Bosch TR5000R 18/21 EAB Installation Instructions Manual Download Page 9

Technical data

9

6 720 891 048 (2019/01)

3

Technical data

* Larger cable cross-sections may be required depending on the 
connection configuration.
** The pressure loss on the mixer must also be added.

3.1

Solar heated

Only for appliances that are suitable for solar heating systems:

 

The appliance can only heat prewarmed water to a max. of 60 °C. 
If the cold water supply exceeds a temperature of 55 °C, the water will 
not be warmed any further.

Important: 

The cold water supply temperature must not be higher 

than 55 °C! 

If the cold water supply exceeds a temperature of 60 °C, a circuit breaker 
will trigger and shut the appliance off. Therefore, the residential 
plumbing must be equipped with a thermostatic premixer (e. g. special 
accessory 

BZ 45T20

) that will limit the cold water supply temperature 

to a max. of 55 °C by appropriately mixing in cold water.

Dimensions

 

(Fig. 

 9

)

4

Special accessories

• Pipe kit

 BZ 45U20

 for use of the appliance as an under-sink 

appliance

• Priority switch (load shedding relay) 

BZ 45L21

for operation with a priority circuit

• Mounting kit 

BZ 45K23

: for surface mount installation

Only for appliances that are suitable for solar heating systems

:

Thermostatic premixer

 BZ 45T20

: for installation in the domestic 

plumbing when using preheated water

5

Environmental protection/disposal

Environmental protection is a fundamental corporate strategy of the 
Bosch Group. 
The quality of our products, their economy and environmental safety are 
all of equal importance to us and all environmental protection legislation 
and regulations are strictly observed.
We use the best possible technology and materials for protecting the 
environment taking account of economic considerations.

Packaging

Where packaging is concerned, we participate in country-specific 
recycling processes that ensure optimum recycling. 
All of our packaging materials are environmentally compatible and can be 
recycled.

Used appliances

Used appliances contain valuable materials that can be recycled. 
The various assemblies can be easily dismantled. Synthetic materials are 
marked accordingly. Assemblies can therefore be sorted by composition 
and passed on for recycling or disposal.

Used electrical and electronic appliances

Electrical or electronic devices that are no longer 
serviceable must be collected separately and sent for 
environmentally compatible recycling (in accordance with 
the European Waste Electrical and Electronic Equipment 
Directive).

To dispose of old electrical or electronic devices, you 

should use the return and collection systems put in place in the country 
concerned.

Batteries must not be disposed together with your household waste. 
Used batteries must be disposed of in local collection systems.

TR5000R 18/21 

EAB

TR5000R 24/27 

EAB

TR7000R 18/21 

DESOAB

TR7000R 24/27 

DESOAB

Rated output

[kW]

15/21

21/27

15/21

21/27

Rated voltage

[V]

400

400

400

400

Fuse protection

[A]

32

40

32

40

Minimum conductor cross-section*

[mm

2

]

4

6

4

6

Warm water flow at rated output

with temperature increase from
12 °C to 38 °C (without flow-rate limiter) 
12 °C to 38 °C (with flow-rate limiter) 
12 °C to 60 °C

[l/min]
[l/min]
[l/min]

9.8/11.6

7.6

5.3/6.2

13.0/14.6

9.3

7.1/7.9

9.8/11.6

7.6

5.3/6.2

13.0/14.6

9.3

7.1/7.9

Start-up flow

[l/min]

2.5

2.5

2.5

2.5

Start-up flow pressure**

[MPa (bar)]

0.04 

0.4

0.04 

0.4

0.04

0.4

0.04

0.4

Application area in water 
specific electric resistance at 15 °C

[Ωcm]

≥ 1 300

≥ 1 300

≥ 1 300

≥ 1 300

Rated pressure

[MPa (bar)]

1.0 (10)

1.0 (10)

1.0 (10)

1.0 (10)

Maximum permissible supply temperature

[°C]

20

20

55

55

Maximum mains impedance at connection point

[Ω]

0.067/0.104

0.067/0.104

0.067/0.104

0.067/0.104

Energy efficiency class

A

A

A

A

Load profile

S

S

S

S

Annual energy consumption

[kWh]

479

479

479

479

Daily energy consumption

[kWh]

2.203

2.207

2.203

2.207

Sound power level

[dB]

15

15

15

15

Hot water heating energy efficiency

[%]

38.5

38.5

38.5

38.5

Summary of Contents for TR5000R 18/21 EAB

Page 1: ...048 2019 01 DIV TR5000R TR7000R TR5000R 18 21 EAB TR5000R 24 27 EAB TR7000R 18 21 DESOAB TR7000R 24 27 DESOAB de Montageanleitung 2 en Installation instructions 6 fr Notice de montage 10 pl Instrukcja montażu 15 ...

