background image

VIP X16 XF E

VIP-X16XF-E

en

Installation Manual

Summary of Contents for VIP-X16XF-E

Page 1: ...VIP X16 XF E VIP X16XF E en Installation Manual ...

Page 2: ......

Page 3: ...of functions 8 3 4 Connections controls and displays 11 3 4 1 Front view 11 3 4 2 Rear view 12 4 Installation 13 4 1 Preparations 13 4 2 Installing in a switch cabinet 13 5 Connection 15 5 1 Connecting cameras 15 5 2 Establishing the network connection 16 5 3 Connecting audio 16 5 4 Connecting alarm inputs and relay output 17 5 5 Creating a serial connection 18 5 6 Power on power off 19 6 Configur...

Page 4: ...systeme GmbH 7 8 Copyrights 25 8 Maintenance 26 8 1 Updates 26 8 2 Factory reset 26 8 3 Repairs 26 9 Setting out of order 27 9 1 Transfer and disposal 27 10 Technical data 28 10 1 Electrical 28 10 2 Mechanical 28 10 3 Environmental conditions 28 10 4 Certifications and approvals 28 10 5 Standards 29 ...

Page 5: ...ing installation Relevant knowledge of network technology is required to install the unit Before installing or operating the unit make sure you have read and understood the documentation for the other equipment connected to it such as cameras The documentation contains important safety instructions and information about permitted uses Perform only the installation and operation steps described in ...

Page 6: ...nstallation Manual Bosch Sicherheitssysteme GmbH Ensure that all maintenance or repair work is carried out only by qualified personnel electrical engineers or network technology specialists In case of doubt contact your dealer s technical service center ...

Page 7: ...ernal alarm sensors Other applications are not permitted In the event of questions concerning the use of the unit which are not answered in this manual please contact your sales partner or Bosch Sicherheitssysteme GmbH Robert Bosch Ring 5 85630 Grasbrunn Germany www boschsecurity com 2 4 EU Directives The VIP X16 XF E encoder complies with the requirements of EU Directives 89 336 Electromagnetic C...

Page 8: ...ta for transfer over an IP network With its encoding in the H 264 format the unit is ideally suited for making existing analog CCTV cameras IP compatible and for remote access to digital VCRs and multiplexers The use of existing networks means that integration with CCTV systems or local networks can be achieved quickly and easily Video images from a single sender can be received simultaneously on ...

Page 9: ...s increase the quality on alarm saving recording space during non alarm periods Multicast In suitably configured networks the multicast function enables simultaneous real time video transmission to multiple receivers The UDP and IGMP V2 protocols must be implemented on the network for this function Access security The VIP X16 XF E encoder offers various security levels for accessing the network th...

Page 10: ...6 analog BNC composite video inputs PAL NTSC Video encoding to international standard H 264 Deinterlacing at video input and progressive encoding Integrated Ethernet port 10 100 1000 Base T Network attached iSCSI recording Transparent bidirectional data channel via RS 232 RS 422 RS 485 serial interface Configuration and remote control of all internal functions via TCP IP also secured via HTTPS Pas...

Page 11: ...d displays 3 4 1 Front view Further topics Section 7 4 LEDs page 23 1 Factory reset button to restore factory default settings 2 LED ACTIVITY flashes during data transmission 3 LED LINK lights up when the unit is connected to the network 4 LED STATUS lights up during startup 5 LED CONNECT lights up when supplied with power after startup ...

Page 12: ... connecting the video source 2 ETH RJ45 socket for connecting to an Ethernet LAN local network 10 100 1000 MBit Base T 3 AUDIO IN audio connection mono 3 5 mm 1 8 in stereo socket audio in for connecting two audio sources 4 Terminal block for alarm inputs relay output and serial interface 5 AUDIO OUT audio connection mono 3 5 mm 1 8 in stereo socket line out for connecting one audio connection 6 P...

Page 13: ...g 1 Prepare the switch cabinet in such a manner that you are easily able to insert the unit directly at the installation point 2 Place the cage nuts in the corresponding drillings or spaces in the switch cabinet frame 3 Lift the unit into the switch cabinet frame and insert the fastening screws together with the washers 4 Tighten the screws one after the other and then check once more that all the...

Page 14: ...14 en Installation VIP X16 XF E F 01U 281 864 V2 2012 12 Installation Manual Bosch Sicherheitssysteme GmbH ...

Page 15: ...ameras You can connect a maximum of 16 video sources to the VIP X16 XF E encoder Any cameras and other video sources that produce a standard PAL or NTSC signal are suitable Connect each of the cameras or other video sources to BNC sockets Video In 1 to Video In 16 using a video cable 75 Ohm BNC plug Note that termination is always on ...

Page 16: ...5 2 Establishing the network connection You can connect the VIP X16 XF E encoder to a 10 100 1000 Base T network using a standard UTP category 5 cable with RJ45 plugs Connect the unit to the network via the ETH socket 5 3 Connecting audio The VIP X16 XF E encoder has two audio ports for audio line signals ...

Page 17: ... not activated by default To use audio connections activate the corresponding setting when configuring the unit 5 4 Connecting alarm inputs and relay output Alarm inputs The VIP X16 XF E encoder has four alarm inputs on the terminal block The alarm inputs are used to connect to external alarm devices such as door contacts or sensors With the appropriate configuration an alarm sensor can automatica...

Page 18: ...utomatically activate sirens or other alarm units in response to an alarm signal The relay output is also located on the terminal block 1 Connect the lines to the appropriate terminals R on the terminal block and check that the connections are secure 2 Connect the terminal block to the socket on the unit observing the labeling Further topics Section 7 7 Terminal block page 24 5 5 Creating a serial...

Page 19: ...rminal block to the socket on the unit observing the labeling Further topics Section 7 7 Terminal block page 24 5 6 Power on power off The VIP X16 XF E is delivered together with two power cords one for EU one for US mains socket outlets 1 Select the suitable power cord and connect it to the unit 2 Plug the power cord into the mains The unit is ready for use as soon as the CONNECT LED lights up Pr...

Page 20: ...the program 1 Download Bosch Video Client from the Bosch product catalog on the Internet 2 Unzip the file 3 Double click the installer file 4 Follow the instructions on the screen to complete the installation Configuring the unit You can start Bosch Video Client immediately after installation 1 Double click the icon on the desktop to start the program Alternatively start the application via the St...

Page 21: ...k and set additional parameters with the assistance of the Configuration Manager application in Bosch Video Client You can find detailed information on this in the documentation for these applications Note that the audio function is not activated by default To use audio connections activate the corresponding setting when configuring the unit ...

Page 22: ...Faulty data transmission within the LAN Check the data transmission with e g ping The maximum number of connections has been reached Wait until there is a free connection and then call the unit again No audio transmission to remote station Hardware fault Check that all connected audio units are operating correctly Faulty cable connections Check all cables plugs contacts and connections Incorrect c...

Page 23: ...ty fields Active proxy server in network Create a rule in the local computer s proxy settings to exclude local IP addresses The STATUS LED flashes Firmware upload failed Repeat firmware upload Malfunction Possible causes Recommended solution Malfunction Possible causes Recommended solution After connecting to the iSCSI target no LUNs are displayed Incorrect LUN mapping during iSCSI system configur...

Page 24: ...sor over 7 7 Terminal block The terminal block has several contacts for Serial data transmission 4 alarm inputs 1 relay output Pin assignment serial interface Options for using the serial interface include transferring transparent data controlling connected units or operating the unit with a terminal program The serial interface supports the RS 232 RS 422 and RS 485 transmission standards The mode...

Page 25: ...rpose and without fee is hereby granted provided that the above copyright notices appear in all copies and that both those copyright notices and this permission notice appear in supporting documentation and that the names of Adobe Systems and Digital Equipment Corporation not be used in advertising or publicity pertaining to distribution of the software without specific written prior permission So...

Page 26: ...nter the IP address of the unit as URL in the Web browser and use the Download button on the SETTINGS Advanced Mode Service Maintenance configuration page 2 Using a pointed object press the factory reset button located on the front panel until the STATUS LED flashes All settings will revert to their defaults 3 The unit is ready for use as soon as the CONNECT LED lights up 4 See the relevant chapte...

Page 27: ...our Bosch product is designed and manufactured with high quality materials and components which can be recycled and reused This symbol means that electrical and electronic equipment at their end of life should be disposed of separately from your household waste In the European Union there are separate collection systems for used electrical and electronic products Please dispose of this equipment a...

Page 28: ... 2 mono in microphone line 1 mono line out Signal line in 9 kohm typical 5 5 Vp p max microphone amplifier 60 dB max Signal line out 3 0 Vp p at 10 kohm typical Ethernet 10 100 1000 Base T auto sensing half full duplex RJ45 COM port 1 RS 232 RS 422 RS 485 bidirectional push in terminal Alarm 4 push in terminal input non isolated closing contact activation resistance 10 ohm max Relay 1 push in term...

Page 29: ...aneous unicast multicast Image resolutions PAL NTSC 4CIF 704 576 480 GOP structure I IP Total delay 260 ms typical Dual Streaming Full performance on first stream limited frame rate on second stream Frame rate 1 to 25 30 ips PAL NTSC Audio standards G 711 L16 AAC LC Audio frequency rate G 711 300 Hz to 3 4 kHz L16 300 Hz to 6 4 kHz AAC LC 300 Hz to 6 4 kHz Audio sampling rate G 711 8 kHz L16 16 kH...

Page 30: ...30 en Technical data VIP X16 XF E F 01U 281 864 V2 2012 12 Installation Manual Bosch Sicherheitssysteme GmbH ...

Page 31: ......

Page 32: ...Bosch Sicherheitssysteme GmbH Robert Bosch Ring 5 85630 Grasbrunn Germany www boschsecurity com Bosch Sicherheitssysteme GmbH 2012 ...

Reviews: