RE 15300-WA, Version 06.2021,
Bosch Rexroth AB
Installation
53/72
Fig. 54: Vertical mounting
DD00093424
Orifice Ø 1 mm
Orifice Ø 1 mm
7.4.7 Flushing
To avoid high temperature in the motor case the heat must be removed, because
high temperature gives lower viscosity and that gives reduction in basic rated life /
service life. The motor case must be flushed when the output power exceeds the
max. values.
For calculation of required flushing, see
or contact your
Bosch Rexroth representative. The flushing oil shall be drained in the normal
drainline, see chapter
7.4.6: Draining and venting the motor
Connect the input flushing line at the lowest drain port, D1-D8 at opposite side
compared to the drain outlet in order to obtain a cross flushing flow through the
motor, see
CAUTION
High temperature in motor case!
Reduction in basic rated life/service life.
▶ Max. power without flushing:
CBm 2000 to CBm 6000
500 kW (670 hp)