14
General
Overview
Wiring
Adjustment
Operation
Error Analysis
Appendix
Power supply for electrical gear shifting
1
2
3
4
fuse
2A T
+
-
71
72
Vcc
GND
supply line
2 x 1 mm
2
,
length max. 10m
The power supply shown above is recommended according to the classification rules.
Alternatively, the control unit may supply the voltage for the electrical gear control:
1
2
3
4
1
2
3
4
71 72
Vcc
GND
Vcc
GND
1
2
!
!
When the control unit supplies the voltage for the electrical gear control, the power
supply is not protected by fuse. In this case, the control unit must be protected
separately (see chapter 3.1 "power supply").