26 | TCE 4510 | Adjustments
en
F7 - protection fuse of the 24VAC circuit
3.7.14
In case it blows check that the connection cable of the pedal box is not damaged and that the cables inside are
not interrupted or short-circuited, and that the micro switches on the pedal box are not short-circuited if they are
damaged. Finally, check also the two remote control switches of the rotation mandrel, specially the coils.
With this type of single-phase machinery be very careful when operating on the motor condensers, since they
!
retain for a long time the residual electrical charge, and therefore subsists the danger of electrical discharges of
considerable intensity if they are inadvertently touched.