Measure
Interval
Check the machine for smooth
running, vibrations and bearing
noise.
According to the specifications in the machine
maintenance plan, but at least every 1000 ope‐
rating hours.
Remove dust, chips and other
dirt from the motor housing,
cooling fins and the connections.
Depending on the degree of soiling, but after one
operating year at the latest.
Tab. 12-1:
Maintenance measures
12.5.3
Motor fan
General
There may be cases when the fan unit has to be dismounted for maintenance
measures or troubleshooting.
●
This work may only be carried out by skilled personnel.
●
When disassembling the fan unit, keep all strips, screws and nuts with
which it is attached.
In parts, the housings of the fan units consist of several screwed elements.
Only unscrew the screws that are marked as such.
Immediately after the motor has been operat‐
ed, high temperatures have to be expected
on the fan housing! Risk of burns!
CAUTION
●
Ensure adequate contact protection and wait until the motor has cooled
down.
●
Ensure that there are no combustible and flammable materials in the en‐
vironment of the hot fan.
While voltage is applied, the motor restarts
automatically, e.g., after a power failure! Risk
of injuries!
CAUTION
●
Do not stay within the danger zone of the device.
●
When working on the device, switch off the line voltage and ensure that
it cannot be reactivated.
●
Wait until the device has come to a standstill.
Rotating device!
If coming into contact with rotor or impeller,
body parts may be crushed! Risk of injuries!
WARNING
●
Protect the device against contact. Before starting work on the plant/
machine, wait until all parts have come to a standstill.
●
Do not wear jewels or loose or dangling garments when working on
moving parts.
●
Wear a cap to protect long hair.
250/265
Operation of MAD/MAF motors
MAD / MAF Asynchronous Housing Motors
Bosch Rexroth AG R911295781_Edition 11
Summary of Contents for Rexroth IndraDyn MAD100B Rexroth IndraDyn MAD100C
Page 1: ...MAD MAF Asynchronous Housing Motors Project planning manual R911295781 Edition 11 ...
Page 10: ...VIII MAD MAF Asynchronous Housing Motors Bosch Rexroth AG R911295781_Edition 11 ...
Page 14: ...4 265 MAD MAF Asynchronous Housing Motors Bosch Rexroth AG R911295781_Edition 11 ...
Page 26: ...16 265 MAD MAF Asynchronous Housing Motors Bosch Rexroth AG R911295781_Edition 11 ...
Page 152: ...142 265 MAD MAF Asynchronous Housing Motors Bosch Rexroth AG R911295781_Edition 11 ...
Page 178: ...168 265 MAD MAF Asynchronous Housing Motors Bosch Rexroth AG R911295781_Edition 11 ...
Page 182: ...172 265 MAD MAF Asynchronous Housing Motors Bosch Rexroth AG R911295781_Edition 11 ...
Page 256: ...246 265 MAD MAF Asynchronous Housing Motors Bosch Rexroth AG R911295781_Edition 11 ...
Page 268: ...258 265 MAD MAF Asynchronous Housing Motors Bosch Rexroth AG R911295781_Edition 11 ...
Page 270: ...260 265 MAD MAF Asynchronous Housing Motors Bosch Rexroth AG R911295781_Edition 11 ...
Page 274: ...Notes 264 265 MAD MAF Asynchronous Housing Motors ...
Page 275: ...Notes MAD MAF Asynchronous Housing Motors 265 265 ...