Description
Symbol
Unit
HMS01.1
N-W0020
HMS01.1
N-W0036
HMS01.1
N-W0054
HMS01.1
N-W0070
HMS01.1
N-W0110
Output frequency range
10)
f
out
Hz
0...1000
Power dissipation at continuous
current and continuous DC bus
power respectively
11)
P
Diss_cont
W
165.00
210.00
420.00
485.00
640.00
Latest amendment: 2017-01-23
1) 2) 3)
Housing dimension; see also related dimensional drawing
4) 5) 6)
See fig. "Air intake and air outlet at device"
7)
Observe supply voltage for motor holding brake
8)
See information on "Rated power consumption control voltage
input at U
N3
"
9)
Mains input L1, L2, L3 (for HMV and HCS only); For use on a
solidly grounded wye source only.
10)
Depending on switching frequency which was set in parameter
P‑0‑0001
11)
Plus dissipation of braking resistor and control section
Tab. 2-1:
HMS - UL ratings and dimensions
Rated power consumption control voltage input at U
N3
Plus motor holding brake and control section, plus safety option
UL ratings and dimensions
Description
Symbol
Unit
HMS01.1N-
W0150
HMS01.1N-
W0210
HMS01.1N-
W0300
HMS01.1N-
W0350
Listing in accordance with UL
standard
UL 508C
Listing in accordance with CSA
standard
C22.2 No. 274-13
UL files
E134201
Pollution degree
2
Ambient temperature range with
nominal data
T
amax
°C
40
Ambient temperature range with
reduced nominal data
T
amax_red
°C
55
Mass
m
kg
12.74
16.44
31.70
Device height
1)
H
mm
440
Device depth
2)
T
mm
262
Device width
3)
B
mm
150
200
350
Minimum distance on the top of
the device
4)
d
top
mm
80
Horizontal spacing at the device
5)
d
hor
mm
0
Minimum distance on the bottom
of the device
6)
d
bot
mm
100
Latest amendment: 2017-01-23
6/27
Ratings and dimensions
IndraDrive Drive Controllers Power Sections HMS01
Bosch Rexroth AG R911319996_Edition 08
Summary of Contents for rexroth HMS01
Page 2: ......
Page 3: ...IndraDrive Drive Controllers Power Sections HMS01 Instruction Manual R911319996 Edition 08 ...
Page 53: ......
Page 54: ......
Page 55: ......