32
en | Installing a Recessed Mount
AutoDome Easy II
F.01U.139.424 | 2.0 | 2009.08
User Manual
Bosch Security Systems, Inc.
6.
Insert mount through the hole and into the ceiling. Slide
clamps out and down so that the drywall is clamped in
between the clamps and the bracket flange (41.7 mm
(1.64 in.) maximum ceiling thickness and 12.7 mm
(0.50 in.) minimum ceiling thickness).
Figure 6.4
Attach Recess Mount to Ceiling
7.
Tighten both clamps to the ceiling using supplied screws
and a #2 Phillips screwdriver.
Figure 6.5
Tighten Mounting Clamps
NOTICE!
Over torquing the ceiling clamps can damage the
clamp or ceiling. Only tighten the clamp until it contacts the
ceiling and you start to feel some resistance. If using a power
screwdriver, set the torque level to the lowest setting.