docnumber | V 2.0 | 2007.01

Important safety instructions

Read, follow, and retain for future reference all of the following safety 

instructions. Heed all warnings on the unit and in the operating instructions 

before operating the unit.
1.

Cleaning - Unplug the unit from the outlet before cleaning. Follow any 

instructions provided with the unit. Generally, using a dry cloth for 

cleaning is sufficient, but you can also use a moist fluff-free cloth or 

leather shammy. Do not use liquid cleaners or aerosol cleaners.

2.

Heat Sources - Do not install the unit near any heat sources such as 

radiators, heaters, stoves, or other equipment (including amplifiers) 

that produce heat.

3.

Ventilation - Any openings in the unit enclosure are provided for ventila-

tion to prevent overheating and ensure reliable operation. Do not block 

or cover these openings. Do not place the unit in an enclosure unless 

proper ventilation is provided, or the manufacturer's instructions have 

been adhered to.

4.

Object and liquid entry - Never push objects of any kind into this unit 

through openings as they may touch dangerous voltage points or short-

out parts that could result in a fire or electrical shock. Never spill liquid 

of any kind on the unit. Do not place objects filled with liquids, such as 

vases or cups, on the unit.

5.

Lightning - For added protection during a lightning storm, or when leav-

ing this unit unattended and unused for long periods, unplug the unit 

from the wall outlet and disconnect the cable system. This will prevent 

damage to the unit from lightning and power line surges.

6.

Overloading - Do not overload outlets and extension cords. This can 

cause fire or electrical shock.

7.

Power cord and plug protection - Protect the plug and power cord from 

foot traffic, being pinched by items placed upon or against them at 

electrical outlets, and its exit from the unit. For units intended to oper-

ate with 230 VAC, 50 Hz, the input and output power cord must comply 

with the latest versions of 

IEC Publication 227

 or 

IEC Publication 245

.

8.

Power disconnect - Units with or without ON/OFF switches have power 

supplied to the unit whenever the power cord is inserted into the 

power source; however, the unit is operational only when the ON/OFF 

switch is in the ON position. The power cord is the main power discon-

nect device for switching off the voltage for all units.

9.

Power sources - Operate the unit only from the type of power source 

indicated on the label. Before proceeding, be sure to disconnect the 

power from the cable to be installed into the unit.

For battery powered units, refer to the operating instruc-

tions.

Summary of Contents for UHI-OG-0

Page 1: ...UHI UHO Series UHI OG 0 UHI OGS 0 UHO HGS 10 UHO HBGS 10 UHO HBPS 10 UHO HGS 50 UHO HBGS 50 UHO HPS 50 UHO HBPS 50 UHO HBGS 60 en User Manual ...

Page 2: ......

Page 3: ...r cord 14 4 3 3 Lens control cable 15 4 4 Housing mounting 15 4 5 Opening the cover 16 4 6 Camera Lens installation 16 4 7 Camera Lens wiring 18 4 7 1 Fittings 18 4 7 2 Conduit 19 4 7 3 Feed through Wiring 19 4 7 4 Power Connections 20 4 8 Video coax connection 24 4 9 Lens wiring 25 4 10 Camera Lens adjustment 25 4 11 Final assembly 25 4 12 Sunshield 26 4 13 Fuse replacement 26 5 UHO HBPS 10 50 an...

Page 4: ...4 en UHI UHO Series docnumber V 2 0 2007 01 User Manual Bosch Security Systems 6 Operation 28 7 Maintenance 28 8 Exploded view 29 ...

Page 5: ...ck Never spill liquid of any kind on the unit Do not place objects filled with liquids such as vases or cups on the unit 5 Lightning For added protection during a lightning storm or when leav ing this unit unattended and unused for long periods unplug the unit from the wall outlet and disconnect the cable system This will prevent damage to the unit from lightning and power line surges 6 Overloadin...

Page 6: ...power supply cord or plug is damaged exposure to moisture water and or inclement weather rain snow etc liquid has been spilled in or on the equipment an object has fallen into the unit unit has been dropped or the unit cabinet is damaged unit exhibits a distinct change in performance unit does not operate normally when the user correctly fol lows the operating instructions 12 Replacement parts Be ...

Page 7: ...4 7 4 Power Connections Camera lens An assembled camera lens in the outdoor housing must com ply and be tested in accordance with UL IEC60950 Any output or signal lines from the camera must be SELV or Limited Power Source For safety reasons the environmental specification of the camera lens assembly must be within the environmental specification of 10 C 14 F to 50 C 122 F DANGER High risk This sym...

Page 8: ...rds the environment This unit has been designed to respect the environment as much as possible Electrostatic sensitive device Use proper CMOS MOS FET handling precau tions to avoid electrostatic discharge NOTE Wear required grounded wrist straps and observe proper ESD safety precautions when handling the elec trostatic sensitive printed circuit boards Outdoor signals The installation for outdoor s...

Page 9: ...nergy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications How ever there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to corr...

Page 10: ...10 en UHI UHO Series docnumber V 2 0 2007 01 User Manual Bosch Security Systems ...

Page 11: ...rvice See www boschsecuritysystems com Qty Item Part 1 Housing with correct model number ABS 1 Spacer 4 mm ABS 1 Spacer 9 mm ABS 2 Screw 1 4 20 x 1 4 in SS 2 Screw 1 4 20 x 3 8 in SS 2 Screw 1 4 20 x 3 4 in SS 2 Screw 1 4 20 x 5 8 in SS 2 Screw 1 4 20 x 7 16 in SS 2 Screw 1 4 20 x 1 2 in SS 3 Screw tamper resistant M3 5 T15 1 Wrench tamper resistant M3 5 T15 1 Camera tray part A PS 1 Camera clamp ...

Page 12: ...30 VAC Max camera lens size HWD 91 x 81 x 262 mm 3 6 x 3 2 x 10 3 in Table 3 1 Indoor units UHO HGS 10 UHO HBGS 10 UHO HBPS 10 Installed accessory Htr SS Htr Blr SS Htr Blr SS 4 pin Voltage range power 21 6 to 25 4 VAC 40 W Camera ratings 24 VAC Max camera lens size HWD 91 x 81 x 262 mm 3 6 x 3 2 x 10 3 in Table 3 2 Outdoor 24 volt units UHO HBGS 60 Installed accessory Htr Blr SS Voltage range pow...

Page 13: ...nal Electrical Code or applicable local codes CAUTION These units must be properly and securely mounted to a supporting structure capable of sustaining the unit weight Use care when selecting mounts or pan tilts not supplied for installation the mounting surface and unit s weight should be carefully considered Ambient temperature 0 C to 50 C 32 F to 122 F Power consumption 10 W max Voltage for low...

Page 14: ...ce RG 59 U RG 11 U 15 ohm 1000 m 6 ohm 1000 m Cable impedance 75 ohm Certificating authority UL Environmental Outdoor rated Temperature rating 80 C 176 F or greater Reference type Belden 9259 Table 4 2 Video cable specifications Cable type 3 x 18 AWG Cable diameter outer 4 6 to 7 9 mm 0 18 to 0 31 in Cable shape Round Conductors 3 or 2 Voltage rating 300 V Certificating authority UL C S A UL VW 1 ...

Page 15: ...ing to all other mounts and pan tilts See Figure 4 1 Cable type H05RN F 3 G 0 75 H05RN F 3 G 1 00 Cable diameter outer 4 6 to 7 9 mm 0 18 to 0 31 in Cable shape Round Conductors 3 or 2 Voltage rating 300 V Certificating authority VDE Environmental Outdoor rated Reference type Olflex rubber cable 1600 252 Olflex rubber cable 1600 253 Table 4 4 Power cord specifications for Europe Cable type Jackete...

Page 16: ... screws have been installed use the supplied wrench to remove the screws before opening the latches Fig 4 2 Unlatching the cover 4 6 Camera Lens installation 1 Remove the two screws holding the camera tray to the housing Remove tray from the housing 2 If using the feed through feature refer to Section 4 7 3 Feed through Wiring For mounting with feed through wiring For mounting with rear connection...

Page 17: ...ras in all housings c Attach the lens to the camera d Combine the 4 mm and the 9 mm spacers provided to mount the camera to the optional camera tray type A use different combinations of the spacers to ensure that the camera lens is in the middle of the window Use the 1 4 20 x 5 8 in screw and large flat washer to secure the camera and spacer to the camera tray as shown in Figure 4 3 e Slide the ca...

Page 18: ...3 2 Outdoor 24 volt units and Section 3 4 Outdoor 230 volt units for UHO HBPS 10 UHO HPS 50 and UHO HBPS 50 models 4 7 1 Fittings The 3 8 inch NPT fitting accepts a round cable with diameter from 4 0 mm 0 16 in to 7 0 mm 0 28 in The two larger 1 2 inch NPT fittings accept cables with diame ters from 6 5 mm 0 26 in to 10 5 mm 0 42 in CAUTION Use only cables meeting specifications in Section 4 3 Cab...

Page 19: ... two dome plugs located inside the housing See Figure 4 6 Fig 4 6 Location of feed through wiring holes 2 Screw the two 3 8 inch NPT fittings into the foot of the housing 3 Pull the cabling through the fittings into the housing Tighten the fitting to 4 0 Nm to 4 5 Nm 35 inch lb to 40 inch lb This torque rating is approximately 1 to 1 5 turns past the point where the fitting starts to grip the CAUT...

Page 20: ... to accommodate the terminal block 1 If using the feed through option ignore this step Install one of the large 1 2 inch NPT fittings into one of the holes in the rear cap 2 Route the power cable through the fitting in the rear cap or one of the feed through fittings in the foot The terminal block accepts wire ranging from 0 5 mm2 to 2 5 mm2 20 AWG to 14 AWG When using larger wire sizes splice to ...

Page 21: ...ure 4 7 Fig 4 7 Safety grounding 4 Pull any excess wire out of the housing and tighten the fit ting to 8 5 Nm to 9 0 Nm 75 inch lb to 80 inch lb This torque rating is approximately one to one and a half turns past the point where the fitting starts to grip the wire CAUTION For compliance with safety regulations the external ground wire must always be connected to the main ground post Nut Lock wash...

Page 22: ... power cord on 120 VAC and 230 VAC camera mod els leave enough cable to allow connection to the terminal block Strip no less than 6 mm 0 25 in and no more than 8 mm 0 31 in of insulation away from the wire Be sure not to nick the wires Connect these wires to the connec tors provided on the terminal block See Figure 4 8 CAUTION Be sure to securely tighten all fittings to ensure a liquid tight seal ...

Page 23: ...0 for indicating recommended locations and wiring methods FUSE L L L N N N G G G 1 2 x L N To camera Ground test connector Do NOT disconnect To accessories BNC cable to camera Ground cable to housing top Ground stud housing bottom Power input grounding post Lens wiring Power input connector Lens Video input connector Pin Color Connection N Blue Power connection L Brown Power connection G Green G s...

Page 24: ...wire out of the housing and tighten the fit ting to 8 5 Nm to 9 0 Nm 75 inch lb to 80 inch lb This torque rating is approximately one to one and a half turns past the point where the fitting starts to grip the wire CAUTION For security protection of the device the branch circuit protection must be secured with a maximum fuse rating of 16A This must be in accordance with NEC 800 CEC Section 60 CAUT...

Page 25: ... the rear of the housing Wire the required functions For correct plug connection see specification on lens cord 4 10 Camera Lens adjustment Verify operation of the camera and lens before final assembly Adjust the camera focus and iris as necessary See camera installation manual 4 11 Final assembly 1 Use the hole plugs provided to plug any unused holes in the rear cap 2 Replace the camera and brack...

Page 26: ...ld to the desired position It has a range of 50 mm 2 in 3 Tighten the screws to lock the sunshade into position 4 If the sunshield is removed or not installed plug the two screw holes with the hole plugs supplied with the housing hardware kit 4 13 Fuse replacement 1 To replace a fuse pull the top of the fuse holder 2 Replace the fuse with a fuse that has the same current rating The fuse is a 5 mm ...

Page 27: ...n to the terminal block Strip no less than 6 mm 0 25 in and no more than 8 mm 0 31 in of insulation away from the wire Be sure not to nick the wires 2 Insert the power cord through the back shell assembly and strain relief See Figure 5 1 Fig 5 1 Mating connector 4 pin assembly CAUTION Use only 24 VAC power for UHO HBPS 10 models These models have female connectors to prevent them from being connec...

Page 28: ...r of the housing Connect video cable to the housing using a BNC connec tor 2 An internal video connection is provided Connect the BNC cable to the camera 6 Operation These housings require no operational adjustments other than camera lens adjustments 7 Maintenance No special maintenance is required other than occasional clean ing the window The window can be cleaned with water or any non aggressiv...

Page 29: ...UHI UHO Series Exploded view en 29 Bosch Security Systems User Manual F 01U 026937 V 2 0 2007 01 8 Exploded view Fig 8 1 Exploded view ...

Page 30: ...RP24 120 VAC JRP12 230 VAC JRP23 4 Bottom cover plus latches 4 pin version XD4P1 10 Bracket for UHI series FZ001 Bracket PCB 24 VAC heater no blower FZP24 Bracket PCB 24 VAC heater incl blower FPF24 Bracket PCB 230 VAC heater no blower FZP23 Bracket PCB 230 VAC heater incl blower FPF23 Bracket PCB 120 VAC heater incl blower FPF12 5 Front window holder QG001 11 Camera tray zoom lens version SP001 C...

Page 31: ......

Page 32: ...Bosch Security Systems Robert Koch Straße 100 D 85521 Ottobrunn Germany Telefon 089 6290 0 Fax 089 6290 1020 www boschsecuritysystems com Bosch Security Systems 2007 ...