Classification of biological environmental conditions
2B1
Classification of chemically active materials
2C2
Classification of mechanically active materials
2S2
Classification of mechanical ambient conditions
2M1
Tab. 10-1:
Allowed classes of ambient conditions during transport
For a better overview, some essential environmental influencing variables of
the previously mentioned classifications are listed. Unless otherwise speci‐
fied, the specified values are the values of the particular class. However,
Bosch Rexroth reserves the right to adjust these values at any time based on
future experiences or changed environmental factors.
Allowed transport conditions
Environmental factor
Symbol
Unit
Value
Temperature
T
T
°C
-20 ... +80
1)
Air humidity
(relative air humidity, cannot be com‐
bined with a quick temperature
change)
φ
%
75 (at +30 °C)
Occurrence of salt mist
Not permitted
1)
1)
Differs from DIN EN 60721-3-2
Tab. 10-2:
Allowed transport conditions
Before transport, empty the liquid coolant from the liquid-cooled
BA1N energy storage device to avoid frost damage.
50/73
Handling and transport
BA1N Kinetic Energy Buffer
Bosch Rexroth AG R911393264_Edition 01
Summary of Contents for Rexroth BA1N
Page 1: ...BA1N Kinetic Energy Buffer Project Planning Manual R911393264 Edition 01 ...
Page 30: ...24 73 BA1N Kinetic Energy Buffer Bosch Rexroth AG R911393264_Edition 01 ...
Page 32: ...26 73 BA1N Kinetic Energy Buffer Bosch Rexroth AG R911393264_Edition 01 ...
Page 40: ...34 73 BA1N Kinetic Energy Buffer Bosch Rexroth AG R911393264_Edition 01 ...
Page 52: ...46 73 BA1N Kinetic Energy Buffer Bosch Rexroth AG R911393264_Edition 01 ...
Page 62: ...56 73 BA1N Kinetic Energy Buffer Bosch Rexroth AG R911393264_Edition 01 ...
Page 74: ...68 73 BA1N Kinetic Energy Buffer Bosch Rexroth AG R911393264_Edition 01 ...
Page 77: ...Notes BA1N Kinetic Energy Buffer 71 73 ...
Page 78: ...Notes 72 73 BA1N Kinetic Energy Buffer ...