110
en | Recording
AUTODOME IP starlight 7000 HD
2016-07 | 1.0 | F.01U.283.679
Operation Manual
Bosch Security Systems
Recording includes
You can specify whether, in addition to video data and metadata (for example alarms, VCA
data and serial data) should also be recorded. Including metadata could make subsequent
searches of recordings easier but it requires additional memory capacity.
!
Caution!
Without metadata, it is not possible to include video content analysis in recordings.
Standard recording
Here you can select the mode for standard recordings.
If you select
Continuous
, the recording proceeds continuously. If the maximum memory
capacity is reached, older recordings will automatically be overwritten. If you select the
Pre-
alarm
option, recording will only take place in the pre-alarm time, during the alarm and during
the set post-alarm time.
If you select
Off
, no automatic recording takes place.
!
Caution!
You can specify limitations for overwriting older recordings in
Continuous
mode by
configuring the retention time (see Retention Time).
Stream
Select the stream to be used for standard recordings:
–
Stream 1
–
Stream 2
–
I-frames only
Alarm recording
Pre-alarm time
You can select the required pre-alarm time from the list field.
Post-alarm time
You can select the required post-alarm time from the list field.
Alarm stream
Select the stream to be used for alarm recordings:
–
Stream 1
–
Stream 2
–
I-frames only
Encoding interval and bit rates from profile
Select this checkbox and then select an encoder profile to set the associated encoding
interval for alarm recording.
Alarm triggers
Alarm input / Analysis alarm / Video loss
Here you can select the alarm sensor that is to trigger a recording.
Virtual alarm
Here you can select the virtual alarm sensors that are to trigger a recording, via RCP+
commands or alarm scripts, for example.