switch off the appliance and
drain the appliance.

Danger:

 the area in front of the burner can reach very high

temperatures, and there is a risk of burning on contact.

3.2

Water temperature control

The water temperature control is used to adjust the water
flow rate, and thereby the water temperature, to the desired
setting.
Turning the control clockwise reduces the water flow rate
and increases the temperature; turning the control anti-
clockwise increases the water flow rate and reduces the
temperature.
If the temperature is set only as high as required, energy
consumption is reduced and the likelihood of scale deposits
in the heat exchanger minimised.

3.3

Appliance adjustments

All instantaneous water heaters are factory-adjusted and
require no further adjustment.*
Water heaters that use LPG (liquefied petroleum gas, i.e.
butane/propane) are set to the operating pressure stated
on the identification plate (2,8 kPa).
Natural gas appliances are set to a Wobbe Index of 15 kWh/
m

3

 and a supply pressure of 2.0 kPa.

Sealed components must not be tampered with

.

3.4

Maintenance

The appliance should only be serviced by an approved
engineer.
A complete overhaul should be carried out after two years.

The overhaul should involve thoroughly cleaning the heat
exchanger, burner, pilot burner and automatic water valve
filter.
If necessary, the inside of the heat exchanger and the
connecting pipes should be descaled.
Check the gas and water valves for leaks and carry out a
complete function check.
If components need to be replaced, 

use only genuine Bosch

spare parts.

3.5

Flue gas safety device

The recommition must be done from a qualified technician
only.
The flue gas safety device must not under any circumstances
be switched off, simulated or replaced by any other
component.

Operation and safety precautions

The flue gas safety device checks the effectiveness of flue
gas extraction by the flue. If it is inadequate, the appliance
switches off automatically so that the combustion fumes do
not escape into the room in which the appliance has been
installed. The flue gas safety device resets after a cooling-
down period.
If the appliance shuts down while in operation, ventilate the
room. Wait about 10 minutes then restart the appliance. If
the problem recurs, call an engineer. The user must never
make any modifications to the appliance.

Maintenance

If faults occur on the flue gas safety device, proceed as
follows:
- Undo flue gas safety device fixing screw.
- Undo magnetic unit connector
- Remove thermocouple.
Replace damaged component with new one and refit using
the reverse of the procedure set out in the table above.

Function check

*

Flue gas safety device function check:
- Disconnect flue pipe
- Replace with pipe (about 50 cm long) with sealed end
- Fit pipe vertically
- Start up appliance at rated output and set temperature

control to maximum temperature.

Under those conditions, the appliance should shut down
after two minutes. Remove temporary pipe and reconnect
flue pipe.
* This work may only be carried out by an approved engineer.

3.6

Converting to a different gas type

Use only the 

genuine Bosch conversion kit

. Conversion

may only be carried out by an approved technician.

Summary of Contents for W11P

Page 1: ...ate room From outside call the gas company and your approved installer Do not use or store easily combustible materials in the vicinity of the appliance Installation and servicing of the appliance may only be carried out by an approved technician The appliance should be regularly serviced in order to ensure that it remains in perfect and safe working order If there is a risk of freezing the applia...

Page 2: ...pliance design 3 1 6 Technical characteristics 4 2 Preconditions for installation 5 2 1 Regulations 5 2 2 Location 5 2 3 Fixing the appliance 5 2 4 Water connection 5 page page 1 Technical Characteristics and Dimensions 1 1 General Description This water heater is fitted with a piezo system Guaranteed safety provided by Gas tight ionisation detector that prevents escape of gas if there is no flame...

Page 3: ...lve 8 Water throttle 9 Water filter 10 Membrane 11 Cold water pipe 12 Magnetic valve 13 Gas supply pipe 14 Gas filter 15 Regulating screw 16 Pilot filter 17 Piezo 18 Hot water pipe 19 Output control 20 Igniter button 21 Main gas valve 22 Gas valve for pilot burner 23 Pilot burner injector 24 Gas valve 25 Jet pressure testing point 26 Thermocouple 27 Igniter electrode 28 Temperature limiter 29 Flue...

Page 4: ... heat input Qmin Btu h 36200 46105 58912 Supply pressure Natural gas mbar kPa 20 2 0 20 2 0 20 2 0 LPG butane propane mbar kPa 28 2 8 28 2 8 28 2 8 Consumption Natural gas m3 h 2 2 2 77 3 5 LPG butane propane kg h 1 75 2 2 2 79 Number of injectors 12 14 18 Max water pressure pw psi 170 170 170 Temperature control at maximum setting Temperature increase C 50 0 50 0 50 0 Flow rate l min 5 5 7 8 8 Mi...

Page 5: ...e control and the output control Remove the outer case by sliding it forwards and then lifting upwards Fix the appliance using the sleeves and hooks supplied so that it is vertical Never allow the appliance to rest against water or gas pipes 2 4 Water connection It is advisable to drain the appliance before installing it as any dirt or grit inside it could reduce the water flow rate and in extreme...

Page 6: ...propane are set to the operating pressure stated on the identification plate 2 8 kPa Natural gas appliances are set to a Wobbe Index of 15 kWh m3 and a supply pressure of 2 0 kPa Sealed components must not be tampered with 3 4 Maintenance The appliance should only be serviced by an approved engineer A complete overhaul should be carried out after two years The overhaul should involve thoroughly cl...

Page 7: ...t appliance If problem recurs call an approved technician Temperature limiter has tripped Wait 10 minutes then restart appliance If problem recurs call an approved technician Water not hot enough Check output selector position and regulate according with needs Water not hot enough weak flame Gas supply dynamic pressure too low Check gas cylinder governor and replace if incompatible or damaged Chec...

Page 8: ... the piezo igniter Repeat these steps if the flame does not stay alight Switching off Release the slide control knob after approximately 15 seconds Move slide control to the far left Turning control anti clockwise increases water flow rate and reduces water temperature Turning control clockwise reduces water flow rate and increases water temperature Temperature adjustment ...

Reviews: