CC408 |
Quick Reference Guide | 3. Programming Parameters
EN
| 16
Bosch Security Systems | 6/04 | 4998152468B
3.11.7 Pulsing
Mode
When you program the output polarity as pulsing,
the time base becomes the ON time and the
multiplier becomes the OFF time. The OFF time is
the time base, which is multiplied by the
multiplier. For example, if you want the output to
pulse 1 second ON and 5 seconds OFF, you would
program time base as one and the multiplier as
five.
3.12 Time
Programming
3.12.1
Entry Time 1
Location
398 to 399
Location
Default
Increments of 1 second
(0 to 15 seconds)
398 4
Increments of 16 seconds
(0 to 240 seconds)
399 1
3.12.2
Entry Time 2
Location
400 to 401
Location
Default
Increments of 1 second
(0 to 15 seconds)
400 8
Increments of 16 seconds
(0 to 240 seconds)
401 2
3.12.3
Exit Time (AWAY/STAY Modes)
Location
402 to 403
Location
Default
Increments of 1 second
(0 seconds to 15 seconds)
402 12
Increments of 16 seconds
(0 seconds to 240 seconds)
403 3
3.12.4
Entry Guard Time For STAY Mode
Location
404 to 405
Location
Default
Increments of 1 second
(0 seconds to 15 seconds)
404 0
Increments of 16 seconds
(0 seconds to 240 seconds)
405 0
3.12.5
Delay Alarm Report Time
Location
406 to 407
Location
Default
Increments of 1 second
(0 seconds to 15 seconds)
406 0
Increments of 16 seconds
(0 seconds to 240 seconds)
407 0
3.12.6
Sensor Watch Time
Location
408 to 409
Location
Default
Increments of days
(tens digit)
408 0
Increments of days
(units digit)
409 0
3.12.7
Codepad Lockout Time
Location
410
Default
0
0 No
lockout
1 to 15
Increments of 10 seconds
(10 seconds to 150 seconds)
3.12.8
Siren Run Time
Location
411
Default
5
0
No siren time
1 to 15
Increments of 1 minute
(1 minute to 15 minutes)
3.12.9
Siren Sound Rate
Location
412
Default
7
0 to 15
0 = slowest frequency
15 = fastest frequency
3.12.10
Auto Arming Pre-Alert Time
Location
413
Default
1
0
No pre-alert time
1 to 15
Increments of 5 minutes
(5 minutes to 75 minutes)
3.12.11
Auto Arming Time
Location
414 to 417
Location
Default
Hour of the day (tens digit)
414
0
Hour of the day (units digit)
415 0
Minute of the day (tens digit)
416
0
Minute of the day (units digit)
417 0
3.12.12
Auto Disarming Time
Location
418 to 421
Location Default
Hour of the day (tens digit)
418
0
Hour of the day (units digit)
419
0
Minute of the day (tens digit)
420
0
Minute of the day (units digit)
421
0
3.12.13
Kiss-Off Wait Time
Location
422
Default
3
Increments of 500 milliseconds
(500 ms to 8 seconds)
3.13 Reserved
Location
423
Default
0
3.14 System Options Programming
3.14.1
System Options 1
Location
424
1
Bosch Security Systems smart lockout allowed
2
Horn speaker monitor
4
Strobe indication for radio arm/disarm
8
Horn speaker beeps for radio arm/disarm