Rexroth IndraDrive
Appendix
13-19
DOK-INDRV*-HMV-*******-PR01-EN-P
Mains Filter HFD
CAUTION
Risk of damage!
⇒
Only use Rexroth filters. These filters have been
adjusted to the Rexroth supply units, inverters and
motors in the best possible way. If you use different
filters, the limit values possibly cannot be complied with.
Moreover the filters and other components of the drive
system might be destroyed.
Types
There are 2 types of mains filter for IndraDrive M drive controllers to
ensure interference suppression according to EN61800-3, class
A,
group 2 and 1 type to ensure interference suppression according to
EN61800-3, class B, group 1:
•
Type 1:
For max. 6 axis with a total motor cable length of 240 m.
•
Type 2:
For max. 15 axis with a total motor cable length of 900 m.
•
Type 3:
For max. 6 axis with a total motor cable length of 100 m.
For IndraDrive C drive controllers you only need filters Type 1 or Type 3.
Features
•
mains voltages which can be connected: 380V -15% to 480V +10%
•
appropriate mains systems: TN, TT, IT
•
maximum allowable ambient temperature: 40 °C (without derating)
resp. 55 °C (with 2% derating per °C to 40 °C)
•
filters are UL listed
Summary of Contents for Rexroth IndraDrive HMV01.1E-W0030
Page 30: ...5 2 Transport and Storage Rexroth IndraDrive DOK INDRV HMV PR01 EN P Notes ...
Page 40: ...6 10 Mechanical Mounting Rexroth IndraDrive DOK INDRV HMV PR01 EN P Notes ...
Page 88: ...9 8 Control Mains Contactor Rexroth IndraDrive DOK INDRV HMV PR01 EN P Notes ...
Page 122: ...13 22 Appendix Rexroth IndraDrive DOK INDRV HMV PR01 EN P Fig 13 25 HFD01 2 480 0026 ...
Page 123: ...Rexroth IndraDrive Appendix 13 23 DOK INDRV HMV PR01 EN P Fig 13 26 HFD02 2 480 0026 ...
Page 130: ...14 6 Index Rexroth IndraDrive DOK INDRV HMV PR01 EN P Notes ...
Page 131: ......