24
en | Troubleshooting
VIP X16 XF E
F.01U.281.864 | V2 | 2012.12
Installation Manual
Bosch Sicherheitssysteme GmbH
RJ45 socket LEDs
7.5
Processor load
If the VIP X16 XF E encoder is accessed via the Web browser, you will see the processor load
indicator bar in the top right of the window next to the information icon
.
You can obtain additional information to help you when troubleshooting or fine tuning the
unit. The values indicate the proportions of the individual functions on the coder load, shown
as percentages.
Move the cursor over the graphic indicator. Some additional numerical values are also
displayed.
7.6
Network connection
You can display information about the network connection. To do this, move the cursor over
.
7.7
Terminal block
The terminal block has several contacts for:
–
Serial data transmission
–
4 alarm inputs
–
1 relay output
Pin assignment serial interface
Options for using the serial interface include transferring transparent data, controlling
connected units or operating the unit with a terminal program.
The serial interface supports the RS-232, RS-422 and RS-485 transmission standards. The
mode used depends on the current configuration. The pin assignment of the serial interface
depends on the interface mode used.
Left LED flashes (as
ACTIVITY
LED):
Traffic on the network.
Right LED lights up (as
LINK
LED):
Network connection established.
Link
Ethernet link type
UL
Uplink, speed of the outgoing data traffic
DL
Downlink, speed of the incoming data traffic
Contact
RS-232 mode
RS-422 mode
RS-485 mode
CTS
—
RxD- (receive data minus)
—
TXD
TxD (transmit data)
TxD- (transmit data minus)
Data-
RTS
—
TxD+ (transmit data plus)
Data+