D.R.
©
2019 – HAIER EUROPE SERVICE ITALIA
Any change or alteration whatsoever of this document is formally prohibited except with the previous consent of the issuer.
1
TECHNICAL NOTE N. 00267/LB – 18/10/2019
The following test routine procedure is valid for both washing machines and washer dryers
from the Candy Rapidò range which will be available to the market from May 2019
1) Preliminary activation fase
Plug the machine using “the self-diagnostic
shuko patch cord extension P/N: 91941051
(See Picture 1). Connect the patch cord
extension to the power supply.
By the cables with connector supplied with
the patch cord extension ( See Picure 1 - Ref
“A”), connect to the Amperometric bushings
(Ref. ”B”) a multimeter set to Ammeter
(maximum full scale).
2) Test activation
Open the porthole and visually check that the TUB IS
EMPTY (during the test the out of balance sensor is
disabled).
To activate the test procedure you must reset the
language menu selection as shown below:
Move the program knob in any program press
simultaneously and hold down the option buttons
“STEAM” and “START DELAY” until the display
showing “ENGLISH” (see Picture 2)
Move the program knob in “OFF”,
then turn it to the second position on the right
(see Picture 3)
SUBJECT:
“RAPIDO” – ACTIVATION OF TEST ROUTINE PROCEDURE
Picture 1
1
Cod: 91941051
Picture 3
Picture 2