Configuration using a Web Browser
Bosch Security Systems | 2005-05 | V1.0
Note
For automatic connections, always Stream 2 is transmitted. Take this into
account when assigning the profile (see page 55).
Relay
You can configure the switching behavior of the relay output. Open switch relay
(normally closed contact) or a closed switch relay (normally open contact) can
be specified.
It is also possible to specify whether the output should in a bistable or
monostable manner. In bistable operation, the activated state of the relay is
maintained. In monostable operation, the time can be selected after which the
relay reverts to its idle state.
You can choose various events that activate the output automatically. Thus, for
example, it is possible to switch on a spotlight in response to a motion alarm and
switch it off again when the alarm is over.
Idle state:
Select
Open
if the relay is to operate as a normally open contact or
Closed
if it
is to operate as a normally closed contact.
Operating mode:
Select an operating mode for the relay.
If, for example, a lamp switched on by an alarm is to remain lit when the alarm
has ended, select
Bistable
. If an acoustic signal activated by an alarm is to
sound for a period of ten seconds for example, select
10 sec.