en | Configuring the System
High Speed Pan/Tilt System
F01U.073.990 | Version 1.0 | 2007.07
Instruction Manual
Bosch Security Systems
11.3.2
Limits
The
Limits
menu sets the movement limits for the UPH. These limits apply to all presets, auto-
pan and patrols, including manual operation of the UPH using the joystick. After the limits are
set in the OSD and the UPH moves into the "limited pan and tilt zone", it will not move outside
of those limits until they are altered in the OSD or the UPH is reset. On reset, the UPH returns
to within the limited pan and tilt zone.
.
LIMITS MENU
1 - ENABLE PAN LIM.
:
NO
2 - START PAN
: +
0.00
3 - END PAN
: +
0.00
4 - ENABLE TILT LIM.
:
NO
5 - START TILT
: +
0.00
6 - END TILT
: +
0.00
7 - COMPL. ROTATION
:
YES
8 - RAMP TYPE
:
012
Fig. 11.10
Limits Menu
Feature
Description
Default
Options
ENABLE PAN LIM.
Enables limits and values in
degrees taken by the device in
pan.
Enables or disables complete rota-
tion for scan/patrol/autopan move-
ments (this function is useful when
using accessories with external
cables, such as infrared spotlights,
where continuous rotation of the
UPH could break the accessories
themselves).
NO
YES, NO
START PAN
Enables the location that the UPH
begins to pan.
+0.00
-180.00
°
-
+180.00
°
END PAN
Enables the location that the UPH
stops panning.
+0.00
-180.00
°
-
+180.00
°
ENABLE TILT LIM.
Enables limits and values in
degrees taken by the device in tilt.
NO
YES, NO
START TILT
Enables the location that the UPH
begins to tilt.
+0.00
-40.00
°
-
+90.00
°
END TILT
Enables the location that the UPH
stops tilting.
+0.00
-40.00
°
-
+90.00
°
COMPL. ROTATION
Enables the search for the shortest
route during scan, patrol, and
autopan movements.
YES
YES, NO
RAMP TYPE
Changes start and stop times for
the UPH. The higher the number,
the greater the acceleration/decel-
eration during starting/stopping.
012
000 - 012