Installation instructions
6 720 891 048 (2019/01)
8
Water connection (Fig. 4, 5)
▶ Before connecting the water, guide the AquaStop connection pipe
into the grommet (Fig. 5, [
7.
]). The grommet must tightly surround
the connection pipe.
▶ Connect the water supply, then open the cold water supply.
▶ When tightening the connections, make sure that the AquaStop is
positioned vertically.
▶ Press the grip surfaces together and pull out the transport protection
attachment to the right (Fig. 5, [
10.
]).
▶ The appliance must be vented. To do so, open the warm water tap
fully and flush out the appliance thoroughly for 1 minute.
Electrical connection/Mounting
(Fig.
)
Limiting the outlet temperature to 53 °C (Fig. 10).
(Only for the following appliances; TR 5000R and TR 7000R.)
WARNING:
Risk of electric shock!
How to move the temperature limiting switch,
▶ Disconnect the power supply before opening the appliance.
▶ Remove the cover.
▶ Move the temperature limiting switch to the 53°C position (
Only for appliances with power selector switches:
▶ Set the power using the power selector switch before connecting the
wires to the mains connection terminal: Nominal output power left,
reduced output right [
1.
] and the set output marked on the ratings
plate.
▶ Screw the wires tightly into the mains connection terminal [
2.
].
▶ Switch on the safety limiter [
3.
].
▶ Install the cover (
4.–7.
).
Installation note
•
The installation of non plug-in ready appliances must be
undertaken by the respective utility operator or by a qualified
specialist company, who can also assist you when you are
requesting the approval of the utility company for installation
of the appliance.
Startup
(Fig.
)
The device is compliant to IEC 61000-3-12.
First start-up
▶ Switch on the fuses
▶ Setting the temperature.
▶ Initial rinsing: Open the warm water tap fully and allow water to flow
for at least 1 minute. Only then (for safety reasons) will the appliance
begin to heat.
Tip:
Should the appliance not start because of a reduced flow-rate,
remove the perlator, shower head or similar before start and repeat
the process.
• Explain the operation of the appliance to the user.
Additional information
(Fig.
• If the appliance does not have sufficient water flow due to low water
line pressure in your domestic plumbing system, remove the flow-
rate limiter [
1.–3.
].
• Priority circuit for the combination with electrical storage heaters:
For operation with a priority circuit, a special load shedding relay
BZ 45L21 (special accessory) is required. Other existing load
shedding relays, with the exception of electronic load shedding
relays, may malfunction (
Wiring diagram
).
• The control electronics must be coded when operated with
a load shedding relay. Remove the keying nose on the electronics
[
4.
].
Summary of Contents for TR5000R 18/21 EAB
Page 20: ...6 720 891 048 2019 01 20 1 ...
Page 21: ...21 6 720 891 048 2019 01 2 ...
Page 22: ...6 720 891 048 2019 01 22 3 ...
Page 23: ...23 6 720 891 048 2019 01 4 ...
Page 24: ...6 720 891 048 2019 01 24 5 ...
Page 25: ...25 6 720 891 048 2019 01 6 7 ...
Page 26: ...6 720 891 048 2019 01 26 8 ...
Page 27: ...27 6 720 891 048 2019 01 9 10 ...
Page 28: ...Bosch Thermotechnik GmbH Junkersstrasse 20 24 D 73249 Wernau www bosch thermotechnology com ...