De-rating factors for self-cooling 100K and forced ventilation
Height [m]
40 °C
45 °C
50 °C
55 °C
60 °C
1000
1.00
0.96
0.92
0.88
0.85
1500
0.97
0.93
0.89
0.85
0.82
2000
0.94
0.90
0.86
0.83
0.80
2500
0.90
0.86
0.83
0.79
0.77
3000
0.86
0.83
0.79
0.76
0.73
Tab. 5-3: M
0 100K
- De-rating factor f
TH 100K
for MS2N03 … 10 (standard values)
De-rating factors for water cooling
Height [m]
40 °C
45 °C
50 °C
55 °C
60 °C
1000
1.00
0.96
0.92
0.88
0.85
1500
0.99
0.95
0.91
0.87
0.84
2000
0.97
0.93
0.89
0.85
0.82
2500
0.96
0.92
0.88
0.84
0.81
3000
0.95
0.91
0.87
0.83
0.80
Tab. 5-4: M
0 100K
- De-rating Factor f
TH W
for MS2N07 … 10 (standard values)
To avoid condensation of the motors, the coolant supply temperature must be
below the saturation temperature.
fig. 4-4 "Saturation temperature depends from
ambient temperature and relative air humidity" on page 17
Bosch Rexroth AG
Operating conditions and handling
MS2N Synchronous Motors
38/95
DOK-MOTOR*-MS2N*******-IT03-EN-P
Summary of Contents for Rexroth IndraDyn S MS2N
Page 1: ...IndraDyn S MS2N Synchronous Motors Operating instructions R911347581 Edition 03 ...
Page 18: ...Bosch Rexroth AG MS2N Synchronous Motors XVI DOK MOTOR MS2N IT03 EN P ...
Page 71: ...MS2N Synchronous Motors Bosch Rexroth AG DOK MOTOR MS2N IT03 EN P 49 95 ...
Page 73: ...MS2N Synchronous Motors Bosch Rexroth AG DOK MOTOR MS2N IT03 EN P 51 95 ...
Page 85: ...MS2N Synchronous Motors Bosch Rexroth AG DOK MOTOR MS2N IT03 EN P 63 95 ...
Page 91: ...MS2N Synchronous Motors Bosch Rexroth AG DOK MOTOR MS2N IT03 EN P 69 95 ...
Page 95: ...MS2N Synchronous Motors Bosch Rexroth AG DOK MOTOR MS2N IT03 EN P 73 95 ...
Page 117: ...Notes MS2N Synchronous Motors Bosch Rexroth AG ...