Installation and User Guide |
VIP X1/VIP X2
EN
| 60
Configuration using a Web Browser
Bosch Security Systems | 2005-05 | V1.0
Alarm sources
You can configure the possible alarm triggers for the VIP X (for example the
alarm inputs).
Alarm input 1 … Alarm input 4:
Select the option
On
in order to activate the alarm via the corresponding external
alarm sensor. Otherwise, select
Off
.
Select
Active high
if the alarm is to be triggered by closing the contact. Select
Active low
if the alarm is to be triggered by opening the contact.
Name:
You can enter a name for each alarm input, which is then displayed below the
icon for the alarm input on the
LIVEPAGE
during configuration (see
Livepage
configuration
, page 71).
Video loss alarm:
Click the check box if you want interruption of the video signal to trigger an
alarm. A selected video input is marked with a tick.
Note
The numbering corresponds to the labeling of the video inputs on the
actual unit (VIP X2 only).