50
en | Configuration using a Web browser
VOT-320
DOC | V4.5 | 2010.09
Installation and Operating Manual
Bosch Sicherheitssysteme GmbH
Export to FTP
Select this parameter if you want all alarm recordings to be exported to an FTP server
automatically. Make sure to have inserted all relevant data for FTP posting (see
Section 5.37 Advanced Mode: FTP Posting, page 76
).
Alarm input / Motion/Audio alarm / Video loss alarm
Here you can select the alarm sensor that is to trigger a recording.
Virtual alarm
Here you can select the virtual alarm sensors that are to trigger a recording, via RCP+
commands or alarm scripts, for example.
5.21
Advanced Mode: Retention Time
You can specify the retention times for recordings. If the available memory capacity of a
medium has been used, older recordings are only overwritten if the retention time entered
here has expired.
Recording 1 / Recording 2
Enter the required retention time in hours or days for each recording.
Recording 1
corresponds to Stream 1,
Recording 2
corresponds to Stream 2.
NOTICE!
The alarm inputs are configured and activated on the
Alarm Inputs
page (see
Section 5.31 Advanced Mode: Alarm Inputs, page 66
).
The numbering of the checkboxes for the alarm inputs corresponds to the labeling of the
alarm inputs on the VOT-320.
The motion alarm is configured and activated on the
VCA
page (see
Section 5.25 Advanced
Mode: VCA, page 56
onwards).
NOTICE!
For more information, please see the
Alarm Task Script Language
document and the RCP+
documentation. These documents can be found on the product CD supplied.
NOTICE!
Make sure that the retention time corresponds with the available memory capacity. A rule of
thumb for the memory requirement is as follows: 1 GB per hour retention time with 4CIF for
complete frame rate and high image quality.
Summary of Contents for VOT-320
Page 1: ...VOT 320 VOT 320V0xxx en Installation and Operating Manual ...
Page 2: ......
Page 115: ......