Page 2: ...omschlaggefahr SchaltenSieimFehlerfallsofortdieNetzspannung ab Vor dem Öffnen des Gerätes die Stromzufuhr zum Gerät unterbrechen Bei einer Undichtigkeit am Gerät sofort die Kalt wasserleitung schließen Diese Installationsanleitung richtet sich an Fachleute für Wasserinstallationen Heizungs und Elektrotech nik Die Anweisungen in allen Anleitungen müssen ein gehalten werden Bei Nichtbeachten können ...

Page 3: ...ab 3 Jahren und darü ber sowie von Personen mit verringerten physischen sensorischen oder mentalen Fähigkeiten oder Mangel an Erfahrung und Wissen benutzt werden wenn sie beaufsichtigt oder bezüglich des sicheren Gebrauchs desGerätesunterwiesenwurdenunddiedarausresul tierendenGefahrenverstehen Kinderdürfennichtmit dem Gerät spielen Reinigung und Benutzer Wartung dürfen nicht von Kindern ohne Beauf...

Page 4: ...schlussklemme festschrauben 2 Sicherheitsbegrenzer einschalten 3 Haube montieren 4 7 Installationshinweis Die Installation nicht steckerfertiger Geräte ist vom jeweiligen Netzbetreiber oder von einem eingetragenen Fachbetrieb vorzu nehmen der Ihnen auch bei der Einholung der Zustimmung des jeweiligen Netzbetreibers für die Installation des Gerätes behilflich ist Inbetriebnahme Bild 7 Das Gerät stim...

Page 5: ...ten Verpackungsmaterialien sind umweltverträglich und wiederverwertbar Altgerät Altgeräte enthalten Wertstoffe die wiederverwertet werden können DieBaugruppensindleichtzutrennen Kunststoffesindgekennzeichnet Somit können die verschiedenen Baugruppen sortiert und wiederver wertet oder entsorgt werden Elektro und Elektronik Altgeräte NichtmehrgebrauchsfähigeElektro oderElektronikgerä te müssen getre...

Page 6: ...t free room due to residual water WARNING Risk of electric shock Switch off the mains voltage supply immediately if a fault occurs Disconnect the power supply before opening the appliance Immediately shut off the cold water supply to the appliance should it leak These installation instructions are intended for plumbers heating engineers and electricians All instructions must be observed Failure to...

Page 7: ...ryormentalcapabilitiesorlackinginexperience and knowledge if they are supervised and have been given instruction in the safe use of the appliance and understand the resulting dangers Children shall not play with the appliance Cleaning and user maintenance must not be performed by children without supervision If the power cable is damaged it must be replaced by the manufacturer its customer service...

Page 8: ...he mains connection terminal 2 Switch on the safety limiter 3 Install the cover 4 7 Installation note The installation of non plug in ready appliances must be undertaken by the respective utility operator or by a qualified specialist company who can also assist you when you are requesting the approval of the utility company for installation of the appliance Startup Fig 7 The device is compliant to ...

Page 9: ...recycling Allofourpackagingmaterialsareenvironmentallycompatibleandcanbe recycled Used appliances Used appliances contain valuable materials that can be recycled Thevariousassembliescanbeeasilydismantled Syntheticmaterialsare markedaccordingly Assembliescanthereforebesortedbycomposition and passed on for recycling or disposal Used electrical and electronic appliances Electrical or electronic devic...

Page 10: ...au résiduelle AVERTISSEMENT Danger de choc électrique En cas d erreur déconnectez immédiatement la tension du secteur Couper l alimentation en courant avant d ouvrir l appareil En cas de fuite sur l appareil immédiatement cou per l alimentation en eau froide Cette notice d installation s adresse aux profession nels d installations gaz et d eau de chauffage et d électronique Les consignes de toutes...

Page 11: ... et utilisations similaires Pour éviter les risques dus aux appareils électriques les prescriptions suivantes s appliquent conformé ment à la norme EN 60335 2 35 Cet appareil peut être utilisé par des enfants à partir de 3 ans ainsi que par des personnes aux capacités physiques sensorielles ou mentales réduites ou dénuées d expérience ou de connaissance s ils si elles sont correctement surveillé e...

Page 12: ...roite 1 et la puissance configurée sur la plaque signalétique Visser à fond les conduites sur la borne de branchement au secteur 2 Activer le limiteur de sécurité 3 Monter le capot 4 7 Remarque sur l installation L installationd appareilspasprêtsaubranchementdoitêtreeffec tuée par l exploitant de réseau ou par une entreprise spécialisée habilitée laquelle vous aide également à obtenir l accord de l...

Page 13: ...és pour le mode solaire Prémélangeur à thermostat BZ 45T20 pour le montage dans l ins tallation domestique lors de l utilisation de l eau préchauffée TR5000R18 21EAB TR5000R24 27EAB TR7000R 18 21DESOAB TR7000R 24 27DESOAB Puissance nominale kW 15 21 21 27 15 21 21 27 Tension nominale V 400 400 400 400 Protection par fusibles A 32 40 32 40 Section de câble minimale mm2 4 6 4 6 Débit d eau chaude po...

Page 14: ...s les matériaux d emballage utilisés respectent l environnement et sont recyclables Appareils usagés Les appareils usés contiennent des matériaux qui peuvent être réutili sés Les composants se détachent facilement Les matières synthétiques sontmarquées Cecipermetdetrierlesdifférentscomposantsenvuede leur recyclage ou de leur élimination Appareils électriques et électroniques usagés Les appareils é...

Page 15: ...ie instalować i przechowywać w pomieszczeniach zabezpieczonych przed mrozem pozostałości wody OSTRZEŻENIE Niebezpieczeństwo porażenia prądem W razie awarii natychmiast wyłączyć zasilanie sieciowe Przed otwarciem urządzenia odłączyć jego zasilanie energią elektryczną W przypadku wystąpienia nieszczelności urządzenia natychmiast zamknąć dopływ zimnej wody Niniejsza instrukcja montażu adresowana jest...

Page 16: ...montażu należy wodoszczelnie zatkać nieużywane otwory Po zakończeniu montażu nie może istnieć możliwość dotknięcia elementów pod napięciem Nie używać środków do szorowania lub rozpuszczalników Nie używać myjek parowych Bezpieczeństwoelektrycznychurządzeńdoużytku domowego itp Aby uniknąć zagrożeń powodowanych przez urządzenia elektryczne należy przestrzegać następujących przepisów normy EN 60335 2 ...

Page 17: ...rządzeń z przełączaną mocą Przed podłączeniem przewodów do zacisku przyłącza sieci należy ustawić moc za pomocą przełącznika mocy normalna moc ustawienie z lewej strony zredukowana moc ustawienie z prawej strony 1 i zaznaczyć ustawioną moc na tabliczce znamionowej Przykręcić przewody do zacisku przyłącza sieci 2 Włączyć ogranicznik zabezpieczający 3 Zamontować pokrywę 4 7 Wskazówki instalacyjne In...

Page 18: ... z wykorzystaniem energii słonecznej Mieszacz termostatyczny BZ 45T20 do montażu w instalacji domowej przy korzystaniu z wstępnie podgrzanej wody TR5000R18 21 EAB TR5000R24 27 EAB TR7000R18 21 DESOAB TR7000R24 27 DESOAB Moc znamionowa kW 15 21 21 27 15 21 21 27 Napięcie znamionowe V 400 400 400 400 Zabezpieczenie A 32 40 32 40 Minimalny przekrój przewodów mm2 4 6 4 6 Ilość wody ciepłej przy mocy z...

Page 19: ...e dla środowiska i mogą być ponownie przetworzone Zużyty sprzęt Stare urządzenia zawierają materiały które mogą być ponownie wykorzystane Moduły można łatwo odłączyć Tworzywa sztuczne są oznakowane W ten sposób różne podzespoły można sortować i ponownie wykorzystać lub zutylizować Zużyty sprzęt elektryczny i elektroniczny Zużyty sprzęt elektryczny i elektroniczny musi być gromadzony oddzielnie i p...

Page 20: ...6 720 891 048 2019 01 20 1 ...

Page 21: ...21 6 720 891 048 2019 01 2 ...

Page 22: ...6 720 891 048 2019 01 22 3 ...

Page 23: ...23 6 720 891 048 2019 01 4 ...

Page 24: ...6 720 891 048 2019 01 24 5 ...

Page 25: ...25 6 720 891 048 2019 01 6 7 ...

Page 26: ...6 720 891 048 2019 01 26 8 ...

Page 27: ...27 6 720 891 048 2019 01 9 10 ...

Page 28: ...Bosch Thermotechnik GmbH Junkersstrasse 20 24 D 73249 Wernau www bosch thermotechnology com ...

Reviews: