3.11.7 Pulsing 

Mode 

When you program the output polarity as pulsing, 
the time base becomes the ON time and the 
multiplier becomes the OFF time. The OFF time is 
the time base, which is multiplied by the 
multiplier. For example, if you want the output to 
pulse 1 second ON and 5 seconds OFF, you would 
program time base as one and the multiplier as 
five. 

3.12 Time 

Programming 

3.12.1 

Entry Time 1 

Location

 

398 to 399 

 Location

 

Default

 

Increments of 1 second  
(0 to 15 seconds) 

398 4 

Increments of 16 seconds  
(0 to 240 seconds)

 

399 1 

3.12.2 

Entry Time 2 

Location

 

400 to 401 

 Location

 

Default

 

Increments of 1 second  
(0 to 15 seconds) 

400 8 

Increments of 16 seconds  
(0 to 240 seconds)

 

401 2 

3.12.3 

Exit Time (AWAY/STAY Modes) 

Location

 

402 to 403 

 Location

 

Default

 

Increments of 1 second  
(0 seconds to 15 seconds) 

402 12 

Increments of 16 seconds  
(0 seconds to 240 seconds)

 

403 3 

3.12.4 

Entry Guard Time For STAY Mode 

Location

 

404 to 405 

 Location

 

Default

 

Increments of 1 second  
(0 seconds to 15 seconds) 

404 0 

Increments of 16 seconds  
(0 seconds to 240 seconds)

 

405 0 

3.12.5 

Delay Alarm Report Time 

Location

 

406 to 407 

 Location

 

Default

 

Increments of 1 second  
(0 seconds to 15 seconds) 

406 0 

Increments of 16 seconds  
(0 seconds to 240 seconds)

 

407 0 

3.12.6 

Sensor Watch Time 

Location

 

408 to 409 

 Location

 

Default

 

Increments of days  
(tens digit) 

408 0 

Increments of days  
(units digit)

 

409 0 

 

3.12.7 

Codepad Lockout Time 

Location

 

410 

Default

 

0 No 

lockout 

1 to 15 

Increments of 10 seconds  
(10 seconds to 150 seconds) 

3.12.8 

Siren Run Time 

Location

 

411 

Default

 

No siren time 

1 to 15 

Increments of 1 minute  
(1 minute to 15 minutes) 

3.12.9 

Siren Sound Rate 

Location

 

412 

Default

 

0 to 15 

0 = slowest frequency 
15 = fastest frequency 

3.12.10 

Auto Arming Pre-Alert Time 

Location

 

413 

Default

 

No pre-alert time 

1 to 15 

Increments of 5 minutes  
(5 minutes to 75 minutes) 

3.12.11 

Auto Arming Time 

Location

 

414 to 417 

 Location

 

Default

 

Hour of the day (tens digit) 

414 

Hour of the day (units digit)

 

415 0 

Minute of the day (tens digit) 

416 

Minute of the day (units digit)

 

417 0 

3.12.12 

Auto Disarming Time 

Location

 

418 to 421 

 

Location Default 

Hour of the day (tens digit) 

418 

Hour of the day (units digit) 

419 

Minute of the day (tens digit) 

420 

Minute of the day (units digit) 

421 

3.12.13 

Kiss-Off Wait Time 

Location

 

422 

Default

 

Increments of 500 milliseconds  
(500 ms to 8 seconds)  

 

3.13 Reserved 

Location

 

423 

Default

 

3.14  System Options Programming 

3.14.1 

System Options 1 

Location

 

424 

Bosch Security Systems smart lockout allowed 

Horn speaker monitor 

Strobe indication for radio arm/disarm 

Horn speaker beeps for radio arm/disarm 

Summary of Contents for Solution 880 CC408

Page 1: ...EN Quick Reference Guide Solution 880 CC408 ...

Page 2: ...d above or where authorised by the Copyright Act 1968 Cth no part of this publication may be reproduced transmitted modified or stored in any form or by any means without the prior written permission of Bosch Notice of Liability While every precaution has been taken in the preparation of this document neither Bosch Security Systems Pty Ltd nor any of its official representatives shall have any lia...

Page 3: ...1 3 Handshake Tone for Receiver 1 9 3 1 4 Transmission Format for Receiver 1 9 3 1 5 Subscriber ID Number for Receiver 1 9 3 1 6 Phone Number 1 Receiver 2 9 3 1 7 Phone Number 2 Receiver 2 9 3 1 8 Handshake Tone for Receiver 2 9 3 1 9 Transmission Format for Receiver 2 9 3 1 10 Subscriber ID Number for Receiver 2 9 3 1 11 Dialling Format 9 3 1 12 Reserved 9 3 1 13 Telco Arming Sequence Call Forwar...

Page 4: ...tem Options 3 17 3 14 4 System Options 4 17 3 15 Consumer Options Programming 17 3 15 1 Consumer Options 1 17 3 15 2 Consumer Options 2 17 3 15 3 Consumer Options 3 17 3 16 Radio Input Options 17 3 17 Partioning 17 3 17 1 Partitioning Options 1 17 3 17 2 Partitioning Options 2 17 3 18 Zone Allocation Programming 17 3 18 1 Zone Allocations for Area 1 17 3 18 2 Zone Allocations for Area 2 17 3 19 Us...

Page 5: ...rogramming Mode The codepad indicators display the current data programmed in LOCATION 000 the first location of the Primary Telephone Number Move to another programming location by entering the location number followed by the key The data in the new location is displayed using the codepad indicators for example entering 3 4 moves you to LOCATION 034 the beginning of the Subscriber ID Number For R...

Page 6: ...e allowed 4 Answering machine bypass only when armed 8 Use Bell 103 for FSK format disabled CCITT V21 2 Installer s Programming Commands Installer s programming commands are only used in Installer s Programming Mode Enter the command followed by the key Table 4 shows the installer s programming commands Table 4 Installer s Programming Commands Command Description 958 Enable disable zone status han...

Page 7: ... if more than one zone must be isolated 3 Press the key to exit when finished 2 3 2 Code to Isolate 1 Press the key once 2 Enter your user code 3 Enter the zone number to isolate followed by the key Repeat Step 2 if more than one zone must be isolated 4 Press the key to exit when finished 2 4 Set First Test Report 1 Enter the Installer Code followed by the 1 and keys for example 1 2 3 4 1 2 Enter ...

Page 8: ...Date and Time 1 Enter the Master Code followed by the 6 and keys for example 2 5 8 0 6 2 Enter the day DD month MM and year YY followed by the hour HH and minute MM 3 Press the key to exit 2 13 Day Alarm Toggle On Off Press and hold the 4 key until two beeps sound Day alarm toggles on or off 2 14 STAY Mode 2 Zones Program 1 Enter the Installer Code or Master Code followed by the 4 and keys for exa...

Page 9: ... 10 and telephone termination 0 Anywhere else 0 0 3 1 3 Handshake Tone for Receiver 1 Location 032 1 HI LO handshake contact ID 2 1400 Hz Ademco TX 1900 Hz 3 2300 Hz Sescoa TX 1800 Hz 4 No handshake 5 Pager 3 1 4 Transmission Format for Receiver 1 Location 033 1 Contact ID 2 4 2 expressed 3 FSK 300 baud 4 Domestic 5 Basic pager 3 1 5 Subscriber ID Number for Receiver 1 Location 034 to 039 Default ...

Page 10: ...Close Reports for STAY Mode 1 and STAY Mode 2 4 Delay siren until transmission complete 8 Extend handshake wait time from 30 seconds to 55 seconds 3 1 20 Dialler Options 3 Location 179 Default 0 1 Set DTMP dialling pulses to 1 digit second 2 Reserved 4 Change decadic dialling to 60 40 8 Reserved 3 2 Alarm Link Options Location 180 1 Upload download allowed 2 Call back phone number required for upl...

Page 11: ...K 12 Reserved 13 Reserved 14 Reserved 15 Split EOL 3K3 6K8 Eight burglary zones 3 7 Zone Default Programming 3 7 1 Zone Defaults Location 267 to 322 Location Default Zone 01 Default Delay 1 Zone Type 267 2 Zone Pulse Count 268 0 Zone Pulse Count Time 269 0 Zone Option 1 270 1 Zone Option 2 271 14 Report Code 272 1 Dialler Options 273 1 Zone 02 Default Handover Zone Type 274 1 Zone Pulse Count 275 ...

Page 12: ... seconds 7 15 seconds 15 200 seconds 3 7 5 Zone Options 1 Option Description 1 Lockout siren dialler 2 Delay Alarm Report 4 Silent alarm 8 Sensor watch 3 7 6 Zone Options 2 Option Group 1 Isolated in STAY Mode 1 2 Zone isolation allowed 4 Forced arming allowed 8 Zone Restore Report allowed 3 7 7 Zone Dialler Options Option Description 0 No Zone Reports allowed 1 Report to Receiver 1 2 Report to Re...

Page 13: ...rt to Receiver 2 only if Receiver 1 fails 3 10 3 Codepad Duress Report Location 336 Default 6 3 10 4 Codepad Panic Report Location 337 to 338 Location Default Tens digit 337 7 Units digit 338 15 3 10 5 Codepad Fire Report Location 339 to 340 Location Default Tens digit 339 7 Units digit 340 14 3 10 6 Codepad Medical Report Location 341 to 342 Location Default Tens digit 341 7 Units digit 342 13 3 ...

Page 14: ... 2 Default Fire alarm with verification Event Code 374 2 Event Code 375 7 Polarity 376 10 Time Base 377 2 Time Base Multiplier 378 1 Time Base Multiplier 379 5 3 11 1 continued Location 368 to 397 Location Default Strobe Output Default Strobe reset after 8 hours Event Code 380 2 Event Code 381 0 Polarity 382 6 Time Base 383 4 Time Base Multiplier 384 0 Time Base Multiplier 385 8 Relay Output Defau...

Page 15: ...ins cycle 60 Hz or 50 Hz 4 10 Area 1 zone unsealed 4 11 Area 2 zone unsealed 4 12 Reserved 4 13 Reserved 4 14 Reserved 4 15 Reserved 3 11 2 continued Event Code Description 5 0 Reserved 5 1 Reserved 5 2 Area 1 in alarm 5 3 Area 2 in alarm 5 4 Reserved 5 5 Reserved 5 6 Area 1 armed 5 7 Area 2 armed 5 8 Reserved 5 9 Reserved 5 10 Area 1 disarmed 5 11 Area 2 disarmed 5 12 Reserved 5 13 Reserved 5 14 ...

Page 16: ...5 seconds 406 0 Increments of 16 seconds 0 seconds to 240 seconds 407 0 3 12 6 Sensor Watch Time Location 408 to 409 Location Default Increments of days tens digit 408 0 Increments of days units digit 409 0 3 12 7 Codepad Lockout Time Location 410 Default 0 0 No lockout 1 to 15 Increments of 10 seconds 10 seconds to 150 seconds 3 12 8 Siren Run Time Location 411 Default 5 0 No siren time 1 to 15 I...

Page 17: ...odepad duress alarm instead of digit 9 4 Alarms activate sirens and strobe outputs in STAY Modes 1 and 2 8 Reserved 3 16 Radio Input Options Location 431 Default 0 1 Radio receiver WE800 2 Latching keyswitch input 3 Momentary keyswitch input 4 Reserved 3 17 Partioning 3 17 1 Partitioning Options 1 Location 432 Default 0 1 First to open last to close reporting allowed 2 Area 1 codepad connected to ...

Page 18: ...s 749 6 3 21 Default Options Location 900 0 Defaulting system allowed 15 Defaulting system disabled 3 22 System Time Location 901 to 904 Location Default Hour of the day tens digit 901 0 Hour of the day units digit 902 0 Minute of the day tens digit 903 0 Minute of the day units digit 904 0 3 23 System Date Location 905 to 910 Location Default Day of the month tens digit 905 0 Day of the month uni...

Page 19: ...1 2 3 4 5 6 7 8 1 Zone 1 2 Zone 2 3 Zone 6 4 Zone 3 5 Zone 7 6 Zone 8 7 Zone 4 8 Zone 5 Figure 4 Split EOL Wiring Diagrams Using N O Contacts 2 2 1 3 3 1 4 6 5 7 8 8 4 6 10 8 9 1 12 V 2 Zone input 3 Zone 4 EOL 3K3 5 EOL 1K5 6 EOL 6K8 7 EOL 4K7 8 N O 9 N C 10 4K7 Figure 5 Wiring Diagram for Keyswitch Zone 1 2 1 Zone 2 Keyswitch momentary toggle ...

Page 20: ...lecom line street 5 Yellow Internal phone line 3 and 4 Not used 2 Black Telecom line street 1 Green Internal phone line 3 Zone 1 4 Zone 5 5 Zone 2 6 Zone 6 7 Power to external equipment 12 V 400 mA 8 PIR 9 Zone 8 10 Zone 4 11 Zone 7 12 Zone 3 13 Piezo siren 14 Smoke detector 15 Strobe 16 Horn speaker 17 Codepad 18 Yellow 19 Green 20 Red 21 Black 22 Battery 23 18 VAC 1 3 A plug pack TF008 24 Link b...

Page 21: ...e IN both terminals Telecom line street OUT both terminals Internal phone line 3 Socket for Telecom lead connection 4 Zone termination strip 5 Output termination strip 6 Battery input 7 Plug pack input Bosch TF008 8 Relay contact select 9 1 A codepad fuse 10 1 A accessory fuse 11 3 A battery fuse 12 Default switch 13 Programming key or hand held programmer plugs in here 14 Auxiliary module phone a...

Page 22: ... 0 If the CP 5 Area Addressable CP500A codepad is assigned to Area 2 DIP Switch 2 on the back of the remote codepad must be in the ON position The following locations for Output 1 must be programmed LOCATION 368 6 369 1 A master partitioned codepad requires all DIP switches to be set to the ON position The following DIP Switch settings and locations must be programmed for the two CP 5 Area Address...

Page 23: ... Master Partitioned CP500P Codepad and CP 5 Area Addressable CP500A Codepad 1 DATA 2 CLK 3 12V 4 GND 5 Addressable Area Codepad 6 Master Partitioned Codepad Figure 10 Connections for Two CP 5 Eight Zone Area Addressable CP500A Codepads 1 DATA 2 CLK 3 12V 4 GND 5 Area 2 Codepad 6 Area 1 Codepad 1 1 2 3 4 5 6 1 1 2 3 4 5 6 ...

Page 24: ... 2004 Bosch Security Systems 4998152468B S1920057 Issue 1 62 Bosch Security Systems 25 Huntingwood Drive Huntingwood 2148 Australia Phone 612 9672 1777 Facsimile 612 9672 1717 ...

Reviews: