background image

- 5 -

#6-32 BOLTS

THERMOSTAT

YELLOW
SPACER

TERMINAL
BLOCK

TERMINAL BRACKET

WHITE TERMINAL
COVER CLIP

AIR

HEATERS

PAN/TILT MOUNTING BRACKET

HEATER LEADS

HEATER THERMOSTAT

TERMINAL BLOCK

BLOWER THERMOSTAT

BLOWER

TERMINAL BRACKET

"WING"

TERMINAL
BRACKET

BUSHING

MOUNTING
BRACKET

STUD

SIDE VIEW

ELECTRICAL ACCESSORIES INSTRUCTIONS

The TC9320 (L) housing can be purchased with optional silicon
strip heaters and a muffin-type blower.  The standard housing
includes the terminal block with cover, as well as the terminal
bracket used to mount this equipment to the mounting bracket.

The heater option includes one set of silicon strip heaters,  thermo-
stat, an adapter plate for mounting the heaters to the pan/tilt
mounting bracket, and mounting hardware.

The blower option includes a muffin-type blower and thermostat,
as well as mounting hardware.

Terminal Block

1)

  Place the terminal block bracket over the two threaded studs

protruding out of one of the "wings" on the pan/tilt mounting
bracket.  Refer to Fig. 5 for proper orientation.  Secure with (2)
tooth washers and (2) #4-40 hex nuts.

2)

  Position the terminal block over the two center holes in the

terminal bracket.  Place the (2) white clips on top of the block,
and secure the assembly with (2) #6-32 bolts, as shown in Fig. 6.

  Figure 5

  Figure 6

Strip Heaters
1)

  Mount the heater bracket to the threaded studs on the pan/

tilt mounting plate using (2) tooth washers and (2) #4-40 hex nuts.
Refer to Fig.6 for proper orientation of bracket.

2)

  Position one of the heater strips over the studs on the heater

bracket.  Be certain that the heater is oriented so that the wire
leads point towards the terminal block, with the metal side of the
heater strip touching the heater bracket.  Refer to Fig. 7.

3)

  Place a 1/4-20 hex nut over each studs, to space the two

heater strips apart.  Position the second heater on top of the flat
washers, metal side touching the flat washers.

4)

  Secure the heaters in place using flat washers and #8-32 hex

nuts.

5

)  Push the yellow spacer into the terminal bracket in the hole

nearest the heater strips.  This allows the heater wires to reach the
thermostat.  Mount the heater thermostat on top of the spacer

Summary of Contents for TC9320

Page 1: ...TC9320 TC9320C Instruction Manual EN Indoor Ceiling Housings ...

Page 2: ...cture and falling with resultant damages or injury to anyone or anything struck by the falling unit SAFETY PRECAUTIONS The lightning flash with an arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of non insulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons The exc...

Page 3: ...he instructions on page 3 3 Open the housing packet and remove the 4 2 5 spacers and place them inside the housing over the threaded studs Remove the quick release plate from the mounting bracket and slide the bracket into position over the threaded studs a shown in Fig 1 NOTE If you are using optional heaters and or blower refer to electrical accessories section on page 3 prior to installing moun...

Page 4: ... 2 and 4 7 Connect the drive motor to the break away plate Make sure that the pan tilt is attached to the quick release plate on the same side as the slide latch fateners Position the fasteners on the quick release plate over the bushings on the mounting bracket alreadysecuredtothehousing Engagetheslidelatchfasteners and secure with the 2 8 32 bolts 8 Connect camera and lens to the drive motor and...

Page 5: ...racket Refer to Fig 5 for proper orientation Secure with 2 tooth washers and 2 4 40 hex nuts 2 Position the terminal block over the two center holes in the terminal bracket Place the 2 white clips on top of the block and secure the assembly with 2 6 32 bolts as shown in Fig 6 Figure 5 Figure 6 Strip Heaters 1 Mount the heater bracket to the threaded studs on the pan tilt mounting plate using 2 too...

Page 6: ...r to wiring diagram Fig 8 7 Construct a jumper wire not included using the second female lead and attach it to the second post on the thermostat Connect the other end of the jumper to the terminal block position No 5 Blowers 1 The blower mounts to the underside of the pan tilt mounting plate as shown in Fig 5 Be sure to position the blower so that the air flow is pointing away from the bracket 2 S...

Page 7: ......

Page 8: ...urity Systems Inc 850 Greenfield Road Lancaster PA 17601 USA Tel 800 326 3270 Fax 1 717 735 6560 www boschsecuritysystems com Bosch Security Systems B V P O Box 80002 5600 JB Eindhoven The Netherlands Tele 31 40 27 80000 Bosch Security Systems Pte Ltd 38C Jalan Pemimpin Singapore 577180 Republic of Singapore Tel 65 6 319 3486 ...

Reviews: