The RECORD MODE SET UP menu will appear.
ALARM REC MODE
This defines the alarm recording mode option. When
an alarm occurs, the VCR will record the alarm at the
selected tape speed 6H, 18H or 30H, and then revert
back to the real-time recording speed.
3. Press the MOVE button to choose the ALARM
REC MODE option.
4. Press the SELECT button to select alarm recording
hours.
ALARM REC TIME
This defines the amount of time that the alarm is
recorded, 30 sec., 1 min., 5 min., 10 min., LEVEL* or
T.END.
5. Press the MOVE button to choose the ALARM
REC TIME option.
6. Press the SELECT button to select the desired time
of recording, 30 sec., 1 min., 5 min., 10 min.,
LEVEL* or T.END (Tape end).
Notes:
*
If you choose the LEVEL, alarm recording is
activated in three different ways:
a. When an alarm is activated the alarm will be
recorded for 30 sec.
b. When an alarm has been activated, and a second
alarm is initiated within the first 30 sec period, the
alarm recording will be activated for 30 sec. from
the start of the second alarm.
c. If a continuous alarm input is generated, then the
alarm recording is also continuous until the input is
closed.
Therefore, when the LEVEL option is selected, the
minimum alarm recording is 30 sec.
•
If you choose the T.END, alarm recording is
continued until tape end is reached.
•
While the alarm is in process, the buzzer will ring.
If you want to stop buzzer, press CLEAR button.
•
The ALARM indicator in VCR indicator panel will
appear when the alarm recording is proceeding.
1SHOT REC
This defines the interval time that one picture is
recorded, 1 sec., 3 sec., 5 sec., 15 sec., 30 sec., 60 sec.
or OFF.
Notes:
•
If you select the '000H' option in normal recording,
the VCR will activate the '1SHOT REC' mode
function. This will record a single shot picture after
each defined time interval which is programmed in
the '1SHOT REC' menu.
•
If you select '1SHOT REC' OFF, the unit will
record one picture each time the external 1SHOT
REC input is activated.
7. Press the MOVE button to choose the 1SHOT
REC option.
8. Press the SELECT button to select the desired time
of recording, 1 sec., 3 sec., 5 sec., 15 sec., 30 sec.,
60 sec. or OFF.
VEXT
In case of connecting the extemal equipment (switcher
or multiplexer), you can set the switching time of the
camera.
9. Press the MOVE button to select the VEXT option
and then press the SELECT button to select either
1 Field, 2 Field, 5 Field, 10 Field, 30 Field, or 60
Field (these are the number of fields recorded after
one VEXT pulse).
High Density Video Cassette Recorder |
Instruction Manual
|
Setting the On-Screen Display
Bosch Security Systems | 26 Feb 2003 | Draft
EN
| 17
RECORD MODE SET UP
[RECORD MODE SETUP]
ALARM REC MODE
A6H
ALARM REC TIME
30SEC
1SHOT REC
1SEC
VEXT OUT
1FIELD
SERIES REC
OFF
REPEAT:
STOP AT EOT.
[
↓
][
→
]
[MENU]END
Record
(6H-960H mode)
Record
(6H, 18H, 30H
mode)
Record
(6H-960H mode)
Record
(6H, 18H, 30H
mode)
Real Time
Record
Alarm
Record
Real Time
Record
Alarm
Record
Record Start
Alarm signal
is input
Alarm record
duration is ended
Alarm signal
is input