32
en | Operation via Keyboard and OSD Menus
Dinion Infrared Imager
F.01U.263.417 | 3.0 | 2012.01
User Manual
Bosch Security Systems, Inc.
2.
Traffic
Capture high-speed objects using default shutter in
variable lighting conditions.
3.
Low light
Provide extra enhancement such as AGC and SensUp to
make usable pictures in low-light conditions.
4.
Smart BLC
Settings optimized to capture details in high contrast and
extremely bright-dark conditions.
5.
Low noise
Enhancements are set to reduce picture noise. Useful for
conditional refresh DVR and IP storage systems because
reducing noise reduces the amount of storage required.
6.
Infrared
Settings are configured to provide optimal imaging
performance in low-light or no-light conditions.
6.3
Camera control communication (Bilinx)
This camera is equipped with a coaxial communications
transceiver (also referred to as Bilinx). In combination with VP-
CFGSFT, the camera setting can be changed from any point
along the coaxial cable. All menus can be accessed remotely
giving full control of the camera. With this method of
communication it is also possible to disable the local keys on
the camera. To avoid loss of communication on an installed
camera, the
Communication On/Off
selection is not available
while using remote control. This function can only be accessed
with the camera buttons. Bilinx communications can only be
disabled using the buttons on the camera.
Disabled camera buttons
When the Bilinx communications link is active, the buttons on
the camera are disabled.