RE 95230-B/2021-12-01, Bosch Rexroth AG
Installation |
Analog amplifier RA 35
/48
(23)
(10)
(22)
(11)
(12)
Wiring in connector
Channel 1
Setpoint
processing
Output stage
Solenoid 1
USETPOINT
USETPOINT
approx.
5.1 kΩ
8.4V
4.0V
8.0V
4.0V
Fig� 25: Connection variant 3
Monitoring of cable break is not possible with this variant.
(23)
(10)
(22)
(11)
(12)
Wiring in connector
Channel 1
Setpoint
processing
Output stage
Solenoid 1
USETPOINT
USETPOINT
approx.
5.1 kΩ
8.4V
4.0V
8.0V
4.0V
Fig� 26: Connection variant 4
Monitoring of cable break is not possible with this variant.
(23)
(10)
(22)
(11)
(12)
Wiring in connector
Channel 1
Setpoint
processing
Output stage
Solenoid 1
ISETPOINT
ISETPOINT
approx.
5.1 kΩ
8.4V
4.0V
Fig� 27: Connection variant 5
Monitoring of cable break is not possible with this variant.
Connection variant 3
Setpoint value specification
by control
Input signal 0 ... 8.0 V.
Working range
4.0 ... 8.0 V
Connection variant 4
Setpoint value specification
by control
Input signal 0 ... 8.0 V.
Working range
0 ... 4.0 V
Connection variant 5
Setpoint value specification
by control
Input signal and working
range
0 ... 20 mA