6 720 800 095 (2014/05)
Therm 6000S
Installation instructions | 33
Note: Do not count terminals and
first elbow used
on intake and
exhaust.
8.6.2 Adjusting fan speed
After obtaining the
total sum of the conducts, proceed as
follow:
Press ON/OFF button into OFF.
Press and hold "Program" button and press ON/OFF button
to turn appliance ON (see Fig. 47 ).
Fig. 47
As soon as '188' is displayed, release "Program" button
, and the display should read P2.
Press one time
to access the program P2. In the LCD
display is visible the attributed
value (factory value: GN: 8,
LPG:7).
Press
or
to choose the fan speed suitable with
your installation, see tab.20 for separate tubes admission/
exhaust Ø 80/80 mm.
Press and hold ( 5 sec.) “Program” button
until the
display flashes.
Selected value is memorized.
Fan speed for separate tubes Ø80/80 mm
Intake
1
Straight section length _4_ x 1=
4
2
90° elbows (qty)
_1_ x 1 =
1
3
45° elbows (qty)
_0_ x 0.5 =
0
4
30° elbows (qty)
_0_ x 0.4 =
0
5
:l
a
t
o
t
-
b
u
S
5
6
Total equivalent vent length=
12
Table 19
Total maximum length for separate tubes
(exhaust/admission) must not exceed 16
meters.
Mode
Conduct length
1)
1) Total conducts lengths of Table 17. Do not count with the
first elbow and the accessory of wind/rain protection.
Fan speed
GN
LPG
P2
From 1 m until 6 m
8
7
from 6.1 m until 14 m
9
8
from 14.1m until 16 m
10
9
Table 20
Do not set P2 to greater then 10.