en
Fault, what to do?
28
Fault table
Fault
Cause
Remedial action
“Check water supply”
display
8
lights up.
Supply hose kinked.
Install supply hose without kinks.
Tap turned off.
Turn on the tap.
Tap jammed or calcified.
Turn on the tap.
Flow rate must be min. 10 l/min.
when water supply is open.
Filter in the water supply blocked. Switch off the appliance and pull out
the mains plug. Turn off the tap. Unscrew
water connection.
Clean filter in the supply hose. Screw water
connection on again. Check for leaks.
Reconnect power supply. Switch on
the appliance.
Error code
“
:
ƒƒ
is lit.
Filters
1Z
are soiled or
blocked.
Clean filters.
(See Cleaning and maintenance)
Error code
“
:
ƒ…
is lit.
Waste water hose
is blocked or kinked.
Install hose without kinks, remove any
residue.
Siphon connection still sealed.
Check connection to siphon and open if
required.
Cover on the waste water pump
loose.
Lock cover correctly.
(See Waste water pump)
Error code
“
:
Ġ
is lit.
Waste water pump blocked
or cover on the waste water
pump is not locked in position.
Clean pump and lock cover correctly. (See
Waste water pump)
Error code
“
:
ƒˆ
is lit.
Mains voltage too low.
Not an appliance fault, have the mains
voltage and electrical installation checked.