Product Information

 

Uni Condens 8000 F – 6720867069 (2016/10)

4

H

Combustion/room air

▶ Keep the combustion/ambient air free of corrosive 

substances (e.g. halogenated hydrocarbons that 
contain chlorine or fluorine compounds). This will 
help to prevent corrosion.

▶ Keep the combustion air supply free of dust.

H

Danger posed by explosive and easily 
flammable materials

▶ Never use or store easily flammable materials (e.g. 

paper, thinners, paints, etc.) near the appliance.

H

Heating system damage due to frost

When the heating system is not in operation (e.g. 
controller switched off, fault shutdown), there is a risk 
of it freezing when there is frost.

▶ When shutting down or switching off for extended 

periods, drain the heating and drinking water pipes 
to the lowest point in order to protect the heating 
system from freezing.

H

Inspection and servicing

Recommendation for customers:

 Arrange a 

maintenance and inspection contract with an 
approved contractor, covering an annual inspection 
and responsive maintenance.

▶ The user is responsible for ensuring the heating 

system is safe and environmentally compatible.

▶ Immediately correct all faults to prevent system 

damage!

▶ Use only genuine spare parts from the 

manufacturer. Losses caused by the use of spare 
parts and accessories not supplied by the 
manufacturer are excluded from the manufacturer's 
warranty.

H

Handover to the user

When handing over, instruct the user how to operate 
the heating system and inform the user about its 
operating conditions.

▶ Explain how to operate the heating system and draw 

the user's attention to any safety relevant action

▶ Explain that conversions and repairs must only be 

carried out by a competent person.

▶ Point out the need for inspections and maintenance 

for safe and environmentally-compatible operation.

▶ Leave the installation instructions and the 

operating instructions with the user for 
safekeeping.

2

Product Information

2.1

Declaration of Conformity

The design and operation of this product comply with European 
Directives and the supplementary national requirements. Conformity 
has been demonstrated by the CE marking.

You can ask for a copy of the declaration of conformity for this product. 
For this see the contact address on the back cover of these instructions.

2.2

Determined use

The Uni Condens 8000 F 800...1200 floor standing condensing boiler 
has been designed for wet heating systems in (e.g. apartment buildings 
or industrial applications).

The boiler is only approved for open-flue mode.

When installing and operating the heating system:
• Comply with standards, regulations and guidelines of the relevant 

country.

• Observe the information on the data plate of the boiler.

2.3

Symbol at the boiler

2.4

Data plate

If you contact the manufacturer with any questions about this product, 
always provide the details on the data plate. If we have these details, we 
can quickly answer your specific query.
The details on the data plate are binding and must be observed!

You will find information such as the serial number, output and approval 
details on the data plate.

2.5

Product Description

The Uni Condens 8000 F 800...1200 is a floor standing condensing 
boiler with a slim, compact design and a small footprint, comprising a 
combustion chamber located at the top and a condensation heating 
surface located at the bottom.

With the Uni Condens 8000 F 800...1200 floor standing condensing 
boilers, all parts that come into contact with products of combustion or 
condensate are made from high grade stainless steel. This makes 
operation possible without limitations on the flow and return 
temperature, the flow rate or the burner low load.

The Uni Condens 8000 F 800...1200 is also referred to in this manual as 
UC8000F 800...1200, boiler or heat source.

The boiler has two separate thermohydraulic return connections for the 
high and low temperature heating circuits (

 fig. 1, page 5).

The Uni Condens 8000 F 800...1200 must be equipped with a burner 
that is suitable for the boiler. 

The main components of the boiler are (

 fig. 1, page 5):

• Boiler shell [1] in conjunction with a burner 

The boiler block transfers the heat produced by the burner to the 
heating water.

• Thermally insulating casing 

The boiler shell and thermal insulation reduce energy losses.

• Control unit (accessory) [8]

The control unit monitors and controls all electrical boiler 
components.

This symbol is used to point out that the installation and 
operating instructions must be read prior to installation 
operation or maintenance in order to prevent damage to the 
system.

Summary of Contents for Uni Condens 8000 F UC8000F

Page 1: ...6720867069 2016 10 GB IE Operating instructions for users Floor standing condensing boiler Uni Condens 8000 F UC8000F 800 1200 kW ...

Page 2: ...heating controller etc prior to operation Observe the safety instructions and warnings 1 Explanation of symbols and safety instructions 2 1 1 Explanation of symbols 2 1 2 General safety instructions 2 2 Product Information 4 2 1 Declaration of Conformity 4 2 2 Determined use 4 2 3 Symbol at the boiler 4 2 4 Data plate 4 2 5 Product Description 4 2 6 Permissible fuels 5 2 7 Operation conditions 6 2...

Page 3: ...lified person so that risks are avoided H Risk through oil leaks If using oil as fuel country specific regulations hold the operator responsible for asking a contractor to correct any oil leaks the moment they are discovered H If you smell gas Close gas isolation valve Open windows and doors Do not touch any electrical switch telephone and do not use outlets Extinguish any naked flames Do not smok...

Page 4: ...ity for this product For this see the contact address on the back cover of these instructions 2 2 Determined use The Uni Condens 8000 F 800 1200 floor standing condensing boiler has been designed for wet heating systems in e g apartment buildings or industrial applications The boiler is only approved for open flue mode When installing and operating the heating system Comply with standards regulati...

Page 5: ...ure return 14 Inspection opening on the water side both sides 15 Flow safety line 16 Heating flow 17 Boiler safety assembly accessories 18 Lifting points 2 6 Permissible fuels The boiler must only be operated with the specified fuels Only burners that are suitable for the specified fuels may be used Gas burner The combustion of biogas is not permitted Permissible fuels Natural gas from the public ...

Page 6: ...ere should be a maximum of 6 burner starts per hour averaged over burnerruntimeononeday Ifthenumberofstartsishigher theuser should be notified The system must be checked to find out whether thenumberofburnerstartscanbereduced Thecustomerserviceof the manufacturer can provide assistance with optimisation of the system 2 9 Burner requirements Only use specified pressure jet gas burners with floor st...

Page 7: ...d guidelines Observe the information on the data plate of the boiler 3 1 Combustion air quality To avoid corrosion keep the supply of combustion air free of corrosive substances e g halogenated hydrocarbons that contain chlorine or fluorine compounds Never use or store chlorinated cleaning agents or halogenated hydrocarbons as contained in spray cans solvents or cleaning agents paints and adhesive...

Page 8: ... e g due to a fault shutdown and there is a risk of frost drain the heating water at the DFV Also leave the air vent at the highest point in the heating system open 5 1 Shutting down the heating system The heating system is shut down via the control unit The burner is also automatically shut down Switch off the burner at the control unit 5 2 Shutting down the heating system in an emergency Only sw...

Page 9: ...nted correctly Check the heating system for leaks and the expansion vessel for functionality Observe the requirements regarding water quality operator s log If water loss occurs frequently locate the cause and rectify the problem without delay NOTICE System damage due to temperature stresses Onlyfilltheheatingsystemwhencold theflowtemperaturemustnot exceed 40 C During operation only fill the heati...

Page 10: ...Further information on the fault displays can be found in the service instructions of the relevant controlunit Inaddition burnerfaultsaresignalledbyanindicatoronthe burner Press burner reset button see operating instructions of burner and control If the burner still fails to start after three attempts contact a contractor 8 2 Other faults For other possible faults see the installation and operatin...

Page 11: ......

Page 12: ...Bosch Thermotechnik GmbH Junkersstrasse 20 24 D 73249 Wernau www bosch thermotechnology com ...

Reviews: